[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-641385-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-641385-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","user-instructions-pearl-premium-operation-manual-safety-and-maintenance","Upute-za-korisnika Pearl premium - Operation manual - Safety and maintenance","","Operation manual for a split type room air conditioner, covering key safety warnings, refrigeration and wiring requirements, and usage precautions. It specifies that the appliance is filled with R32, prohibits using other refrigerants, and details installation conditions such as ventilation, cable types, earthing connection, and disconnection devices. It also includes warnings for a built-in UV-C lamp, maintenance steps, protective barriers, power isolation before service, and guidance on replacement by qualified personnel.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/user-instructions-pearl-premium-operation-manual-safety-and-maintenance/641385/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/user-instructions-pearl-premium-operation-manual-safety-and-maintenance/641385.png","ImageObject",300,407,{"name":42,"@type":43},"The UK Girl","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-12","2026-10-23",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",12,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What refrigerant is this air conditioner filled with, and what should be avoided during service or installation?","Question",{"text":63,"@type":64},"The appliance is filled with R32. Do not use any refrigerant other than the one indicated on the outdoor unit (R32) when installing, moving, or repairing, as it may cause trouble, damage, and personal injury.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What are the main requirements for installation wiring and earthing?",{"text":68,"@type":64},"Installation wiring must follow local wiring standards, using the specified connecting wire type (H07RN-F). Earthing must be connected first, and an explosion-proof leakage breaker should be installed with safe disconnection incorporated in the wiring.",{"name":70,"@type":61,"acceptedAnswer":71},"How should UV-C lamp related maintenance and safety be handled?",{"text":72,"@type":64},"Read maintenance instructions before opening. Cut off power before approaching during air filter taking and UV-C lamp service, do not remove UV-C barriers, and do not operate UV-C lamps outside the appliance; replace damaged lamps only with qualified personnel.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},641385,1792719988,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,110,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":108,"slug":109},7,40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":112,"show_sort_weight":113,"slug":114},8,"Research & Report",30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":107,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":140,"language":141,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":12,"update_tm":145,"read_time":146,"preview_page_count":4},2199028711991,"https://us-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","OPERATION MANUAL  \nSPLIT TYPE ROOM AIR CONDITIONER  \n• Please read this operation manual before using the air conditioner. Keep this operation manual for future reference This appliance is filled with R32 .  \nEnglish  \nItaliano  \nDanish  \nNorsk  \nSvenska  \nMagyar  \nEspañol  \nFrançais  \nDeutsch  \nPortuguês  \nPolski  \nΕλληνικά  \nHrvatski  \nбългарски  \nNederlands  \nČesky  \nModel List：  \nAS25PCHHRA-NR  \nAS35PCHHRA-NR  \nAS50PDHHRA-NR  \nAS25PBPHRA-PRE  \nAS35PBPHRA-PRE  \nAS50PDPHRA-PRE  \nAS71PEPHRA-PRE  \nAS25PBAHRA-PRO  \nAS35PBAHRA-PRO  \nAS50PDAHRA-PRO  \nAS71PDAHRA-PRO  \nAS25RBAHRA-PL  \nAS35RBAHRA-PL  \nAS50RCBHRA-PL  \nAS68RDAHRA-PL  \nAS50RDAHRA-PL  \nAS25RBAHRA-3  \nAS35RBAHRA-3  \nAS50RCBHRA-3  \nAS68RDAHRA-3  \nAS35RBAHRA-4  \nAS50RCBHRA-4  \nAS68RDAHRA-4  \nAS25PBPHRA-BH  \nAS35PBPHRA-BH  \nAS50PDPHRA-BH  \nAS25PBPHRA-S  \nAS35PBPHRA-S  \nAS50PDPHRA-S  \nAS25RBAHRA-5  \nAS35RBAHRA-5  \nAS50RDAHRA-5  \nAS68RDAHRA-5  \nNote: All the illustrations in this manual are for explanation purpose only. Your air conditioner may be slightly different. The actual shape shall prevail. They are subject to change without notice for future improuement.  \nContents  \nWARNING .....................................................................................................................................1  \nParts and Functions.......................................................................................................................3  \nOperation .......................................................................................................................................4  \nIndoor Unit Installation .................................................................................................................10  \nMaintenance ................................................................................................................................13  \nTrouble shooting ..........................................................................................................................13  \nCautions ......................................................................................................................................14  \nEN  \nEN  \n\n| | Read the precautions in this manual carefully before operating the unit. | | This appliance is filled with R32 . |\n| --- | --- | --- | --- |\n\nKeep this manual where the user can easily find it.  \nWARNING  \n■ Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.  \n■ The unit must be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater)  \n■ Do not pierce or burn.  \n■ Be aware that refrigerants may not contain an odor.  \n■ The appliance must be installed, operated and stored in a room with a floor area larger than 3 m² .  \n■ If the supply cord is damaged, it must be replaced by a qualified person in order to avoid a hazard.  \n■ This appliance can be used by children and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.  \n■ The wiring method should be in line with the local wiring standard.  \n■ All the cables shall have the European authentication certificate. During installation, when the connecting cables are being installed, it must be assured that the Earthing wire is the first one to be connected. The explosion-proof breaker of the air conditioner should be all-pole switch. Distance between its two contacts should not be no less than 3mm. Such means for disconnection must be incorporated in the wiring.  \n■ Make sure installation is done according to local wiring regulation by professional persons.  \n■ Make sure ground connection is correct and reliable. A leakage explosion-proof breaker must be installed.  \n■ Do ","cbCaiqGsM9D57lht","https://ap.wps.com/l/cbCaiqGsM9D57lht","pdf",42054616,260,"English","# WARNING\n## Safety and operation precautions\n## UV-C lamp maintenance warnings\n# Contents\n## Parts and Functions\n## Operation\n## Indoor Unit Installation\n## Maintenance\n## Trouble shooting\n## Cautions","[{\"question\":\"What refrigerant is this air conditioner filled with, and what should be avoided during service or installation?\",\"answer\":\"The appliance is filled with R32. Do not use any refrigerant other than the one indicated on the outdoor unit (R32) when installing, moving, or repairing, as it may cause trouble, damage, and personal injury.\"},{\"question\":\"What are the main requirements for installation wiring and earthing?\",\"answer\":\"Installation wiring must follow local wiring standards, using the specified connecting wire type (H07RN-F). Earthing must be connected first, and an explosion-proof leakage breaker should be installed with safe disconnection incorporated in the wiring.\"},{\"question\":\"How should UV-C lamp related maintenance and safety be handled?\",\"answer\":\"Read maintenance instructions before opening. Cut off power before approaching during air filter taking and UV-C lamp service, do not remove UV-C barriers, and do not operate UV-C lamps outside the appliance; replace damaged lamps only with qualified personnel.\"}]","Upute-za-korisnika Pearl premium - Operation manual - Safety and maintenance | PDF",1792713827,655]