[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-460538-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-460538-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","volumetric-absorptive-microsampling-for-lumateperone-analysis-method-validation-and-stability-evaluation","Volumetric absorptive microsampling for lumateperone analysis: method validation and stability evaluation","","Lumateperone is an atypical antipsychotic recently approved for schizophrenia, where moderate adverse effects and potential toxicity under multidrug coadministration make therapeutic drug monitoring (TDM) essential. The study develops a microsampling-based analytical methodology for lumateperone in capillary blood using volumetric absorptive microsampling (VAMS) versus plasma analysis. A streamlined VAMS protocol and an original HPLC–MS/MS method are validated for linearity, precision, extraction yield, and matrix effect, with reliability assessed against intube fluid plasma and short- to medium-term stability confirming improved analyte stability in dried microsamples.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/volumetric-absorptive-microsampling-for-lumateperone-analysis-method-validation-and-stability-evaluation/460538/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/volumetric-absorptive-microsampling-for-lumateperone-analysis-method-validation-and-stability-evaluation/460538.png","ImageObject",300,407,{"name":42,"@type":43},"Lucas Martin","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-06","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"Why is therapeutic drug monitoring important for lumateperone?","Question",{"text":63,"@type":64},"Lumateperone has moderate adverse effects, and toxicity risk increases under possible multidrug coadministration. TDM helps support personalized therapies and reduce side effects.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What sampling approach does the study use to measure lumateperone?",{"text":68,"@type":64},"The methodology uses volumetric absorptive microsampling (VAMS) on capillary blood microsamples, compared with plasma analysis.",{"name":70,"@type":61,"acceptedAnswer":71},"How is method performance and stability evaluated?",{"text":72,"@type":64},"The HPLC–MS/MS method is validated for linearity, precision, extraction yield, and matrix effect. Reliability is tested by comparison with standard intube fluid plasma, and short- and medium-term stability assays confirm improved stability in dried microsamples.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},460538,1790958601,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},8796095360427,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Analytical and Bioanalytical Chemistry (2025) 418:643–653  \n[https://doi.org/10.1007/s00216-025-06169-4](https://doi.org/10.1007/s00216-025-06169-4)  \nVolumetric absorptive microsampling for lumateperone analysis: method validation and stability evaluation  \nElisa Milandri1 · Roberta Di Lecce2 · Chiara Pia Iattoni1 · Andrea Armirotti3 · Tomaž Vovk4 · Roberto Mandrioli2 · Michele Protti1 · Laura Mercolini1  \nReceived: 31 July 2025 / Revised: 1 October 2025 / Accepted: 7 October 2025 / Published online: 19 November 2025 © The Author(s) 2025  \nAbstract  \nLumateperone is a recently approved atypical antipsychotic for the treatment of schizophrenia, with moderate adverse effects. However, the risk of toxicity, mainly due to possible multidrug coadministration, makes the therapeutic drug monitoring (TDM) approach crucial for developing personalised therapies and reducing side effects. In the TDM research field, microsampling represents an innovative and effective approach based on the collection and analysis of small sample volumes (\u003C 100 μL), exhibiting many advantages (such as enhanced analyte stability, minimally invasive procedures and simplified sample storage and transport) and improving patient adherence. For the first time, an analytical methodology based on microsampling was developed and fully validated for the analysis of lumateperone in capillary blood microsamples, by means of volumetric absorptive microsampling (VAMS) in comparison with plasma analysis, with the future perspective of supporting the TDM of psychiatric patients. A reliable and streamlined VAMS protocol was optimised, and an original HPLC–MS/MS method was developed and validated, granting satisfactory results on simulated samples in terms of linearity, precision, extraction yield and matrix effect. Method reliability was successfully tested by comparing the VAMS performance with standard intube fluid plasma, and short-and medium-term comparative stability assays confirmed the enhancement of analyte stability obtained in dried microsamples with respect to plasma samples. This is the first analytical method based on microsampling able to provide reliable data when compared to plasma analysis and promising for future TDM applications in patients treated with lumateperone, thus offering significant advantages over conventional blood/plasma sampling in terms of collection, storage and processing.  \nKeywords Lumateperone · Microsampling · Volumetric absorptive microsampling (VAMS) · Solid-phase extraction (SPE) · HPLC–MS/MS · Method development and validation  \nIntroduction  \nOver the past several years, intensive pharmacological research in psychiatric disorders has led to the development of second-generation (atypical) antipsychotics. Compared to first-generation antipsychotics (neuroleptics), these compounds show improved efficacy and tolerability, mainly due to reduced or partial affinity for dopamine D2 receptors and  \n\n| Published in the topical collection featuring Promising EarlyCareer (Bio)Analytical Researchers in 2026 with guest editors Antje J. Baeumner, Soledad Cárdenas, and Alberto Cavazzini. |\n| --- |\n| Elisa Milandri and Roberta Di Lecce contributed equally to this work. |\n\nExtended author information available on the last page of the article  \nstrong interaction with various serotonin (5-HT) receptor subtypes, which together improve quality of life in patients with schizophrenia [1, 2] .  \nAmong these agents, lumateperone (LUM, also known as ITI-007) was approved by the U.S. Food and Drug Administration (FDA) in 2019 for the treatment of schizophrenia in adults, at the oral dose of 42 mg once daily. In 2021, its indication was extended to depressive episodes associated with bipolar I or II disorder, either as monotherapy or in combination with lithium or valproate [3, 4] .  \nThe chemical structure of LUM (1-(4-fluorophenyl)−4-(3-methyl-2,3,6b,9,10,10a-hexahydro-1H-pyrido[3 ′,4 ′ :4,5] pyrrolo[1,2,3-de]quinoxalin-8(7H)-yl)−1-butanone; Fig. 1) en","cbCaiswNMRjJ3VBF","https://ap.wps.com/l/cbCaiswNMRjJ3VBF","pdf",1935632,11,"English","# Abstract\n# Keywords\n# Introduction","[{\"question\":\"Why is therapeutic drug monitoring important for lumateperone?\",\"answer\":\"Lumateperone has moderate adverse effects, and toxicity risk increases under possible multidrug coadministration. TDM helps support personalized therapies and reduce side effects.\"},{\"question\":\"What sampling approach does the study use to measure lumateperone?\",\"answer\":\"The methodology uses volumetric absorptive microsampling (VAMS) on capillary blood microsamples, compared with plasma analysis.\"},{\"question\":\"How is method performance and stability evaluated?\",\"answer\":\"The HPLC–MS/MS method is validated for linearity, precision, extraction yield, and matrix effect. Reliability is tested by comparison with standard intube fluid plasma, and short- and medium-term stability assays confirm improved stability in dried microsamples.\"}]","Volumetric absorptive microsampling for lumateperone analysis: method validation and stability evaluation | PDF",1790758730,28,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/85339b61237e811ecc65c6ee62cf6c4c.webp",983,1305,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/f8da98672e4b13d0959543e5980554eb.webp",982,1304,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/12358be3c9cd13e387066ce8ffceaf21.webp",981,1303,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3336a2772372d29f7ea4f093d8e62b36.webp",980,1301]