[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-662745-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-662745-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","wet-welldry-well-pumping-stations-chapter-ii-reference-drawings","WET WELL/DRY WELL PUMPING STATIONS - CHAPTER II - Reference Drawings","","Reference drawings for wet well and dry well pumping stations used by the Anne Arundel County, Maryland Department of Public Works. The chapter compiles an index of civil, structural, mechanical, and electrical drawing sheets, each identified by drawing number, covering site and plan details, piping and bedding, building sections, wet well and emergency connection vaults, odor and chemical control systems, and electrical and control diagrams. Includes publication and revision dates.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/wet-welldry-well-pumping-stations-chapter-ii-reference-drawings/662745/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/wet-welldry-well-pumping-stations-chapter-ii-reference-drawings/662745.png","ImageObject",300,407,{"name":42,"@type":43},"ahduag","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What document section is provided here?","Question",{"text":62,"@type":63},"Chapter II, Reference Drawings, for Wet Well/Dry Well Pumping Stations.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What types of drawings are included in the index?",{"text":67,"@type":63},"Civil, structural, mechanical, and electrical drawing sheets, each listed with a drawing number.",{"name":69,"@type":60,"acceptedAnswer":70},"Are publication and revision dates included?",{"text":71,"@type":63},"Yes. The document shows Published and Revised dates (e.g., Published: 6/11 and Revised: 04/24).","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},662745,1793222226,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":79,"read_time":144},3985747870414,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","ANNE ARUNDEL COUNTY MARYLAND DEPARTMENT OF PUBLIC WORKS  \nCHAPTER II  \nREFERENCE DRAWINGS  \nfor  \nWET WELL/DRY WELL PUMPING STATIONS  \nApril 2024  \nPublished: 6/11 Revised: 04/24  \nREFERENCE DRAWINGS FOR  \nWET/DRY WELLAND SUBMERSIBLE PUMPING STATIONS  \nINDEX OF DRAWINGS  \nDESCRIPTION  DRAWING NO.  \n1. Civil—Plan and Details PS-C-1  \n2. Civil—Sediment and Erosion PS-C-2  \n3. Site Paving Detail PS-Cl-1  \n4. Typical Cantilever Gate PS-Cl-2  \n5. Pump Station Access Road Detail PS-Cl-3  \n6. DIP Pipe Bedding Detail (inside of SPS fenceline) PS-Cl-4  \n7. HDPE and PVC Pipe Bedding Detail (inside of SPS fenceline) PS-C1-4A  \n8. Mowing Strip Detail PS-Cl-5  \n9. MJ Adapter Detail DIP to HDPE PS-Cl-6  \n10. Pipe Bollard Detail PS-Cl-7  \n11. Removable Pipe Bollard Detail PS-C1-7A  \n12. Plan—Pump Station Building PS-A1-1  \n13. Building Section 1 PS-A1-2  \n14. Building Section 2 PS-A1-3  \n15. Building Section 3 PS-A1-4  \n16. Building Section 4 PS-A1-5  \n17. Section 5 PS-Al-6  \n18. Section 6 PS-Al-7  \n19. Eave Detail PS-Al-8  \n20. Rake Detail PS-Al-9  \n21. Detail—Generator Exhaust Pipe Penetration PS-Al-10  \nPublished: 6/11 Revised: 04/24  \n22. Removable Louver Detail  \n23. Structural—Plans and Details  \n24. Exterior Wall Footing Section  \n25. Thickened Slab Detail  \n26. Typical Section Wet/Dry Well and Emergency Connection Vault  \n27. Anchor Clip Angle Detail  \n28. Typical Section Wet Well  \n29. Wet Well Base (Cast in Place)  \n30. Structural Note  \n31. Grating