[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663705-105":59,"doc-detail-663705-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","wc-2-structural-integrity-test-scope","WC-2 Structural Integrity Test - Scope","","WC-2 Structural Integrity Test establishes specific load values to evaluate the structural integrity of an architectural wall cabinet test specimen under defined test conditions. The method clarifies that the selected loads are not intended to represent service loads or normal usage. It provides guidance for architects, design professionals, and manufacturers to judge the assembly’s serviceability performance, integrity of joinery and materials, and relevance of measured test data without determining hardware serviceability or useful life.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/wc-2-structural-integrity-test-scope/663705/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/wc-2-structural-integrity-test-scope/663705.png","ImageObject",300,407,{"name":92,"@type":93},"Connor ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of the WC-2 structural integrity test method?","Question",{"text":112,"@type":113},"It determines specific load values to establish a performance duty level for a wall cabinet structural integrity test specimen under test conditions.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What does the test data support according to the method?",{"text":117,"@type":113},"Test data helps architects, design professionals, and manufacturers judge an architectural casework assembly’s ability to maintain serviceability under actual operating conditions.",{"name":119,"@type":110,"acceptedAnswer":120},"Does the method evaluate hardware useful life or hardware serviceability?",{"text":121,"@type":113},"No. It is not intended to determine the serviceability of hardware components, and it does not determine the useful life of architectural casework in service.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663705,1793230598,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":44,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},687207022233,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Testing Methods  \nWC-2 Structural Integrity Test  \n1.0 Scope  \nThis test method determines specific load values to establish a performance duty level of the wall cabinet structural integrity specimen (henceforth referred to as “test specimen”) . These load values do not suggest service loads nor shall they be construed as suggesting normal casework usage loads.  \n2.0 Applicable Documents  \n2.1 ANSI/AWI 0641-Architectural Wood Casework (latest edition)  \n2.2 AWI Standard for Manufactured Wood Casework (latest edition)  \n2.3 AWI Standard for Specialty Casework (latest edition)  \n3.0 Significance and Use  \nTest data will provide useful information for architects, design professionals, and manufacturers in making judgments on the ability of an architectural casework assembly to maintain serviceability under actual operating conditions. This test method is not intended to determine serviceability of hardware components.  \nThis test method will not determine the useful life of architectural casework in service as a result of the data obtained during the test. It will, however, indicate the integrity of joinery and materials under test conditions.  \n4.0 Test Fixture  \n4.1 Main Testing Fixture  \nThe main testing fixture is constructed as shown in Figure 55. The test fixture is constructed of steel, wood, and other materials as indicated. The test frame must provide support for the fully loaded test specimens, elevating them no less than 229 mm [9”] above finished floor.  \n4”x4”x1/4” Wood 2x4 Angle Steel  \nArchitectural Woodwork Institute 1 Revised on November 10, 2021 3:26 PM  \n5.0 Test Specimen  \nAny specific instructions for mounting casework to the test fixture shall be included in the submittal package. Any specific hardware to be used in mounting casework to the testing fixture shall be delivered with test specimen.  \n5.1 Test Specimen Technical Drawings  \n5.1.1 Drawing Requirements  \nDrawings shall be submitted as A3 [297 mm × 420 mm] or Tabloid [11” × 17”] size documents, formatted in landscape orientation.  \nAll drawings shall be rendered in black and white.  \nText markings shall be an easily legible font in uppercase text and appropriately scaled to viewport.  \nLine weight in drawings shall be plotted in a clear and legible line weight.  \nAll measurement dimensions shall be expressed in both Metric and U.S. Customary System units of measure.  \n5.1.2 Drawing Formats  \nAll information in the submittal’s title block shall be complete and in accordance with specimen submittal drawing instructions.  \nOne set of digital test specimen drawings in PDF file format shall be attached to each test application form submitted.  \nOne set of printed drawings on A3 [297 mm × 420 mm] or Tabloid [11” × 17”] size paper shall be attached to each test specimen. Paper drawings shall be inserted into a clear plastic document protector sleeve and secured with adhesive tape to the specimen’s face.  \n5.1.3 Drawing Information Conveyance  \nDrawings shall convey joinery means and methods of intersecting casework components, as well as relevant machining dimensions.  \nDrawing shall include plan view, front elevation, side elevation, rear elevation, vertical section at each change in elevation, horizontal section at each change in elevation, auxiliary sections as required indicating faster locations, full scale details as required indicating construction method and fasteners.  \nFor clarity, full scale details shall be included as supplemental illustrations of joinery, machining, fasteners, and hardware.  \nThe location of all hardware, connectors, fasteners, and spacing shall be illustrated. Identification notes for each hardware item shall include nomenclature type, size, material, model number, and manufacturer, as applicable.  \nThe location of each type of adhesive application shall be illustrated in the drawing details. Identification notes for each adhesive item type shall include manufacturer, adhesive nomenclature type, and trade brand name, as appli","cbCaitB8YaG1Z4oE","https://ap.wps.com/l/cbCaitB8YaG1Z4oE","pdf",452004,"English","# 1.0 Scope\n# 2.0 Applicable Documents\n# 3.0 Significance and Use\n# 4.0 Test Fixture\n# 5.0 Test Specimen\n## 5.1 Test Specimen Technical Drawings\n## 5.2 Test Specimen Assembly\n# 6.0 Conditioning","[{\"question\":\"What is the purpose of the WC-2 structural integrity test method?\",\"answer\":\"It determines specific load values to establish a performance duty level for a wall cabinet structural integrity test specimen under test conditions.\"},{\"question\":\"What does the test data support according to the method?\",\"answer\":\"Test data helps architects, design professionals, and manufacturers judge an architectural casework assembly’s ability to maintain serviceability under actual operating conditions.\"},{\"question\":\"Does the method evaluate hardware useful life or hardware serviceability?\",\"answer\":\"No. It is not intended to determine the serviceability of hardware components, and it does not determine the useful life of architectural casework in service.\"}]","WC-2 Structural Integrity Test - Scope | PDF",23]