[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-641193-105":59,"doc-detail-641193-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","vandal-resistant-laminar-outlet-with-antimicrobial-by-agion-15-gpm-5-7-lmin-installation-and-setup-instructions","Vandal Resistant Laminar Outlet with Antimicrobial by Agion® 1.5 GPM (5 .7 L/min) - Installation and Setup Instructions","","Installation and setup instructions for a vandal-resistant laminar outlet system with antimicrobial protection by Agion®. The sheet lists compatible outlet and accessory components, including aerators, flow-control parts, deck plates, hoses, solenoid valve fittings, and power options (battery version or 24 VAC converter/hardwire). It specifies disinfection-cycle and system-pressure guidance, plus step-by-step faucet mounting, battery box installation, flushing, water-supply connections, and power-up procedures with safety warnings and torque/sealant notes.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/vandal-resistant-laminar-outlet-with-antimicrobial-by-agion-15-gpm-5-7-lmin-installation-and-setup-instructions/641193/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/vandal-resistant-laminar-outlet-with-antimicrobial-by-agion-15-gpm-5-7-lmin-installation-and-setup-instructions/641193.png","ImageObject",300,407,{"name":92,"@type":93},"Tirek","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-27","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the recommended practice for mounting the faucet on the deck surface?","Question",{"text":112,"@type":113},"Mount the faucet using the provided nuts and washers, and install the single-hole deck gasket (060564A) between the turret base and mounting surface. Keep the gasket flat and center the turret; avoid overtightening or repositioning after installation to prevent gasket damage.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How should the system be flushed before connecting the solenoid inlet?",{"text":117,"@type":113},"Assemble the specified components (Fig. 3) and run water for 1 minute, then shut off the water supply. Attach the aerator and do not connect the supply to the solenoid inlet until the line is flushed directly out through the spout.",{"name":119,"@type":110,"acceptedAnswer":120},"What power options does the sheet provide and what are key cautions?",{"text":121,"@type":113},"Use either the battery version (install four Alkaline C batteries in the battery holder) or a hardwire version using a CSA/UL-approved Class 2 transformer or equivalent (do not install the transformer inside the control box). Do not use a 9V battery, and connect wiring carefully without damaging driver-board components.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},641193,1792984099,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":46},5909896572756,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","208356 208356 208356 208356  \n060638A  \nVandal Resistant Laminar Outlet with Antimicrobial by Agion® 1.5 GPM (5 .7 L/min)  \n060640A  \nVandal Resistant Flow Control Aerator and Wrench  \n1.5 GPM (5 .7 L/min)  \n061203A  \nVandal Resistant Laminar  \nOutlet with Wrench 0.5 GPM (1 .9 L/min)  \n061176A  \nVandal Resistant Laminar Outlet with Wrench  \n1.0 GPM (3 .8 L/min)  \n061104A  \nVandal Resistant Flow Control Non-Aerating Spray Outlet with Wrench  \n0.35 USGPM (1 .3 L/min)  \nRP31704-Optional  \nVandal Resistant Spray Outlet with Wrench 0.5 GPM (1 .9 L/min)  \n060566A-Optional  \nVandal Resistant Spray Outlet with Wrench  \n1.0 GPM (3 .8 L/min)  \n060765A  \nWrench  \n060564A  \nSingle Hole Deck Gasket (6/pkg)  \nAccessories  \n060683A  \n24 VAC/6 .4 VDC Converter  \n061256A  \n36” Cable Extension  \n| 590T        |\n| --- |\n| Write purchase model number here for future reference |\n\nNOTE: Control Box \\#0 and \\#1 are designed for routine 171° F (77°C) disinfection cycles up to 30 minutes.  \nControl Box \\#8 is not recommended for high temperature disinfection cycles as the thermostatic mixing valve limits the higher temperature flow output.  \nNOTE: For optimum performance of this product, we recommend a system pressure between 20 and 80 PSI static. This product will operate up to a maximum of 125 PSI static per ANSI and CSA requirements. However, we do not recommend pressure above 80 PSI. Thermal expansion or leaking pressure reducing valves may require the use of expansion tanks or relief valves to ensure your system never exceeds its maximum intended pressure setting.  \nRP6087  \n Nut and Washer  \nRP30523  \nBraided Hose  \n  063127A  \nSolenoid Valve with 3/8”  \nCompression  \nConnectors  \n\n| OPTION LIST |\n| --- |\n| \u003Cbr>060681A\u003Cbr>Battery Holder |\n| TRANSFORMERS 060704A\u003Cbr>Transformer 110 to 24 VAC 20VA up to 5 Electronic Valves\u003Cbr>060771A\u003Cbr>Transformer 110 to 24 VAC 40VA up to 10 Electronic Valves\u003Cbr>060772A\u003Cbr>Transformer 110 to 24 VAC 100VA up to 25 Electronic Valves |\n| DECK PLATES\u003Cbr>060546A\u003Cbr>4” Deck Plate & Hold-Down Pkg\u003Cbr>060547A\u003Cbr>8” Deck Plate & Hold-Down Pkg |\n\n208356 208356 208356 208356  \n060905A   \nCover Gasket  \n060906A  \nSurface Mount Housing  \n061252A ~~ ~~  \nDual Driver Board Masco H 2Optics & Proximity  \n063128A  \nBattery Box Assembly less driver board and battery holder  \n063127A  \nSolenoid Valve with 3/8”Compression Connectors  \n060908A  \nSolenoid Holder  \n 060909A  \nScreen Assembly  \n063131A  \n3/8” Comp Connect Nut and Ferrile  \n063131A  \n3/8” x 3/8”Compression  \nConnector, Nut and Ferrule  \nRP6092  \n060546A  \n4” Deck Plate and Hold-Down Package  \n060547A  \n8” Deck Plate and Hold-Down Package  \nNut and Washer  \nFig. 1  \nPLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, [etc. as](etc. as)[ ](etc. as)[items relating to ongoing maintenance suggestions and procedures are included.](items relating to ongoing maintenance suggestions and procedures are included.)  \n[ww w . spec select . co m](ww w . spec select . co m)  \nPage 1 208356 Rev. C  \nInstallation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.  \nINSTALLATION AND SET UP INSTRUCTIONS  \nFOR SURFACE MOUNT HOUSING: CONTROL BOX \\#0 STEP 1. FAUCET INSTALLATION  \n\n| Connect 20” braided hose to spout inlet. Clean deck/sink surface where faucet will be mounted. Mount faucet to sink using nut(s) and washer(s) provided. Installation of the single hole deck gasket (060564A) between the turret base and mounting surface is the recommended assembly practice. Ensure that gasket is sitting flat on the deck and the turret is centered on the gasket. Use the same procedure for installation of optional 4”or 8” deck plate package (060546A or 060547A) . Mount the faucet to the sink using nut(s) and washer(s) provided. Do not overtighten the nut (RP6087) or reposition the turret once installed, otherwise damage to the gasket may result. Cutting or trimming of the gasket is not recommended. NOTE: If the gasket is trimmed ","cbCais7qyCqdETSv","https://ap.wps.com/l/cbCais7qyCqdETSv","pdf",5323231,"English","# Installation and Setup Instructions for Surface Mount Housing: Control Box #0\n## Step 1. Faucet Installation\n## Step 2. Battery Box Installation\n## Step 3. Flush System\n## Step 4. Connect Water Supply\n## Step 5. Power Up","[{\"question\":\"What is the recommended practice for mounting the faucet on the deck surface?\",\"answer\":\"Mount the faucet using the provided nuts and washers, and install the single-hole deck gasket (060564A) between the turret base and mounting surface. Keep the gasket flat and center the turret; avoid overtightening or repositioning after installation to prevent gasket damage.\"},{\"question\":\"How should the system be flushed before connecting the solenoid inlet?\",\"answer\":\"Assemble the specified components (Fig. 3) and run water for 1 minute, then shut off the water supply. Attach the aerator and do not connect the supply to the solenoid inlet until the line is flushed directly out through the spout.\"},{\"question\":\"What power options does the sheet provide and what are key cautions?\",\"answer\":\"Use either the battery version (install four Alkaline C batteries in the battery holder) or a hardwire version using a CSA/UL-approved Class 2 transformer or equivalent (do not install the transformer inside the control box). Do not use a 9V battery, and connect wiring carefully without damaging driver-board components.\"}]","Vandal Resistant Laminar Outlet with Antimicrobial by Agion® 1.5 GPM (5 .7 L/min) - Installation and Setup Instructions | PDF",1792713171]