Detail  \n32. Ladder and Safety Extension Pole Detail  \n33. Grab Rail  \n34. Removable Bar Screen—Plan View  \n35. Removable Bar Screen—Section  \n36. Bar Screen—Section  \n37. Pipe Penetration Support Detail  \n38. Fuels Oil Trench Detail  \n39. Equipment Support Pad Detail  \n40. Pump Support Pad  \n41. Soleplate Details  \n42. Odor Filter Piping Trench Detail  \n43. Mechanical Plan, Sections and Pump Curves – Wet/Dry Well  \n44. Mechanical Plan, Sections and Pump Curves-Submersible  \n45. Pump and System Curve  \n46. Mechanical Plan and Details – Wet/Dry Well  \nPS-Al-11  \nPS-S-1  \nPS-S1-1  \nPS-S1-2  \nPS-S1-3  \nPS-S1-3A  \nPS-S1-4  \nPS-S1-6  \nPS-S1-7  \nPS-S2-1  \nPS-S2-2  \nPS-S2-2A  \nPS-S2-3A  \nPS-S2-3B  \nPS-S2-3C  \nPS-S2-4  \nPS-S2-5  \nPS-S2-6  \nPS-S2-6A  \nPS-S2-6B  \nPS-S5-2  \nPS-M-1A  \nPS-M-1B  \nPS-M1-1  \nPS-M-2A  \nPublished: 6/11 Revised: 04/24  \n47. Mechanical Plan and Details – Submersible PS-M-2B  \n48. Pump Station (Top Slab) Plan View Wet/Dry Well PS-M1-2A  \n49. Pump Station and Valve Vault (Top Slab) Plan – Submersible PS-M1-2B  \n50. Pump Station (Top Slab Removed) Plan – Wet/Dry Well PS-M1-3A  \n51. Pump Station (Top Slab Removed) Plan – Submersible PS-M1-3B  \n52. Pump Station (Below Grating) Plan – Submersible PS-M1-3C  \n53. Service Area Design Flows Chart PS-M1-4  \n54. Pump Station Section Wet/Dry Well with Emergency Connection Vault PS-M1-5A  \n55. Valve Vault Section – Submersible PS-M1-5B  \n56. Pump Station Section – Wet/Dry Well PS-M1-6A  \n57. Wet Well/Valve Vault Section – Submersible PS-Ml-6B  \n58. Level Transducer Installation PS-M1-7  \n59. Lifting Eye Detail PS-M1-8  \n60. Lifting Plate Detail PS-M1-9  \n61. Pump Station Building Mechanical Plan PS-M2-1  \n62. Dry Well—Mechanical Plan Wet/Dry Well PS-M2-2A  \n63. Wet Well—Mechanical Plan Submersible PS-M2-2B  \n64. Tie Rod Detail PS-M2-3  \n65. Horizontal Pipe Pressure Gauge Detail PS-M2-4  \n66. Level Transducer Schematic PS-M2-5  \n67. Pipe Support Details PS-M2-7  \n68. Mechanical – Ferrous Sulfate Bioxide PS-M3  \n69. Chemical Odor Control System Section PS-M3-1  \n70. Chemical Odor Control System Section PS-M3-2  \n71. Chemical Odor Control System Section PS-M3-3  \n72. Chemical Odor Control System Nomenclature PS-M3-4  \nPublished: 6/11 Revised: 04/24  \n73. Carbon Canister Odor Control System  \n74. Heating/Ventilation Schedules  \n75. Supply Fan Wet/Dry Well  \n76. Exhaust Fan Drywell  \n77. Pump Station Building Electrical Plan  \n78. Wet Well – Electrical Plan Wet/Dry Well  \n79. Dry Well – Electrical Plan Wet/Dry Well  \n80. Wet Well Electrical ","cbCaidK3knyuxb6e","https://ap.wps.com/l/cbCaidK3knyuxb6e","pdf",7300040,122,"English","# Index of Drawings\n## Civil - Plan and Details\n## Mechanical - Plans, Sections and Pump Curves\n## Electrical - Plans, Schedules and Control Diagrams\n## Odor Control Systems - Mechanical and P&ID","[{\"question\":\"What document section is provided here?\",\"answer\":\"Chapter II, Reference Drawings, for Wet Well/Dry Well Pumping Stations.\"},{\"question\":\"What types of drawings are included in the index?\",\"answer\":\"Civil, structural, mechanical, and electrical drawing sheets, each listed with a drawing number.\"},{\"question\":\"Are publication and revision dates included?\",\"answer\":\"Yes. The document shows Published and Revised dates (e.g., Published: 6/11 and Revised: 04/24).\"}]","WET WELL/DRY WELL PUMPING STATIONS - CHAPTER II - Reference Drawings | PDF",307]