[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-676888-105":3,"detail-sidebar-cat-0-en-105":71,"doc-detail-676888-en":121},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":64,"head_meta":66,"extra_data":68,"updated_unix":70},105,"en","zvbl-series-instruction-manual-general-safety-precautions","ZVBL Series - Instruction Manual - General Safety Precautions","","Instruction Manual for the ZVBL Series zone valve box assemblies used for laboratory applications. Provides safety guidance for experienced operators handling compressed gases, including the need to read Material Safety Data Sheets for each gas, restrict installation/operation to trained personnel, and follow precautions on cylinder labels. Covers key requirements such as ventilation to prevent oxygen displacement, appropriate venting and disposal per applicable regulations, compatible materials of construction, and installation of properly vented relief devices. Includes warnings about copper acetylide hazards.",{"@graph":14,"@context":63},[15,34,54],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/zvbl-series-instruction-manual-general-safety-precautions/676888/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":48,"encodingFormat":47,"isAccessibleForFree":49,"interactionStatistic":50},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/zvbl-series-instruction-manual-general-safety-precautions/676888.png","ImageObject",300,407,{"name":42,"@type":43},"sagouaw","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":51,"interactionType":52,"userInteractionCount":22},"InteractionCounter",{"@type":53},"ViewAction",{"@type":55,"mainEntity":56},"FAQPage",[57],{"name":58,"@type":59,"acceptedAnswer":60},"How should ventilation and venting be handled to reduce risk?","Question",{"text":61,"@type":62},"Use equipment only in well-ventilated areas, vent gases to the outside away from personnel, and ensure vent outlet openings are not obstructed. Venting and disposal methods must comply with applicable federal, state, provincial, and local requirements, and relief devices should be properly installed and vented.","Answer","https://schema.org",{"og:url":32,"og:type":65,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":67,"canonical":32},"index,follow",{"doc_id":69,"site_id":7},676888,1793776967,{"code":4,"msg":72,"data":73},"success",[74,78,82,86,91,95,100,105,110,113,117],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":75,"show_sort_weight":76,"slug":77},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":79,"show_sort_weight":80,"slug":81},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":83,"show_sort_weight":84,"slug":85},"Exam",70,"exam",{"id":87,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},5,"Comic",60,"comic",{"id":92,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":93,"slug":94},6,50,"technology",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},7,"Healthcare",40,"healthcare",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},8,"Research & Report",30,"research-report",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},9,"Religion & Spirituality",20,"religion-spirituality",{"id":108,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":108,"slug":112},"World Cup","world-cup",{"id":114,"doc_module":4,"doc_module_name":25,"category_name":115,"show_sort_weight":114,"slug":116},10,"Lifestyle","lifestyle",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":119,"show_sort_weight":87,"slug":120},19,"General","general",{"code":4,"msg":72,"data":122},{"doc_id":69,"user_id":123,"nickname":42,"user_avatar":124,"doc_module":4,"category_id":92,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":125,"file_id":126,"file_url":127,"file_type":128,"file_size":129,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":130,"language":131,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":132,"faqs":133,"seo_title":134,"seo_description":12,"update_tm":70,"read_time":135},3985747862151,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Instruction Manual  \nZVBL Series  \nTHIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF BEACONMEDÆSAND IS PROVIDED TO THE PURCHASER SOLELY FOR USE IN CONJUNCTION WITH ZVBL SERIES ZONE VALVE BOXES FOR LABORATORY APPLICATIONS.  \nImportant  \nThese instructions are for experienced operators who know the general principles and safety precautions to be observed in handling compressed gases. If you are not certain you fully understand the safety precautions for handling gases, we urge you to obtain and read the Material Safety Data Sheet (MSDS) for each gas being used.  \nDo not permit untrained persons to install, operate, or maintain these manifolds. Do not attempt to install or operate these manifolds until you have read and fully understand these instructions. If you do not fully understand these instructions, contact BeaconMedæs.  \nBe sure this information reaches the operator. Your supplier has extra copies.  \nPart No.  1   \nInstruction Manual  \nZVBL Series  \n1- General Safety Precautions  \nProtect yourself and others. Read and understand the following instructions before attempting to use this equipment. Failure to understand and follow these instructions could result in serious personal injury and/or damage to equipment. Because of the many potential hazards associated with gases, read the Material Safety Data Sheet for each gas you will be using.  \n• Know and understand the physical and chemical properties of the gas being used.  \n• Observe general precautions for the use of gases.  \n• Observe safety precautions for the gas being used.  \n• Read and follow precautions on cylinder labels.  \n• Never use this equipment with gases not compatible with the materials of construction. The use of gases not compatible with the materials of construction may cause damage to equipment or injury to personnel.  \n• Many gases can cause asphyxiation by displacing oxygen in the atmosphere. Make certain the area where these manifolds are operated is well ventilated. Provide a device to warn personnel of oxygen depletion in the work area.  \n• Use this equipment only in well ventilated areas. Vent gases to the outside atmosphere, and in an area away from personnel. Be sure that venting and disposal methods are in accordance with Federal, State, Provincial and local requirements. Locate and construct vent lines to prevent condensation or gas accumulation. Be sure the vent outlet is NOT obstructed by rain, snow, ice, insects, birds, etc. Do not inter-connect vent lines; if more than one vent is needed, use separate lines.  \n• Relief devices should be installed and properly vented in all gas handling systems to protect against equipment failure and over-pressurization.  \n• Never connect this equipment to a supply source having a pressure greater than the maximum rated pressure. Refer to the Product Specifications for maximum inlet pressures.  \nWARNING – COPPER ACETYLIDE  \nDO NOT USE COPPER PIPES IN ACETYLENE SERVICE. Copper acetylide can form inside pipes made of copper or an alloy with high copper content.  \nWhen dry, copper acetylide is a heat and shock sensitive high explosive.  \n 2  Part No.  \nInstruction Manual  \nZVBL Series  \n\n| 2-Abbreviations |  |  |  |\n| --- | --- | --- | --- |\n| C | Common | OSHA | Occupational Safety & Health Administration |\n| CGA | Compressed Gas Association | PSIG | Pounds per Square Inch Gauge |\n| FT-LBS | Foot-Pounds | SCFH | Standard Cubic Feet per Hour |\n| IN-LBS | Inch-Pounds | VAC | Voltage, Alternating Current |\n| N/C | Normally Closed | VDC | Voltage, Direct Current |\n| N/O | Normally Open | PCB | Printed Circuit Board |\n| NPT | National Pipe Taper |  |  |\n| 3- Disclaimer\u003Cbr>BeaconMedæs shall not be liable for errors contained herein or incidental or consequential damages in connection with providing this manual or the use of material in this manual.\u003Cbr>4- Manufacturer Statement\u003Cbr>The information contained in this instruction booklet has been compiled by BeaconMedæs, from what it believes are authoritative sources,","cbCaihOL3YhM2Lvq","https://ap.wps.com/l/cbCaihOL3YhM2Lvq","pdf",643818,11,"English","# 1- General Safety Precautions\n## Warning – Copper Acetylide\n# 2- Abbreviations\n## OSHA, CGA, PSIG and other terms\n# 3- Disclaimer\n# 4- Manufacturer Statement\n# 5- Introduction\n# FASCIA AND LABELS – Colors, Wording and Layout","[{\"question\":\"How should ventilation and venting be handled to reduce risk?\",\"answer\":\"Use equipment only in well-ventilated areas, vent gases to the outside away from personnel, and ensure vent outlet openings are not obstructed. Venting and disposal methods must comply with applicable federal, state, provincial, and local requirements, and relief devices should be properly installed and vented.\"}]","ZVBL Series - Instruction Manual - General Safety Precautions | PDF",28]