[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663444-105":59,"doc-detail-663444-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","xdc-cbl-stnd-h-001-013-110kv-underground-cable-drawings-combined-copy-standard-3rd-party-crossing-125mm","XDC-CBL-STND-H-001-013-110kV Underground Cable Drawings combined copy - Standard 3rd Party Crossing 125mm","","Standard underground cable drawing set for 110kV systems, focused on a 3rd party crossing arrangement using 125mm ducts. Includes an index sheet listing multiple drawing sheets and provides drawing numbers, revision information, first issue details, and scale/size metadata. Technical content specifies duct layouts (including above flat and trefoil formations), minimum burial depth, finished surface levels, concrete bedding and rapid-hardening concrete grades, marker tapes, warning tape, steel plate requirements, spacings, clearances, and installation guidance notes aligned to relevant standards.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/xdc-cbl-stnd-h-001-013-110kv-underground-cable-drawings-combined-copy-standard-3rd-party-crossing-125mm/663444/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/xdc-cbl-stnd-h-001-013-110kv-underground-cable-drawings-combined-copy-standard-3rd-party-crossing-125mm/663444.png","ImageObject",300,407,{"name":92,"@type":93},"asda1da","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What cable duct size and crossing arrangement does the document standard cover?","Question",{"text":112,"@type":113},"The document standard covers a 3rd party crossing arrangement using 125mm duct configurations, with additional layout variants shown for above-ground formations.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What installation depth and surface level requirements are specified?",{"text":117,"@type":113},"It specifies a minimum burial depth (450mm) and identifies finished surface level references used to control the final installation geometry.",{"name":119,"@type":110,"acceptedAnswer":120},"Which materials and markings are required for the crossing?",{"text":121,"@type":113},"The notes require concrete placement with rapid-hardening wet mix grade, steel plates over the ducts, and the use of marker strips plus yellow warning tape as part of the warning/identification system.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663444,1793227782,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":31,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},3985747861852,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","2  \n3  \n4  \n5  \n6  \n7  \n8  \n1  \n\n| A  \u003Cbr>B  \u003Cbr>C  \u003Cbr>D  \u003Cbr>E  \u003Cbr>F   | STANDARD 110kV CABLE DRAW  \u003Cbr>STANDARD CROSSING ABOV  \u003Cbr>3rd PARTY SERVICE FOR 125mm   |  |  |  | INGS  \u003Cbr>E  \u003Cbr> DUCTS   |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  | EirGrid plc  \u003Cbr>EIRGRID  \u003Cbr>The Oval,160 Shelbourne Road,   | STANDARD 110kV CABLE DRAWINGS   |  |\n|  |  |  |  |  | Ballsbridge,Dublin 4,Ireland  \u003Cbr>Telephone:  \u003Cbr>+35316771700  \u003Cbr>+35316615375  \u003Cbr>Fax:  \u003Cbr>info@eirgrid.com  \u003Cbr>Email:  \u003Cbr>Web:  \u003Cbr>www.eirgrid.com   |  |  |\n|  |  |  |  |  |  | DRAWING TTLE  \u003Cbr>STANDARD 3rd PARTY CROSSING  \u003Cbr>125mm  \u003Cbr>INDEX SHEET   |  |\n|  |  |  |  |  | COPYRIGHT O EirGrid plc  \u003Cbr>Allrights reserved.No port of this work may be modified or reproduced or  \u003Cbr>copied in any form or by any means -graphic,electronic or mechanical,  \u003Cbr>including photocopying,recording,toping or information and retrieval system,or   \u003Cbr>used for any purpose other than its designated purpose,without the written  \u003Cbr>permission of EirGrid plc   |  |  |\n|  |  |  |  |  |  | SIZE A3  \u003Cbr>No of Shts 3   | SCALE N/A   |\n|  |  | 00   | FIRST ISSUE   | CF  \u003Cbr>09/03/2020  \u003Cbr>DG  \u003Cbr>DA   |  | DRAWING NUMBER  \u003Cbr>XDC-CBL-STND-H-001   | REV  \u003Cbr>SHEET  \u003Cbr>00  \u003Cbr>001   |\n|  |  | REV   | DESC   | CHECKED APPROVED DATE  \u003Cbr>DRAWN   |  |  |  |\n\n\n| DRAWING No.   | SHEET No.   | DESCRIPTION   | REVISION No.   |\n| --- | --- | --- | --- |\n| XDC-CBL-STND-H-001   | 001   | STANDARD 3rd PARTY CROSSING 125mm INDEX SHEET   | 00   |\n| XDC-CBL-STND-H-001   | 002   | STANDARD 3rd PARTY CROSSING ABOVE IN FULL FLAT FORMATION   \u003Cbr>25mm HV DUCTS   | 00   |\n| XDC-CBL-STND-H-001   | 003   | STANDARD 3rd PARTY CROSSING ABOVE IN TREFOIL FORMATION 12  \u003Cbr>5mm HV DUCTS   | 00   |\n\n125mm Q.D.DUC⁷  \n125mm 0.D.  DUC  \n\n| 4  \u003Cbr>1  \u003Cbr>7  \u003Cbr>8  \u003Cbr>6  \u003Cbr>5  \u003Cbr>3  \u003Cbr>2   |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| A  \u003Cbr>B  \u003Cbr>C  \u003Cbr>D  \u003Cbr>E  \u003Cbr>F   | 950   | MAX 150  \u003Cbr>FINISHED SURFACE LEVEL  \u003Cbr>又   |  |  |  |  | MINIMUM BURIAL  \u003Cbr>DEPTH 450mm AS PER  \u003Cbr>HSA CODE OF PRACTICE   |  | 6 No.*STEEL PLATES &   | DUCTS LAID IN CBGM B(CL.822)  \u003Cbr>YELLOW MARKER  \u003Cbr>WARNING TAPE  \u003Cbr>OF TII SPECIFICATION FOR ROADWORKS   |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  | 125mm 0.D.DUCT   |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  | 1:6 GRADIENT   |  |  |  | EXISTING GROUND   |  |  | EXISTING CULVERT/SERVICE  \u003Cbr>1:6 GRADIENT   |  |  |  |  |\n|  | RAPID HARDENING WET MIX CONCRETE GRADE   \u003Cbr>NOTES:  \u003Cbr>1.ALL PRODUCTS AND MATERIALS TO BE   \u003Cbr>CONSTRUCTION TO COMPLY WITH EIRGRI  \u003Cbr>SPECIFICATION,ESBN STANDARDS,TIl S  \u003Cbr>ROAD WORKS AND ALL RELEVANT IRISH  \u003Cbr>BRITISH STANDARDS.  \u003Cbr>2.300mm MINIMUM VERTICAL AND HORIZO  \u003Cbr>TO BE OBSERVED BETWEEN CABLE DUC  \u003Cbr>SERVICES(e.g.GAS PIPES,WATER MAIN  \u003Cbr>IN THE CASE OF HIGH RISK 3rd PARTY  \u003Cbr>CLEARANCES MAY BE REQUIRED.DESIGN  \u003Cbr>EIRGRID AND 3rd PARTY SERVICE OWNE  \u003Cbr>3.STEEL PLATES MUST COVER DUCTS.NO  \u003Cbr>REQUIRED HOWEVER STANDARD DIMENSI  \u003Cbr>AN OVERLAP.SPACING OF 25mm TO B  \u003Cbr>BETWEEN STEEL PLATES TO PREVENT T  \u003Cbr>STRAY CURRENT.  \u003Cbr>4.THE MINIMUM CLEARANCE BETWEEN ALL  \u003Cbr>COMMUNICATION DUCTS IS 75mm,BUT I  \u003Cbr>MAY BE REQUIRED IN ORDER TO ACHIE  \u003Cbr>RATING(TO BE CONFIRMED BY DESIGNE  \u003Cbr>CALCULATIONS).  \u003Cbr>5.DRAWING IS INDICATIVE ONLY,TO BE U  \u003Cbr>DESIGN OF THE RELEVANT INFRASTRUCT  \u003Cbr>6.TEMPLATES ARE TO BE USED AT 5m IN  \u003Cbr>DUCT INSTALLATION IN CBGM.PRE-MAD  \u003Cbr>CONCRETE SPACERS TO BE USED DURI  \u003Cbr>INSTAIATION IN WET CONCRFTF  \u003Cbr>7.MINIMUM BURIAL DEPTH IS 450mm.  \u003Cbr>8.HAND DIG WITHIN 500mm OF EXISTING   \u003Cbr>9.WHERE AN EARTH CONTINUITY_CONDUCT  \u003Cbr>REQUIRED,A MIN 63mm DUCT TO BE I  \u003Cbr>OF PHASE DUCT.   |  |  | C25/30  \u003Cbr>RED MARKER STRIP  \u003Cbr>FULL F  \u003Cbr>UTILISED DURING  \u003Cbr>FOR C  \u003Cbr>YELLOW MARKER WARNING TAPE  \u003Cbr>D FUNCTIONAL  \u003Cbr>PECIFICATION FOR  \u003Cbr>EXISTING SERVICE MARKER STRIP  \u003Cbr>(","cbCaippVStBMYHuf","https://ap.wps.com/l/cbCaippVStBMYHuf","pdf",7086666,"English","# Drawing Index Sheet\n## Standard 3rd Party Crossing 125mm\n## Standard 3rd Party Crossing Above in Full Flat Formation - 25mm HV Ducts\n## Standard 3rd Party Crossing Above in Trefoil Formation - 125mm HV Ducts","[{\"question\":\"What cable duct size and crossing arrangement does the document standard cover?\",\"answer\":\"The document standard covers a 3rd party crossing arrangement using 125mm duct configurations, with additional layout variants shown for above-ground formations.\"},{\"question\":\"What installation depth and surface level requirements are specified?\",\"answer\":\"It specifies a minimum burial depth (450mm) and identifies finished surface level references used to control the final installation geometry.\"},{\"question\":\"Which materials and markings are required for the crossing?\",\"answer\":\"The notes require concrete placement with rapid-hardening wet mix grade, steel plates over the ducts, and the use of marker strips plus yellow warning tape as part of the warning/identification system.\"}]","XDC-CBL-STND-H-001-013-110kV Underground Cable Drawings combined copy - Standard 3rd Party Crossing 125mm | PDF",126]