[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663467-105":59,"doc-detail-663467-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","ve-3-drawings-specs-hydraulic-unit-and-elevator-installation-requirements","VE-3 Drawings Specs - Hydraulic Unit and Elevator Installation Requirements","","Elevator equipment drawings specs for a vehicle elevator system, covering anchor reinforcement heights, access levels, pit and lower access floor dimensions, and hydraulic unit requirements. Specifies 220 Vac 3-phase power with neutral and earth grounding, protection via thermomagnetic breaker, cable wire gauges by distance, and straight duct/tubing routing for the hydraulic system. Includes hydraulic oil type ISO 68, cabinet/duct recommendations, installation readiness conditions for the pit and power supply, plus core elevator safety mechanisms and safe operating instructions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ve-3-drawings-specs-hydraulic-unit-and-elevator-installation-requirements/663467/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ve-3-drawings-specs-hydraulic-unit-and-elevator-installation-requirements/663467.png","ImageObject",300,407,{"name":92,"@type":93},"Malam Tenang","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What power supply and protection requirements are specified for the hydraulic unit?","Question",{"text":112,"@type":113},"The document specifies a 3-phase 220 Vac power supply with neutral and earth ground, using a thermomagnetic breaker of protection rated at 40 Amp exclusively for the elevator.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the document guide wire gauge selection based on cable distance?",{"text":117,"@type":113},"It states 8 AWG for distances up to 10.00 m, 6 AWG for distances up to 15.00 m, and for distances greater than 15.00 m to use current calculation to avoid tension fall, using straight pipe Ø3\" for channeling the hydraulic system.",{"name":119,"@type":110,"acceptedAnswer":120},"What installation readiness conditions and safety rules are required before operating the elevator?",{"text":121,"@type":113},"Installation requires optimal pit conditions (no waterlogging and work area free of objects) and adequate 220V energy to connect equipment with 60 Amp consumption capacity. Safety rules include not taking hands/feet or objects out during operation, not operating with hydraulic fluid leaks, verifying doors are tightly closed, respecting weight capacity, and never using the elevator in case of fire.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663467,1793228322,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":39},962093532863,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","|  EQUIPMENT DESCRIPTION |  |  |  |  |  |  | Element in building for Anchor Team\u003Cbr>ACCESS\u003Cbr>3rd Level  +32' 9 11/₁₆\" (10m)\u003Cbr>\u003Cbr>ACCESS\u003Cbr>2nd Level +m\u003Cbr>\u003Cbr>Element in building for Anchor Team\u003Cbr>LOWER ACCESS FLOOR\u003Cbr>\u003Cbr>\u003Cbr> +0.00m \u003Cbr>PIT\u003Cbr>\u003Cbr>\u003Cbr> -1' 11 5/₈\" (0.60m) | Reinforcement +38' 8 ⁹/₁₆\" (11 . 8m)\u003Cbr>Reinforcement +32' 9 ¹¹/₁₆\" (10m)\u003Cbr>Reinforcement +26' 2 ¹⁵/₁₆\" (8m)\u003Cbr>Reinforcement +20' 11 ¹⁵/₁₆\" (6 .4m)\u003Cbr>Reinforcement +15' 9 \" (4 . 8m)\u003Cbr>Reinforcement +10' 6\" (3 . 2m)\u003Cbr>Reinforcement +5' 3\" (1 . 6m)\u003Cbr>LOW FLOOR\u003Cbr>\u003Cbr>\u003Cbr>PIT\u003Cbr>-1' 11 ⁵/₈\" (-0 . 6m) |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| \u003Cbr>|  |  |  |  |  |  |  |  |\n| |  |  |  |  |  |  |  |  |\n| ACCE\u003Cbr>SS | | 19' 8 ¹/₄\" (6 . 00m) 19' ³/₈\" (5 . 8m) | D\u003Cbr>D´ |  |  ANCHOR REINFORCE- HEIGHTS\u003Cbr>CAR LIFT\u003Cbr>SIDE |  |  |  |\n|  | \u003Cbr>|  |  | \u003Cbr>8' 6 3/8\" (2 . 6m) 10' 9 1 5/16\" (3 .3m) |  |  |  |  |\n|  | |  |  |  |  |  |  |  |\n\n\n|  | |\n| --- | --- |\n| 1. THIS DRAWING IS THE PROPERTY OF PARKMATICAND IT MAY NOT BE REPRODUCED IN WHOLE OR PART OR USED FOR THE MANUFACTURE OF ANY ARTICLE WITHOUT PRIOR WRITTEN CONSENT.\u003Cbr>2. WORK TO FIGURED DIMENSIONS ONLY.\u003Cbr>3. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECT'S AND ENGINEER'S DRAWINGS AND SPECIFICATIONS. |  |\n| |  |\n|  |  |\n\n\n| 3 |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| 2 |  |  |  |  |\n| 1 |  |  |  |  |\n| | | | | |\n\n\n| PARKMATIC |  |\n| --- | --- |\n| | NEW YORK OFFICE, USA\u003Cbr>1129 Northern Blvd, \\#452 Manhasset, NY 11030\u003Cbr>P: 1-800-422-5438\u003Cbr>W: [www.parkmatic.com](www.parkmatic.com) |\n\n|  VEHICLE ELEVATOR |  |  |  |\n| --- | --- | --- | --- |\n| N/A | \u003Cbr>05/08/2020 | | MW |\n| SK/01 |  | \u003Cbr>2 OF 3 |  |\n\n|  HYDRAULIC UNIT\u003Cbr>For the operation of the elevator, a hydraulic unit is necessary, which does notice contemplated within the elevator clearing, the customer is given the option to decide the location of the unit. Niche is required to house the unit hydraulics and electrical control having access for maintenance.\u003Cbr>The hydraulic unit and electrical control must be installed and located in a place free of dust, liquids and inclement weather, preventing contamination of the oil and equipment warranty is forfeited.\u003Cbr>The tubing path must not be greater than 5.00 linear meters 3-phase 220 Vac power supply, with neutral and earth ground, with a thermomagnetic break of protection 40 Amp, exclusive for the elevator.\u003Cbr>• Wire gauge 8 AWG for distances up to 10.00m.\u003Cbr>• 6 AWG gauge for distances up to 15.00m.\u003Cbr>• For distances greater than 15.00m consider the current calculation to avoid tension fall completely straight pipe of Ø 3¨ for channeling the hydraulic system.\u003Cbr>For security, it should not be manipulated by unauthorized personnel. By ignoring the indications already dictated and the equipment has a fault, Parkmatic will not be responsible for these, in addition to the guarantee year not would have coverage for these damages. |  | \u003Cbr>Louver Door For Equipment Protection\u003Cbr>Totally Straight Duct Ø3” for Channeling Hydraulic System.\u003Cbr>Recommended to Place a Cabinet to Protect the Weather Engine\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>W\u003Cbr>\u003Cbr>X\u003Cbr>\u003Cbr>1\u003Cbr>\u003Cbr>2\u003Cbr>6' 6 3/4\" (2m) |  |  3” Duct\u003Cbr>\u003Cbr>|  | | Wiring Pipe Electric |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  | \u003Cbr>|  |  |  |\n|  |  |  |  | 3” Duct\u003Cbr>Wiring Pipe Electric \u003Cbr>\u003Cbr>Tubing |  |  |  |\n| HYDRAULIC UNIT DESCRIPTION HYDRAULIC UNIT 10HP FEEDING 220 VCA NUMBER OF PHASES 3 CONSUMPTION AMPS 27 CONSUMPTION WATTS 7.4 KW TYPE OF OIL ISO 68\u003Cbr>| CABINET FOR 10 HP\u003Cbr>Totally Straight Duct Ø3\" for Channeling Hydraulic System.\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>1\u003Cbr>\u003Cbr>2\u003Cbr>\u003Cbr>W\u003Cbr>\u003Cbr>X\u003Cbr>2' 1 9/16\"( 0. 65m)\u003Cbr>|  | \u003Cbr>\u003Cbr>Parkmatic\u003Cbr>4\"X4\" Electrical Register for Wiring Connection\u003Cbr>in Motor Area\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>Distance \"B\" will be covered if possible, with ducts made with pipe and the exit in the pit will be recommended to locate it from the side where they will meet the columns and the rest of","cbCaijRwETu2V5xR","https://ap.wps.com/l/cbCaijRwETu2V5xR","pdf",5932624,"English","# Hydraulic unit and electrical control\n## Power supply, wiring gauges, and protection\n## Tubing/duct routing and equipment protection\n# Hydraulic unit specifications\n## Oil type and hydraulic capacity\n## Cabinet and electrical registers\n# Installation requirements\n## Pit conditions and transport access\n## Power capacity and scheduling\n# Elevator safety\n## Safe operating rules and prohibitions","[{\"question\":\"What power supply and protection requirements are specified for the hydraulic unit?\",\"answer\":\"The document specifies a 3-phase 220 Vac power supply with neutral and earth ground, using a thermomagnetic breaker of protection rated at 40 Amp exclusively for the elevator.\"},{\"question\":\"How does the document guide wire gauge selection based on cable distance?\",\"answer\":\"It states 8 AWG for distances up to 10.00 m, 6 AWG for distances up to 15.00 m, and for distances greater than 15.00 m to use current calculation to avoid tension fall, using straight pipe Ø3\\\" for channeling the hydraulic system.\"},{\"question\":\"What installation readiness conditions and safety rules are required before operating the elevator?\",\"answer\":\"Installation requires optimal pit conditions (no waterlogging and work area free of objects) and adequate 220V energy to connect equipment with 60 Amp consumption capacity. Safety rules include not taking hands/feet or objects out during operation, not operating with hydraulic fluid leaks, verifying doors are tightly closed, respecting weight capacity, and never using the elevator in case of fire.\"}]","VE-3 Drawings Specs - Hydraulic Unit and Elevator Installation Requirements | PDF"]