[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662152-105":59,"doc-detail-662152-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","world-k-series-electromagnetic-brake-motors-operating-manual","World K Series - Electromagnetic Brake Motors - Operating Manual","","Operating manual for ORIENTAL MOTOR World K Series electromagnetic brake motors. Provides safety precautions for installation and operation, including flammable/corrosive environment avoidance, electrical shock prevention via grounding/class I setup, correct handling of motor lead wires, qualified installer requirements, and warnings about high case temperatures and automatic restart after thermal protection. Details package contents, motor–capacitor combination verification, relevant model/capacitor tables, certification standards, and installation conditions such as temperature, humidity, altitude, vibration, and overvoltage/pollution classification.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/world-k-series-electromagnetic-brake-motors-operating-manual/662152/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/world-k-series-electromagnetic-brake-motors-operating-manual/662152.png","ImageObject",300,407,{"name":92,"@type":93},"Putri","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What safety precautions are required during installation?","Question",{"text":112,"@type":113},"Do not install in places with flammable or corrosive gas. Fix motor lead wires so they do not move and avoid applying pressure to them. Ground the motor/class I housing properly and use a qualified installer.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How should operation temperature and warnings be handled?",{"text":117,"@type":113},"The motor case temperature may exceed 70°C depending on operating conditions. If the motor is accessible during operation, attach the provided warning label so it is clearly visible. Always turn off the power before checks or work, noting thermally protected motors may restart automatically when temperature drops.",{"name":119,"@type":110,"acceptedAnswer":120},"What must be checked when the product arrives and how are installation conditions defined?",{"text":121,"@type":113},"Verify that the received motor and capacitor combination matches the name plates and the corresponding model/capacitor table. Install in an indoor location meeting ambient temperature, humidity, altitude, vibration, gas exposure, and overvoltage/pollution/class I equipment conditions to avoid damage.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662152,1793202432,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":29,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},962085571259,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Thank you for purchasing ORIENTAL MOTOR products. Please read this operating manual thoroughly before installing and operating the motor, and always keep the manual where it is readily accessible.  \n\u003CTable of contents> 1. Precautions............................................... Page 1  \n2. Checking the package contents ............... Page 1  \n3. Installation ................................................ Page 2  \n4. Connection and Operation........................Page 4  \nHM-9097-11  \nWorld K Series  \nElectromagnetic Brake Motors  \nOPERATING MANUAL  \n5.Time Rating ..................................................... Page 5  \n6. Locked rotor burnout protection...................... Page 5  \n7. Troubleshooting .............................................. Page 6  \n1. Precautions  \n1.1 Precautions for Installation  \n• Do not use in a place where there is flammable gas and/or corrosive gas.  \n• When installing the motor into your equipment, ensure that the motor lead wires are fixed and do not move.  \nIn addition, do not apply any pressure to these lead wires.  \n• The motor is Class І equipment. Install the motor so as to avoid contact with hands, or ground it to prevent the risk of electric shock. Dieser Motor ist in Geräten mit Schutzklasse I zu verwenden.  \nDer Motor ist so einzusetzen, dass er nicht berührt werden kann, bzw. er ist zu erden, um Stromschläge zu verhindern.  \n• The motor housing must be mounted with a screw and spring washer to the ground point of the equipment.  \nDie Gehäuse der Motore sind mit einer Schraube und Zahnscheibe sichermit dem geerdeten Gehäuse des Gerätes zu verbinden.  \n• Installation must be performed by a qualified installer.  \n1.2 Precautions for Operation  \n• The Motor case temperature can exceed 70°C (depending on operation conditions) . In case motor is accessible during operation, please attach the following warning label so that it is clearly visible.  \n• Always turn off the power to the motor before conducting checks or performing work on the motor. Thermally protected motors will restart automatically when motor temperature falls bellow a certain level.  \n• Do not use the electromagnetic brake of the motor as a safety brake.  \nIn the event the overheat protection device (thermal protector) is triggered, the load will not be held in position. A safety device should be provided separately.  \n2. Checking the package contents  \nWarning label  \n2.1 Checking the contents  \nMake sure that you have received all of the items listed below.  \nIf an accessory is missing or damaged,contact the nearest ORIENTAL MOTOR office.• Motor.......................... 1 • Capacitor cap..........................1 (for only single-phase motors )  \n• Capacitor.................... 1 (for only single-phase motors ) • This operating manual ............1  \n2.2 Checking the product name and motor-capacitor combination  \nThis product comes in a combined set consisting of a motor and a capacitor. When the product first arrives, check the name plates to confirm that you have received the correct motor and capacitor combination.  \n􀂄 100V/110V/115V type  \n\n| Model | Motor model | Capacitor Model |\n| --- | --- | --- |\n| 5RK60GU-AWMJ | 5RK60GU-AWM | CH250CFAUL2 |\n| 5RK60GU-AWMU |  | CH200CFAUL2 |\n| 5RK90GU-AWMJ | 5RK90GU-AWM | CH350CFAUL |\n| 5RK90GU-AWMU |  | CH300CFAUL2 |\n\n􀂄 200V/220V/230V type  \n\n| Model | Motor model | Capacitor Model |\n| --- | --- | --- |\n| 5RK60GU-CWMJ | 5RK60GU-CWM | CH60BFAUL |\n| 5RK60GU-CWME |  | CH50BFAUL |\n| 5RK90GU-CWMJ | 5RK90GU-CWM | CH80BFAUL |\n| 5RK90GU-CWME |  | CH70BFAUL |\n| 5IK60GU-SWM | 5IK60GU-SWM | − |\n| 5IK90GU-SWM | 5IK90GU-SWM | − |\n\nMotors are recognized by UL and certified by VDE or DEMKO.  \nRecognized name and certified name are motor model name.  \n• Standards UL 1004-1, UL 1004-3, CSA C22.2 No. 100, CSA C22.2 No. 77, EN 60950-1 or EN 62368-1  \nCertification Body Motor: UL File No. E64197  \nVDE  \nDEMKO  \nCapacitor: UL FileNo. E83671 (CYWT2),  \nVDE Licence No. 112847 (for only ","cbCaipHHpkM85h55","https://ap.wps.com/l/cbCaipHHpkM85h55","pdf",283039,"English","# Precautions\n## Precautions for Installation\n## Precautions for Operation\n# Checking the package contents\n## Checking the contents\n## Checking the product name and motor-capacitor combination\n# Installation\n## Installation conditions\n## Mounting the motor","[{\"question\":\"What safety precautions are required during installation?\",\"answer\":\"Do not install in places with flammable or corrosive gas. Fix motor lead wires so they do not move and avoid applying pressure to them. Ground the motor/class I housing properly and use a qualified installer.\"},{\"question\":\"How should operation temperature and warnings be handled?\",\"answer\":\"The motor case temperature may exceed 70°C depending on operating conditions. If the motor is accessible during operation, attach the provided warning label so it is clearly visible. Always turn off the power before checks or work, noting thermally protected motors may restart automatically when temperature drops.\"},{\"question\":\"What must be checked when the product arrives and how are installation conditions defined?\",\"answer\":\"Verify that the received motor and capacitor combination matches the name plates and the corresponding model/capacitor table. Install in an indoor location meeting ambient temperature, humidity, altitude, vibration, gas exposure, and overvoltage/pollution/class I equipment conditions to avoid damage.\"}]","World K Series - Electromagnetic Brake Motors - Operating Manual | PDF",15]