[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-650037-105":3,"detail-sidebar-cat-0-en-105":79,"doc-detail-650037-en":129},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":72,"head_meta":74,"extra_data":76,"updated_unix":78},105,"en","water-supply-drawing-index-sheet-1-of-2","Water Supply Drawing Index - Sheet 1 of 2","","Water supply drawing index sheet lists standardized water reticulation and connection details used for design coordination. The index includes drawings for typical locality planning, reticulation design plans and notes, fire hydrant location details, mains construction arrangements, and distribution or transfer layouts. It further covers connection to existing mains, property service connections to meters and conduits, potable service conduit and meter box details, large meter arrangements, and buried crossings, trench drainage, and valve or hydrant installation markers.",{"@graph":14,"@context":71},[15,34,54],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/water-supply-drawing-index-sheet-1-of-2/650037/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":48,"encodingFormat":47,"isAccessibleForFree":49,"interactionStatistic":50},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/water-supply-drawing-index-sheet-1-of-2/650037.png","ImageObject",300,407,{"name":42,"@type":43},"BAd apple","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-24",true,{"@type":51,"interactionType":52,"userInteractionCount":22},"InteractionCounter",{"@type":53},"ViewAction",{"@type":55,"mainEntity":56},"FAQPage",[57,63,67],{"name":58,"@type":59,"acceptedAnswer":60},"What does the document provide?","Question",{"text":61,"@type":62},"It provides a drawing index listing standardized water supply and reticulation drawing titles by drawing number, for coordination and reference.","Answer",{"name":64,"@type":59,"acceptedAnswer":65},"Which types of water system drawings are included in the index?",{"text":66,"@type":62},"The index covers locality planning, reticulation design and notes, mains construction and distribution/transfer arrangements, and property service connections to meters.",{"name":68,"@type":59,"acceptedAnswer":69},"Does the document describe legal or usage disclaimers?",{"text":70,"@type":62},"Yes. It states that SEQ water service providers work practices must comply with applicable occupational health and safety legislation and that the typical drawings must be adapted to the specific system or network and accompanied by detailed certified designs.","https://schema.org",{"og:url":32,"og:type":73,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":75,"canonical":32},"index,follow",{"doc_id":77,"site_id":7},650037,1792875803,{"code":4,"msg":80,"data":81},"success",[82,86,90,94,99,104,109,113,118,121,125],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":83,"show_sort_weight":84,"slug":85},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":87,"show_sort_weight":88,"slug":89},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},"Exam",70,"exam",{"id":95,"doc_module":4,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},5,"Comic",60,"comic",{"id":100,"doc_module":4,"doc_module_name":25,"category_name":101,"show_sort_weight":102,"slug":103},6,"Technology",50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":111,"slug":112},8,30,"research-report",{"id":114,"doc_module":4,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},9,"Religion & Spirituality",20,"religion-spirituality",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":119,"show_sort_weight":116,"slug":120},"World Cup","world-cup",{"id":122,"doc_module":4,"doc_module_name":25,"category_name":123,"show_sort_weight":122,"slug":124},10,"Lifestyle","lifestyle",{"id":126,"doc_module":4,"doc_module_name":25,"category_name":127,"show_sort_weight":95,"slug":128},19,"General","general",{"code":4,"msg":80,"data":130},{"doc_id":77,"user_id":131,"nickname":42,"user_avatar":132,"doc_module":4,"category_id":110,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":138,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144},19241458193282,"https://us-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","WATER SUPPLY DRAWINGS DRAWING INDEX-SHEET 1 OF 2  \n\n| DRAWING No. | DRAWING TITLE | REV No. |\n| --- | --- | --- |\n| SEQ-WAT-INDEX | WATER SUPPLY DRAWING INDEX SHEET 1 OF 2 | E |\n| SEQ-WAT-INDEX | WATER SUPPLY DRAWING INDEX SHEET 2 OF 2 | E |\n| SEQ-WAT-1100-1 | TYPICAL WATER RETICULATION LOCALITY PLAN SHEET 1 | C |\n| SEQ-WAT-1100-2 | TYPICAL WATER RETICULATION LOCALITY PLAN AND DETAILS SHEET 1 | C |\n| SEQ-WAT-1101-2 | TYPICAL WATER RETICULATION DESIGN PLAN AND