[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-315398-105":59,"doc-detail-315398-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","venting-curb-mount-vcmes-unit-skylight-guide-specification-section-08-62-00-unit-skylights-part-1-general","Venting Curb Mount (VCM/E/S) Unit Skylight-Guide Specification - Section 08 62 00 Unit Skylights - Part 1-General","","Venting curb mount unit skylight specifications describe VELUX VCM (manual), VCE (electric), and VCS (solar) systems for commercial and residential flat, low-slope, and steep-slope roofs. The guide emphasizes energy-efficient daylighting, a maintenance-free frame, structural seals, and thermal-pane options, including LoE3–366 coating with reduced solar heat gain and UV penetration. It details testing and performance verification procedures, including load capacity, air/water tightness, durability and impact tests, U-factor and solar heat gain, burn resistance, and visual inspection, then references applicable standards and coordination requirements for curb mounting.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/venting-curb-mount-vcmes-unit-skylight-guide-specification-section-08-62-00-unit-skylights-part-1-general/315398/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/venting-curb-mount-vcmes-unit-skylight-guide-specification-section-08-62-00-unit-skylights-part-1-general/315398.png","ImageObject",300,407,{"name":92,"@type":93},"Ethan Miller","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-12","2026-09-20",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",14,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"Which VELUX venting curb mount skylight systems are covered?","Question",{"text":113,"@type":114},"The document covers VELUX manual (VCM), electric (VCE), and solar (VCS) venting curb mounted skylight systems for flat and sloped roof applications.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What roof conditions and mounting approach does the specification address?",{"text":118,"@type":114},"It specifies venting curb mount unit skylights with formed curb counterflashing for mounting on prefabricated roof curbs, suitable for flat, low-slope, and steep-slope roofing.",{"name":120,"@type":111,"acceptedAnswer":121},"What types of performance tests are used to verify compliance?",{"text":122,"@type":114},"Test procedures include load capacity, air and water tightness in test chambers and weather simulators, mechanical and impact tests, durability tests, U-factor and solar heat gain tests, burn brand resistance, and visual inspection of surface quality.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},315398,1789904668,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":130,"read_time":145,"preview_page_count":19,"preview_urls":146},687207017582,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Venting Curb Mount (VCM/E/S) Unit Skylight-Guide Specification  \nFor over 80 years, VELUX has been delivering energy efficient daylight to living spaces where people, live, work, and play. VELUX is the world leader in harnessing the benefits of the sun, providing energy efficient top lighting solutions, and recognized as one of the strongest brands in the global materials and home improvement industry.  \nVELUX manual (VCM), electric (VCE) and solar (VCS) venting curb mounted skylight systems are designed for commercial and residential flat and sloped roof applications. Daylighting provided through VELUX skylights improves the energy efficiency and visual comfort of these residential and commercial spaces. The VELUX VCM/E/S skylight system is a category leader with a maintenance free frame, structural seal, and durable thermal pane options with performance levels meeting project specifications. The thermal pane glazing options carry a 20 year warranty against seal failure, and have specially formulated LoE3 – 366™ coating. This coating, specifically designed for skylight applications, provides a high visible light transmission while reducing solar heat gain and UV penetration.  \nVELUX test facilities ensure that new products comply with regulations and market demands for technical performance. VELUX testing ensures that our products are able to withstand the most difficult climatic conditions to which VELUX products are typically exposed to in the markets where they are sold. Our test procedures include load capacity, air and water tightness in a test chamber and a weather simulator, mechanical tests, impact test results, durability tests, U-factor and solar heat gain tests, burn brand resistance and visual inspection of the surface quality.  \nContact VELUX America LLC., Greenwood, SC 29648; [www.VELUXusa.com](www.VELUXusa.com); 800-888-3589, [specifications@veluxusa.com](specifications@veluxusa.com).  \nVELUX® is a registered trademark of VKR Holding A/S This document is Copyright© 2022 by VELUX America, LLC.  \nSECTION 08 62 00 –UNIT SKYLIGHTS  \nPART 1-GENERAL  \n1.1 SECTION INCLUDES  \nA. Venting curb mount unit skylight with formed curb counterflashing for mounting on prefabricated roof curbs, for flat, low-slope and steep-slope roofing applications.  \n1.2 RELATED REQUIREMENTS  \nSpecifier: If retaining optional \"Related Sections\" article, edit to include sections applicable to Project.  \nA. Section 061053 \"Miscellaneous Rough Carpentry\" for site-built wood roof curbs for unit skylights.  \nB. Division 07 roofing section for flashing and roofing terminations at unit skylight curbs.  \nC. Section 077200 \"Roof Accessories\" for manufactured metal roof curbs for tubular unit skylights.  \nD. Section 086300 \"Metal-Framed Skylights\" for aluminum-framed sloped glazing assemblies.  \n1.3 REFERENCE STANDARDS  \nSpecifier: If retaining optional \"References\" article, edit to include standards cited in edited Section.  \nA. General: Applicable edition of references cited in this Section is current edition published on date of issue of Project specifications, unless otherwise required by building code in force.  \nB. American Architectural Manufacturers Association ([www.aama.net](www.aama.net)), Window & Door Manufacturers Association ([www.wdma.com](www.wdma.com)), Canadian Standards Association ([www.csagroup.org/us/en/services](www.csagroup.org/us/en/services))  \n1. AAMA/WDMA/CSA 101/I.S.2/A440-North American Fenestration Standard/ Specification for Windows, Doors, and Skylights (NAFS)  \n2. CSA A440S1-19 – Canadian Supplement to AAMA/WDMA/CSA 101/I.S.2/A440  \n3. AAMA 2603 – Voluntary Specification, Performance Requirements and Test Procedures for Pigmented Organic Coatings on Aluminum and Panels  \n[C. ASTM International:](C. ASTM International: www.astm.org:)[ ](C. ASTM International: www.astm.org:)[www.astm.org](C. ASTM International: www.astm.org:)[:](C. ASTM International: www.astm.org:)  \n1. ASTM B 209-Standard Specification for Aluminum an","cbCaijQdb5sm3u8S","https://ap.wps.com/l/cbCaijQdb5sm3u8S","pdf",129579,13,"English","# SECTION 08 62 00 –UNIT SKYLIGHTS\n## PART 1-GENERAL\n## 1.1 SECTION INCLUDES\n## 1.2 RELATED REQUIREMENTS\n## 1.3 REFERENCE STANDARDS\n## 1.4 COORDINATION","[{\"question\":\"Which VELUX venting curb mount skylight systems are covered?\",\"answer\":\"The document covers VELUX manual (VCM), electric (VCE), and solar (VCS) venting curb mounted skylight systems for flat and sloped roof applications.\"},{\"question\":\"What roof conditions and mounting approach does the specification address?\",\"answer\":\"It specifies venting curb mount unit skylights with formed curb counterflashing for mounting on prefabricated roof curbs, suitable for flat, low-slope, and steep-slope roofing.\"},{\"question\":\"What types of performance tests are used to verify compliance?\",\"answer\":\"Test procedures include load capacity, air and water tightness in test chambers and weather simulators, mechanical and impact tests, durability tests, U-factor and solar heat gain tests, burn brand resistance, and visual inspection of surface quality.\"}]","Venting Curb Mount (VCM/E/S) Unit Skylight-Guide Specification - Section 08 62 00 Unit Skylights - Part 1-General | PDF",33,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/e4b562f0576e992a1da49f1d422c36bc.webp",983,1272,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/91efc31cbb937ece6fc45e5cc6436b7e.webp",982,1270,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/9f344e201f10d23b02222838c0d6083e.webp",981,1269,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/3465c436d80df66afc7670219488b43c.webp",980,1268]