[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-646640-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-646640-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","vec-51-1061-1067-programming-guide-door-open-control-sequence-programming-checklist-error-codes","VEC 5.1-1061-1067 Programming Guide - Door Open Control Sequence - Programming Checklist - Error Codes","","This programming guide describes the door-open control sequence for a Vendo vendor control, including diagnostic error handling, sales information display flows, and alternate test vend behavior. It provides a step-by-step programming checklist covering Space to Sales (SSS), option settings, price ranges, timer control, and required delays when exiting service modes. Detailed error codes (ER-1 through ER-9 and MDB-related variants) specify the actions to identify faults, clear errors, and validate repairs through test vend procedures.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/vec-51-1061-1067-programming-guide-door-open-control-sequence-programming-checklist-error-codes/646640/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/vec-51-1061-1067-programming-guide-door-open-control-sequence-programming-checklist-error-codes/646640.png","ImageObject",300,407,{"name":42,"@type":43},"\tCallum ","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-29","2026-10-23",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What is the required wait time after exiting service modes before the vendor accepts coins or bills?","Question",{"text":62,"@type":63},"After exiting “Service Modes” (for example, actuating the door switch), wait 30 seconds before the vendor will accept coins or bills.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"How should the Space to Sales (SSS) assignments be confirmed?",{"text":67,"@type":63},"Confirm each selection has the correct column(s) assigned and that each column is assigned to at least one selection. Use the Quick Set (SSSS) mode as a starting point and press the last selection button (Selection 9 or 10 depending on model).",{"name":69,"@type":60,"acceptedAnswer":70},"What actions are recommended when an error code like ER-3, ER-5, or ER-9 is displayed?",{"text":71,"@type":63},"ER-3: remove the error code and close the door, then press the mode switch and hold any selection switch for 2 seconds. ER-5: identify the specific CCO/TUBE/ICB cause, repair it, then press any selection switch for 2 seconds while ER-5 is displayed. ER-9: identify the bill-related cause, repair it, then press any selection switch for 2 seconds while ER-9 is displayed.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},646640,1793073047,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145},137451211410,"https://ap-avatar.wpscdn.com/avatar/2000bb0a9246f588df?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786362646172706240","THE VENDO COMPANY  \n7209 North Ingram Ave Fresno, CA 93650 Phone (800) 344-7216-Fax (800) 541-5684  \n\n| \u003Cbr>VEC 5.1-1061-1067 Programming Guide |\n| --- |\n| \u003Cbr>DOOR OPEN CONTROL SEQUENCE |\n| 1. Diagnostic Error Codes\u003Cbr>2. Sales Information\u003Cbr>3. Alternate Test Vend\u003Cbr>4. Control Operation & Programming |\n\n\n| \u003Cbr>PROGRAMMING CHECKLIST |\n| --- |\n| NOTICE: Do not enter the programming modes ofthis control without\u003Cbr>authorization and proper training.\u003Cbr>The leading cause of vendor malfunction is a control board that is not properly programmed. When installing a new board or when trying to troubleshoot a vendor that is not operating as expected, follow these steps in the order listed. |\n| 1. Space to Sales (SSS) . Confirm each selection has the correct column(s)\u003Cbr>assigned. Confirm each column is assigned to at least one selection. As a starting point, assign columns to selections using the Quick Set (SSSS) Mode and pressing the last selection button (Selection 9 or 10 depending on model) . |\n| 2. Options (OPTS) & (OPT 2) . Check the settings for each of the different options. As a starting point, set all options to factory settings. |\n| 3. Price Setting (COST) . Set each selection to desired price from .00 (Free Vend) to $99.95 |\n| 4. Timer Control (TCTL) . If an optional timing device or key switch is installed, check that the selections are set as desired. (Be sure the optional timing device is operating properly.) |\n| 5. When exiting “Service Modes”(i.e. actuating the door switch) you must wait 30 seconds before the vendor will accept coins or bills. |\n\nFor detailed instructions, refer to the Service and Operation Manual or call the Technical Services Department of The Vendo Company at 800-344-7216 or 559-439-1770.  \n\n| \u003Cbr>ERROR CODES |  |  |\n| --- | --- | --- |\n| ERROR CODE | ACTION | TO REMOVE ERROR CODE |\n| “NONE”No Reported Errors | No action needed | No Error Code to remove. Control board will automatically go to total historical vends. |\n| “ER-1”\u003Cbr>Jammed Column | Press Mode Switch 1 time to identify jammed column(s) | Remove cause of motor jam and test vend all columns vended by that motor. |\n| “ER-3”\u003Cbr>Door Left Open 1 Hour | Remove the error code and close the door | While ER-3 is displayed, press the mode switch then press and hold any selection switch for 2 seconds |\n| “ER-4”\u003Cbr>Stuck Selection Switch | Press Mode Switch 1 time to identify stuck switch(es) | Automatically cleared when stuck switch is repaired. |\n| “ER-5”\u003Cbr>MDB Changer Error (Valid only with MDB Interface) | Press Mode Switch 1 time to identify:“CCO”= Coin Changer\u003Cbr>Communication\u003Cbr>“TUBE” = Coin Tubes Low“ICB”= Inlet Chute Blocked | After repair, press any selection switch for 2 seconds while ER-5 is displayed. |\n| “ER-6”\u003Cbr>MDB Coin Changer Error (Valid only with MDB Interface) | Press Mode Switch 1 time to identify:“ESC” = Excessive Escrow Attempts“JA” = Coin Jam in Changer“LO” = Low Coin Acceptance | After repair, press any selection switch for 2 seconds while ER-6 is displayed. |\n| “ER-7”\u003Cbr>MDB Card Reader Error (Valid only with MDB Interface) | Press Mode Switch 1 time to identify:“CrOx” = Card Reader Error“Cr1x” = Invalid Card\u003Cbr>“Cr2x” = Tamper Error\u003Cbr>“Cr3x” = Manufactures Defined Error“Cr4x” = Communication Error“Cr5x’ = Reader Requires Service“Cr6x” = Unassigned\u003Cbr>“Cr7x” = Manufactures Defined Error“Cr8x” = Reader Failure\u003Cbr>“Cr9x” = Communication Error-Inop Reader\u003Cbr>“CrAx”= Card Jammed\u003Cbr>“CrBx” = Manufactures Defined Error | After repair, press any selection switch for 2 seconds while ER-7 is displayed. |\n\n\n| “ER-8”\u003Cbr>STS Assignment Error\u003Cbr>(SSS) | Press Mode Switch 1 time to identify:“SS_” = Unassigned Switch(es)“UA_” = Unassigned Column (5.1 Only)“DA_” = Doubly Assigned Column (5.1 Only) | Automatically cleared when assignment error is corrected through SSS program mode. |\n| --- | --- | --- |\n| “ER-9”\u003Cbr>MDB Bill Validator Error (Valid only with MDB Interface) | Press Mode Switch 1 time to identify:“BOPN” = Bill Box Open\u003Cb","cbCaimjjSjsHWszD","https://ap.wps.com/l/cbCaimjjSjsHWszD","pdf",172113,13,"English","# DOOR OPEN CONTROL SEQUENCE\n## Diagnostic Error Codes\n## Sales Information\n## Alternate Test Vend\n## Control Operation & Programming\n# PROGRAMMING CHECKLIST\n## Space to Sales (SSS)\n## Options (OPTS) & (OPT 2)\n## Price Setting (COST)\n## Timer Control (TCTL)\n## Exiting Service Modes Delay\n# ERROR CODES\n## NONE\n## ER-1 to ER-9 (including MDB interface errors)\n# SALES INFORMATION\n## DESIRED DISPLAY and NEXT CONTROL ACTION\n# ALTERNATE TEST VEND\n## Display behavior after inactivity","[{\"question\":\"What is the required wait time after exiting service modes before the vendor accepts coins or bills?\",\"answer\":\"After exiting “Service Modes” (for example, actuating the door switch), wait 30 seconds before the vendor will accept coins or bills.\"},{\"question\":\"How should the Space to Sales (SSS) assignments be confirmed?\",\"answer\":\"Confirm each selection has the correct column(s) assigned and that each column is assigned to at least one selection. Use the Quick Set (SSSS) mode as a starting point and press the last selection button (Selection 9 or 10 depending on model).\"},{\"question\":\"What actions are recommended when an error code like ER-3, ER-5, or ER-9 is displayed?\",\"answer\":\"ER-3: remove the error code and close the door, then press the mode switch and hold any selection switch for 2 seconds. ER-5: identify the specific CCO/TUBE/ICB cause, repair it, then press any selection switch for 2 seconds while ER-5 is displayed. ER-9: identify the bill-related cause, repair it, then press any selection switch for 2 seconds while ER-9 is displayed.\"}]","VEC 5.1-1061-1067 Programming Guide - Door Open Control Sequence - Programming Checklist - Error Codes | PDF",1792765162,33]