DETAILS SHEET 2 | D |\n| SEQ-WAT-1101-3 | TYPICAL WATER RETICULATION DESIGN PLAN NOTES SHEET 3 | B |\n| SEQ-WAT-1101-4 | TYPICAL WATER RETICULATION FIRE HYDRANT LOCATION DETAILS SHEET 4 | A |\n| SEQ-WAT-1102-1 | TYPICAL MAINS CONSTRUCTION RETICULATION MAIN ARRANGEMENTS | C |\n| SEQ-WAT-1103-1 | TYPICAL MAINS CONSTRUCTION DISTRIBUTION AND TRANSFER MAIN ARRANGEMENTS | B |\n| SEQ-WAT-1104-1 | TYPICAL DN63 PE CUL-DE-SAC ARRANGEMENT | C |\n| SEQ-WAT-1104-2 | TYPICAL FLUSHING DETAILS FOR DN63 PE MAINS | C |\n| SEQ-WAT-1105-1 | TYPICAL CONNECTION TO EXISTING MAINS SHEET 1 OF 2 | D |\n| SEQ-WAT-1105-2 | TYPICAL CONNECTION TO EXISTING MAINS SHEET 2 OF 2 | E |\n| SEQ-WAT-1105-3 | TYPICAL CONNECTION TO EXISTING STEEL MAINS | B |\n| SEQ-WAT-1106-1 | TYPICAL PROPERTY SERVICE CONNECTION MAIN TO METER | E |\n| SEQ-WAT-1106-2 | TYPICAL PROPERTY SERVICE CONNECTION MAIN TO METER | D |\n| SEQ-WAT-1107-1 | TYPICAL PE PROPERTY SERVICES PE MAIN TO METER AND CONDUIT DETAILS | D |\n| SEQ-WAT-1107-2 | TYPICAL COPPER PROPERTY SERVICES MAIN TO METER AND CONDUIT DETAILS | D |\n| SEQ-WAT-1107-3 | TYPICAL PROPERTY SERVICES GENERAL ARRANGEMENT 20mm OR 25MM METERS | D |\n| SEQ-WAT-1108-1 | PROPERTY SERVICES POTABLE SERVICE CONNECTION CONDUIT DETAILS | C |\n| SEQ-WAT-1108-2 | PROPERTY SERVICES POTABLE SERVICE CONNECTION TYPICAL MAIN TO METER | E |\n| SEQ-WAT-1108-3 | PROPERTY SERVICES POTABLE SERVICE CONNECTION 20mm DOMESTIC SERVICE METER BOX DETAILS | E |\n| SEQ-WAT-1109-1 | PROPERTY SERVICES LONG SIDE CONNECTIONS ABOVE GROUND METER | B |\n| SEQ-WAT-1109-2 | PROPERTY SERVICES SHORT SIDE CONNECTIONS ABOVE GROUND METER | B |\n| SEQ-WAT-1109-3 | TYPICAL PROPERTY SERVICES MAIN TO METER AND CONDUIT DETAILS | A |\n| SEQ-WAT-1110-1 | PROPERTY SERVICES GENERAL ARRANGEMENT AND CONDUIT DETAILS | B |\n| SEQ-WAT-1110-2 | 20mm/25mm DOMESTIC PROPERTY WATER SERVICE INSTALLATION ASSEMBLY | B |\n| SEQ-WAT-1111-1 | LARGE METER ARRANGEMENT DESIGN PLAN NOTES | A |\n| SEQ-WAT-1111-2 | LARGE METER ARRANGEMENT DN32 AND LARGER DOMESTIC SERVICE WITH MECHANICAL METER | A |\n| SEQ-WAT-1111-3 | LARGE METER ARRANGEMENT DN32 AND LARGER DOMESTIC SERVICE FOR BASEMENT INSTALLATION WITH MECHANICAL METER | A |\n| SEQ-WAT-1111-4 | LARGE METER ARRANGEMENT DN32 AND LARGER DOMESTIC SERVICE WITH ULTRASONIC/ELECTRO MAGNETIC METER | A |\n| SEQ-WAT-1111-5 | LARGE METER ARRANGEMENT DN32 AND LARGER DOMESTIC SERVICE FOR BASEMENT INSTALLATION WITH ULTRASONIC/ELECTRO MAGNETIC METER | A |\n| SEQ-WAT-1111-6 | LARGE METER ARRANGEMENT DN32 AND LARGER DOMESTIC SERVICE WITH DN100 AND LARGER FIRE SERVICE | A |\n| SEQ-WAT-1111-7 | LARGE METER ARRANGEMENT DN32 AND LARGER DOMESTIC SERVICE WITH DN100 AND LARGER FIRE SERVICE FOR BASEMENT INSTALLATION | A |\n| SEQ-WAT-1111-8 | LARGE METER ARRANGEMENT DN50 AND LARGER FIRE SERVICE OR TOWNHOUSE STYLE C.T.S. COMBINED FIRE AND DOMESTIC SERVICE | A |\n| SEQ-WAT-1111-9 | LARGE METER ARRANGEMENT DN50 AND LARGER FIRE SERVICE FOR BASEMENT INSTALLATION | A |\n| SEQ-WAT-1111-10 | LARGE METER ARRANGEMENT DN25 AND LARGER COMMERCIAL WATER SERVICE AND DN80 AND LARGER FIRE SERVICE | A |\n| SEQ-WAT-1111-11 | LARGE METER ARRANGEMENT COMMERCIAL WATER SERVICE AND FIRE SERVICE BRACE DETAILS AND NOTES | A |\n| SEQ-WAT-1200-1 | TYPICAL SOIL CLASSIFICATION GUIDELINES AND ALLOWABLE BEARING PRESSURES FOR ANCHORS & THRUST BLOCKS | B |\n| SEQ-WAT-1200-2 | EMBEDMENT & TRENCHFILL TYPICAL ARRANGEMENT | D |\n| SEQ-WAT-1201-1 | STANDARD EMBEDMENT TYPICAL FLEXIBLE & RIGID PIPES | B |\n| SEQ-WAT-1202-1 | TYPICAL SPECIAL EMBEDMENT INADEQUATE FOUNDATIONS REQUIRING OVER EXCAVATION & REPL","cbCaivjlzs05Phgp","https://ap.wps.com/l/cbCaivjlzs05Phgp","pdf",11120099,96,"English","# Water Supply Drawing Index\n## Drawing Index (Sheet 1 of 2)\n## Drawing List by Drawing No.","[{\"question\":\"What does the document provide?\",\"answer\":\"It provides a drawing index listing standardized water supply and reticulation drawing titles by drawing number, for coordination and reference.\"},{\"question\":\"Which types of water system drawings are included in the index?\",\"answer\":\"The index covers locality planning, reticulation design and notes, mains construction and distribution/transfer arrangements, and property service connections to meters.\"},{\"question\":\"Does the document describe legal or usage disclaimers?\",\"answer\":\"Yes. It states that SEQ water service providers work practices must comply with applicable occupational health and safety legislation and that the typical drawings must be adapted to the specific system or network and accompanied by detailed certified designs.\"}]","Water Supply Drawing Index - Sheet 1 of 2 | PDF",1792815408,242]