[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-403707-105":59,"doc-detail-403707-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","viponds-self-adhesive-prep-paint-system-interior-walls-instructional-bulletin","Viponds Self Adhesive Prep Paint System - Interior Walls - Instructional Bulletin","","Instructional Bulletin for achieving a smooth, properly dried painted wall surface for indoor wall graphics using the Viponds Self Adhesive Prep Coat paint system. Provides preparation steps for existing painted walls and new unpainted substrates, application tools and roller requirements, coat sequence and minimum two thin topcoat coats. Covers temperature and humidity limits for application, recoating and drying times, surface curing before Avery Dennison pressure-sensitive film application, plus cleaning, thinning, and approximate coverage values.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":20,"@type":76,"position":81},"https://docshare.wps.com/document/exam/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/viponds-self-adhesive-prep-paint-system-interior-walls-instructional-bulletin/403707/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/viponds-self-adhesive-prep-paint-system-interior-walls-instructional-bulletin/403707.png","ImageObject",300,407,{"name":92,"@type":93},"Himbo","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-03","2026-09-27",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What wall surface conditions are required before applying Viponds Self Adhesive Prep paints?","Question",{"text":112,"@type":113},"The surface must be dry and in sound condition, free of loose material. Any loose or flaking paint should be removed, and cracks or imperfect areas should be filled and sanded smooth and even.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the recommended temperature and humidity limits for application and drying?",{"text":117,"@type":113},"Do not apply if air or surface temperatures are below 10°C or above 30°C. For re-coating and drying, ambient conditions should be above 15°C and below 55% relative humidity (RH), with longer times under colder or more humid conditions.",{"name":119,"@type":110,"acceptedAnswer":120},"How long must Viponds Self Adhesive Prep be dried before applying Avery Dennison pressure-sensitive adhesive films?",{"text":121,"@type":113},"Dry at least 24 hours for clear and white paint, and 48 hours for coloured paint, under 15°C to 25°C ambient temperature and less than 55% RH conditions before film application.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},403707,1790822872,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":19,"category_name":20,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":24,"preview_page_count":4},687197100911,"https://ap-avatar.wpscdn.com/avatar/a000239b6f1da00475?x-image-process=image/resize,m_fixed,w_180,h_180&k=1785132997149421697","Introduction  \nA smooth, well prepared surface is critical for adhesion of pressure-sensitive films for indoor wall graphics applications. This Instructional Bulletin is designed to help you achieve a smooth and properly dried painted wall surface using Viponds Self Adhesive Prep Coat paint system.  \nThese instructions are suitable for interior application on:  \n􀁸 Existing painted walls (including acrylic or enamel painted surfaces)  \n􀁸 New unpainted walls (including plasterboard, MDF or plywood)  \nApplication Tools & Equipment  \n􀁸 High quality filler  \n􀁸 Paint scraper  \n􀁸 Medium (80 grit) and Fine (120 to 240 grit) abrasive paper  \n􀁸 4 to 6mm mohair or synthetic rollers  \n􀁸 Broad flat stirrer, Painting tray and Paint brush (for small areas only)  \n􀁸 Viponds Self-adhesive Prep Undercoat  \n􀁸 Viponds Self-adhesive Prep Topcoat Satin (clear or coloured)  \nExisting Painted Wall Surface Preparation  \nIt’s extremely important to prepare a smooth surface before applying Viponds Self Adhesive Prep paints.  \n􀁸 Ensure the surface is dry and in sound condition, free of any loose material.  \n􀁸 If the paint is loose or flaking off, use a scraper to remove before proceeding.  \n􀁸 If required fill any cracks or imperfect areas with high quality filler.  \n􀁸 Sand back any existing painted or filled surface with Medium then Fine abrasive paper to remove any texture and gloss on the surface so it is smooth and even.  \n􀁸 If unable to smooth a rough textured painted surface by sanding it is then required to be filled with high quality filler and sanded with Medium then Fine abrasive paper.  \nNew Unpainted Wall Surface Preparation  \n􀁸 Fill any holes or joins with filler and sand surface with abrasive paper until smooth and even.  \nApplication Procedure  \n􀁸 Do not apply if air or surface temperatures are below 10ºC or above 30ºC.  \n􀁸 Ensure the surface is clean and dust free before proceeding to paint.  \n􀁸 In order to produce a smooth paint finish, it is critical that only a 4 to 6 mm nap mohair or synthetic roller is used for applying both the undercoat and topcoat finish.  \n􀁸 Spot undercoat any areas which were filled with Viponds Self Adhesive Prep Undercoat, followed by one full undercoat over the entire area.  \n􀁸 Undercoat is not required for existing painted surfaces which were sanded and no filler was used.  \n􀁸 Avoid bubble formation. Lay off with a dry roller (i.e. same roller with minimal paint loading) to eliminate any bubbles.  \n􀁸 Stir paint with broad flat stirrer. Apply with roller, spray or brush (for small areas) .  \n􀁸 Inspect the surface between coats and sand any high spots and imperfections before applying the next coat.  \n􀁸 A minimum of two (2) thin coats of Viponds Self Adhesive Prep Topcoat is required.  \nRe-Coating and Drying  \n􀁸 Ambient conditions should be above 15°C and below 55% relative humidity (RH) .  \n􀁸 Under the above ambient drying conditions coatings will be touch dry in 30 minutes and can be recoated after 2 hours. These times will be longer under colder (\u003C15°C) or humid (>55% RH) conditions.  \n􀁸 Under humid conditions the use of fan assisted air flow over the paint coating system is recommended to obtain full cure.  \n􀁸 Viponds Self Adhesive Prep must be dried for at least 24 hour for clear and white paint, and 48 hours for coloured paint in 15°C to 25°C ambient temperature and less than 55% RH conditions before Avery Dennison pressure-sensitive adhesive films can be applied.  \n􀁸 *Longer drying times are required in colder (\u003C15ºC) and/or humid conditions (>55% RH) .  \nClean up, Thinning and Coverage  \n􀁸 If thinning is required use clean water only.  \n􀁸 Clean equipment with water, methylated spirits will soften and assist clean up of paints.  \n􀁸 Coverage per coat is approximately 14m²/L for Undercoat and 16m²/L for Topcoat.  \nPaint Guide  \n\\#Good condition surfaces should meet AS/NZS 2598.1. 1997, level 5 finish, see notes.  \n*Longer drying times are required in colder (\u003C15ºC) and/or humid conditions (>55% RH) .  \nSpe","cbCaifgKTFuIL0s4","https://ap.wps.com/l/cbCaifgKTFuIL0s4","pdf",174203,"English","# Introduction\n## Application Tools & Equipment\n## Existing Painted Wall Surface Preparation\n## New Unpainted Wall Surface Preparation\n## Application Procedure\n## Re-Coating and Drying\n## Clean up, Thinning and Coverage\n## Paint Guide\n## Special Notes","[{\"question\":\"What wall surface conditions are required before applying Viponds Self Adhesive Prep paints?\",\"answer\":\"The surface must be dry and in sound condition, free of loose material. Any loose or flaking paint should be removed, and cracks or imperfect areas should be filled and sanded smooth and even.\"},{\"question\":\"What are the recommended temperature and humidity limits for application and drying?\",\"answer\":\"Do not apply if air or surface temperatures are below 10°C or above 30°C. For re-coating and drying, ambient conditions should be above 15°C and below 55% relative humidity (RH), with longer times under colder or more humid conditions.\"},{\"question\":\"How long must Viponds Self Adhesive Prep be dried before applying Avery Dennison pressure-sensitive adhesive films?\",\"answer\":\"Dry at least 24 hours for clear and white paint, and 48 hours for coloured paint, under 15°C to 25°C ambient temperature and less than 55% RH conditions before film application.\"}]","Viponds Self Adhesive Prep Paint System - Interior Walls - Instructional Bulletin | PDF",1790542763]