[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-562716-105":59,"doc-detail-562716-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","z01-series-standard-1a-triacs-electrical-characteristics","Z01 Series - Standard 1A TRIACS - Electrical Characteristics","","Z01 series standard 1A TRIACs are designed for general-purpose AC switching. Core ratings specify RMS on-state current IT(RMS) of 1 A, voltage ranges of 600 to 800 V, and gate current sensitivity spanning 3 to 25 mA depending on the part. The document provides absolute maximum limits, including surge peak ITSM up to 8–8.5 A, critical dI/dt and peak gate current, plus thermal resistance values for TO-92 and SOT-223 packages. Electrical characteristics at Tj=25°C include threshold and gate trigger parameters.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/z01-series-standard-1a-triacs-electrical-characteristics/562716/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/z01-series-standard-1a-triacs-electrical-characteristics/562716.png","ImageObject",300,407,{"name":92,"@type":93},"LangkahRina","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-18","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What are the main application areas for the Z01 series TRIACs?","Question",{"text":113,"@type":114},"They are suitable for general purpose AC switching, such as home appliances (electrovalve, pump, door lock, small lamp control), and fan speed controllers.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What determines the gate current sensitivity in the Z01 series?",{"text":118,"@type":114},"Different gate current sensitivities are available (3 to 25 mA), allowing optimized performance when directly controlled from microcontrollers.",{"name":120,"@type":111,"acceptedAnswer":121},"What package options are provided and what are the corresponding thermal resistances?",{"text":122,"@type":114},"The document lists TO-92 (Z01xxA) and SOT-223 (Z01xxN) packages. Thermal resistance is specified as Rth(j-t) and Rth(j-a) for SOT-223 and Rth(j-l) and Rth(j-a) for TO-92.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},562716,1791886747,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":46,"preview_page_count":19,"preview_urls":145},962090893776,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","|   ® \u003Cbr>| Z01 Series |\n| --- | --- |\n| STANDARD | 1A TRIACS |\n\nMAIN FEATURES:  \n\n| Symbol | Value | Unit |\n| --- | --- | --- |\n| IT(RMS) | 1 | A |\n| V DRM/VRRM | 600 to 800 | V |\n| IGT (Q 1) | 3 to 25 | mA |\n\nDESCRIPTION  \nThe Z01 series is suitable for general purpose AC switching applications. They can be found in applications such as home appliances (electrovalve, pump, door lock, small lamp control), fan speed controllers, ...  \nDifferent gate current sensitivities are available, allowing optimized performances when controlled directly from microcontrollers.  \n\n| \u003Cbr>TO-92 (Z01xxA) | A2\u003Cbr>\u003Cbr>A1 | A1\u003Cbr>\u003Cbr>\u003Cbr> A2\u003Cbr>|\n| --- | --- | --- |\n|  |  | SOT-223 (Z01xxN) |\n\nABSOLUTE MAXIMUM RATINGS  \n\n| Symbol | Parameter |  |  | Value | Unit |\n| --- | --- | --- | --- | --- | --- |\n| IT(RMS) | RMS on-state current (full sine wave) | SOT-223 | Ttab = 90°C | 1 | A |\n|  |  | TO-92 | TI = 50°C |  |  |\n| ITSM | Non repetitive surge peak on-state current (full cycle, Tj initial = 25°C) | F = 50 Hz | t = 20 ms | 8 | A |\n|  |  | F = 60 Hz | t = 16.7 ms | 8.5 |  |\n| I²t | I²t Value for fusing | tp = 10 ms |  | 0.35 | ²\u003Cbr>A s |\n| dI/dt | Critical rate of rise of on-state current IG = 2 x IGT , tr ≤ 100 ns | F = 120 Hz | Tj = 125°C | 20 | A/µs |\n| IGM | Peak gate current | tp = 20 µs | Tj = 125°C | 1 | A |\n| PG(AV) | Average gate power dissipation |  | Tj = 125°C | 0.1 | W |\n| Tstg\u003Cbr>Tj | Storage junction temperature range\u003Cbr>Operating junction temperature range |  |  | -40 to + 150\u003Cbr>-40 to + 125 | °C |\n\nOctober 2001-Ed: 4 1/7  \nELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise specified)  \n\n| Symbol | Test Conditions | Quadrant |  | Z01xx |  |  |  | Unit |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  | 03 | 07 | 09 | 10 |  |\n| I GT (1) | VD = 12 V RL = 30 Ω | I - II - III\u003Cbr>IV | MAX. | 3 5 | 5 7 | 10\u003Cbr>10 | 25\u003Cbr>25 | mA |\n| V GT |  | ALL | MAX. | 1.3 |  |  |  | V |\n| VGD | VD = VDRM RL = 3.3 kΩ Tj = 125°C | ALL | MIN. | 0.2 |  |  |  | V |\n| IH (2) | IT = 50 mA |  | MAX. | 7 | 10 | 10 | 25 | mA |\n| IL | IG = 1.2 I GT | I - III-IV | MAX. | 7 | 10 | 15 | 25 | mA |\n|  |  | II |  | 15 | 20 | 25 | 50 |  |\n| dV/dt (2) | VD = 67 %V DRM gate open Tj = 110°C |  | MIN. | 10 | 20 | 50 | 100 | V/µs |\n| (dV/dt)c (2) | (dI/dt)c = 0.44 A/ms Tj = 110°C |  | MIN. | 0.5 | 1 | 2 | 5 | V/µs |\n\nSTATIC CHARACTERISTICS  \n\n| Symbol |  | Test Conditions |  |  | Value | Unit |\n| --- | --- | --- | --- | --- | --- | --- |\n| V TM (2) |  | ITM = 1.4 A tp = 380 µs | Tj = 25°C | MAX. | 1.6 | V |\n| V to (2) |  | Threshold voltage | Tj = 125°C | MAX. | 0.95 | V |\n| Rd (2) |  | Dynamic resistance | Tj = 125°C | MAX. | 400 | mΩ |\n| I\u003Cbr>I | DRM\u003Cbr>RRM | V DRM = VRRM | Tj = 25°C | MAX. | 5 | µA |\n|  |  |  | Tj = 125°C |  | 0.5 | mA |\n\nNote 1: minimum IGT is guaranted at 5% of IGT max. Note 2: for both polarities of A2 referenced to A1  \nTHERMAL RESISTANCES  \n\n| Symbol | Parameter |  |  | Value | Unit |\n| --- | --- | --- | --- | --- | --- |\n| Rth(j-t) | Junction to tab (AC) |  | SOT-223 | 25 | °C/W |\n| Rth(j-l) | Junction to lead (AC) |  | TO-92 | 60 |  |\n| Rth(j-a) | Junction to ambient | S = 5 cm² | SOT-223 | 60 | °C/W |\n|  |  |  | TO-92 | 150 |  |\n\nS = Copper surface under tab  \n2/7   \nPRODUCT SELECTOR  \n\n| Part Number | Voltage |  |  | Sensitivity | Type | Package |\n| --- | --- | --- | --- | --- | --- | --- |\n|  | 600 V | 700 V | 800 V |  |  |  |\n| Z0103MA | X |  |  | 3 mA | Standard | TO-92 |\n| Z0103MN | X |  |  | 3 mA | Standard | SOT-223 |\n| Z0103SA |  | X |  | 3 mA | Standard | TO-92 |\n| Z0103SN |  | X |  | 3 mA | Standard | SOT-223 |\n| Z0103NA |  |  | X | 3 mA | Standard | TO-92 |\n| Z0103NN |  |  | X | 3 mA | Standard | SOT-223 |\n| Z0107MA | X |  |  | 5 mA | Standard | TO-92 |\n| Z0107MN | X |  |  | 5 mA | Standard | SOT-223 |\n| Z0107SA |  | X |  | 5 mA | Standard | TO-92 |\n| Z0107SN |  | X |  | 5 mA | Standard | SOT-223 |\n| Z0107NA |  |  | X | 5 mA | Standard | TO-92 |\n| Z0107NN |  |  | X | 5 mA | Standard | SOT-223 |\n| Z0109MA | ","cbCaieABR43GjX2O","https://ap.wps.com/l/cbCaieABR43GjX2O","pdf",116968,"English","# Z01 Series Overview\n## Main Features and Applications\n## Absolute Maximum Ratings\n## Electrical Characteristics\n## Static Characteristics\n## Thermal Resistances\n## Product Selector\n## Ordering Information\n## Other Information","[{\"question\":\"What are the main application areas for the Z01 series TRIACs?\",\"answer\":\"They are suitable for general purpose AC switching, such as home appliances (electrovalve, pump, door lock, small lamp control), and fan speed controllers.\"},{\"question\":\"What determines the gate current sensitivity in the Z01 series?\",\"answer\":\"Different gate current sensitivities are available (3 to 25 mA), allowing optimized performance when directly controlled from microcontrollers.\"},{\"question\":\"What package options are provided and what are the corresponding thermal resistances?\",\"answer\":\"The document lists TO-92 (Z01xxA) and SOT-223 (Z01xxN) packages. Thermal resistance is specified as Rth(j-t) and Rth(j-a) for SOT-223 and Rth(j-l) and Rth(j-a) for TO-92.\"}]","Z01 Series - Standard 1A TRIACS - Electrical Characteristics | PDF",1791809576,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/1f413db6c00547444e0db28aa635ddbc.webp",983,1390,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/0c51d9d283aa0d0dce8fa7cdaa36acc6.webp",982,1389,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/30db770bbe2b64b44e2c0904f2c9fc3c.webp",981,1387,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d5bc783bbf54a744e72dfeec74cb1f67.webp",980,1386]