[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-489175-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-489175-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","wood-flooring-specification-template-document-typical-specification","Wood Flooring Specification Template Document - Typical Specification","","Wood flooring specification template detailing requirements for American engineered walnut flooring for a site or project. Specifies substrate conditions, moisture limits, board construction and grading standards, edge and finish details, adhesive and laying method per relevant BS/EN codes, and expansion gap design rules. Covers DPM provisions, performance criteria including load bearing, reaction to fire, and slip resistance testing. Also defines concrete/screed preparation checks, primer guidance, and protection methods during installation and completion.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/wood-flooring-specification-template-document-typical-specification/489175/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/wood-flooring-specification-template-document-typical-specification/489175.png","ImageObject",300,407,{"name":42,"@type":43},"asba","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-23","2026-10-01",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What substrate moisture level is required before laying the wood flooring?","Question",{"text":63,"@type":64},"The substrate should be clean and dry with a moisture content of less than 10%. For concrete/screed, the relative humidity above the substrate tested per BS 8201 Appendix A should have a maximum of 75%.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What expansion gaps must be provided around the perimeter and where the floor meets other materials?",{"text":68,"@type":64},"A 10mm expansion gap is required around the perimeter and/or where the wood flooring meets differing materials. Additionally, 8mm expansion gaps should be designed into the floor at a minimum of every 6–8 Lm in any one direction, and construction joints should not be bridged.",{"name":70,"@type":61,"acceptedAnswer":71},"What performance and safety requirements are specified for the flooring?",{"text":72,"@type":64},"Load bearing must conform to BS 6399-1:1966 Table 1 Section 3, reaction to fire must meet EN 13501-1 Dn s1, and slip resistance must be tested to BS 7967-2:2002 (Pendulum Test) aiming for LOW slip risk in dry and MODERATE risk in wet conditions.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},489175,1792959010,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":97,"preview_page_count":26,"preview_urls":144},3985747872567,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Wood Flooring Specification Template Document  \nThe details below would be a typical specification for our American Engineered Walnut Flooring. The word document you can download here can be saved on your own computer, amended and copied and pasted to any specification, bills of quantity or as part of the design build contract. To get the full details of any product just enter the product code number like 124 or 738 in the search baron the web site and it will take you to the product details and product data sheet which you can download. Our Industrial finishes are the best.  \nOur grading and details of type testing of our hardwood floors can be found here.  \nTypical Specification used by NBS  \nK21 Wood strip / board / board fine flooring / linings-to be read with Preliminaries/General conditions.  \nTypes of Flooring  \n110 WOOD BOARD FLOORING to   site or project name Substrate: Cement and Sand Screed  \n• Preparation: Clean, Dry substrate with a moisture content of less than 10%  \n• Wood boards: Free from decay, through splits and insect attack (including ambrosia beetle damage, unless permitted in the class/ grade specified) .  \n• Manufacturer: The Solid Wood Flooring Company-Tel: 01666 504015 / mobile:  \n07831 680 206 / Email: info@thesolidwoodflooringcompany.com  \nProduct reference: E502 (this is an example details taken from the product data sheet and you add the individual product in place of the red text)  \n• Species: Engineered American Walnut  \n• Appearance class/ Grade: To BS EN 942, ABCD Grade with sound knots up to 50mm permitted  \n• Board size: 190mm wide 21mm thick with a solid 6mm top layer in lengths of 1860mm with two boards 600mm plus  \n• Edges: Long edges tongued & grooved, Ends tongued & grooved with micro bevel  \n• Finish: Finished in Hard Wax oil-as delivered  \n• Moisture content at time of laying: 6-8% .  \nLaying: Flooring to be fitted in accordance with BS 8201:2011 Code of Practice for Flooring of Timber, Timber Products and wood-based panel products  \n• Pattern: As laid.  \n• Adhesive: SW890 adhesive. Solid bed using 3mm to 5mm notched trowel  \n• Method of finishing: Prefinished boards with builders clean.  \n• Other requirements:  \n• Expansion gaps: A 10mm expansion is gap required around the perimeter of the floor and/or where the wood flooring meets differing materials. 8mm expansion gaps should be designed into the floor at a minimum of 6-8 Lm in any one direction and construction joints should not be bridged.  \n• DPM: As designed into the floor  \n• Performance:  \nLoad bearing: Conform to BS 6399-1: 1966 table 1 section 3  \nReaction to fire: Perform to EN 13501-1 Dn s1  \n• Slip Resistance: Tested to BS 7967-2: 2002 (Pendulum Test) and achieve LOW Slip risk in the DRY and MODERATE risk in the WET  \nPreparation of Substrates  \n210 DRYNESS OF CONCRETE/ SCREED SUBSTRATES  \nRelative humidity above substrate when tested with a hygrometer to BS 8201, Appendix A  \n(maximum): 75% .  \n• Test points: All corners, around perimeter, and random points over area being tested.  \n• Drying aids: Turned off for not less than 4 days before testing.  \n220 CONCRETE/ SCREED SUBSTRATES  \nFinished surface: Smooth, even, and free from abrupt changes in level. Apply suitable  \nsmoothing compound, as necessary.  \n• Surface regularity when checked with a 3 m straightedge with 3 mm feet at each end, placed  \n• anywhere on the surface: No gap greater than 6 mm, and straightedge not obstructed by the  \n• substrate.  \n• Primer: If recommended by adhesive manufacturer, apply and allow to dry thoroughly before laying flooring.  \n590 PROTECTION  \nProtective covering: Submit proposals-Remove at completion. Always use a breathable membrane and hardboard on top to fully protect your floor.","cbCaidSl8HWWJynw","https://ap.wps.com/l/cbCaidSl8HWWJynw","pdf",142503,"English","# Types of Flooring\n## Preparation of Substrates\n### 210 Dryness of Concrete/Screed Substrates\n### 220 Concrete/Screed Substrates\n## Protection","[{\"question\":\"What substrate moisture level is required before laying the wood flooring?\",\"answer\":\"The substrate should be clean and dry with a moisture content of less than 10%. For concrete/screed, the relative humidity above the substrate tested per BS 8201 Appendix A should have a maximum of 75%.\"},{\"question\":\"What expansion gaps must be provided around the perimeter and where the floor meets other materials?\",\"answer\":\"A 10mm expansion gap is required around the perimeter and/or where the wood flooring meets differing materials. Additionally, 8mm expansion gaps should be designed into the floor at a minimum of every 6–8 Lm in any one direction, and construction joints should not be bridged.\"},{\"question\":\"What performance and safety requirements are specified for the flooring?\",\"answer\":\"Load bearing must conform to BS 6399-1:1966 Table 1 Section 3, reaction to fire must meet EN 13501-1 Dn s1, and slip resistance must be tested to BS 7967-2:2002 (Pendulum Test) aiming for LOW slip risk in dry and MODERATE risk in wet conditions.\"}]","Wood Flooring Specification Template Document - Typical Specification | PDF",1790821043,[145,149],{"page_no":22,"url":146,"width":147,"height":148},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/6a8bc376f31b99f85466520560e1f7b1.webp",983,1390,{"page_no":26,"url":150,"width":151,"height":152},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/32c66e8beaa8834fb01c0fa01dd7b28e.webp",982,1388]