[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646541-105":59,"doc-detail-646541-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","use-and-care-guide-80-gallon-stationary-air-compressor-safety-information","USE AND CARE GUIDE - 80-GALLON STATIONARY AIR COMPRESSOR - Safety Information","","Use and care guide for an 80-gallon stationary air compressor, including safety information, warnings, cautions, and operational precautions. Covers breathable air limitations, warranty disclaimer for misuse, and strict tank repair prohibition. Provides guidance to prevent equipment problems through correct handling, safe operation rules, and attention to risks from moisture, rust, and fast-moving air. Includes personal and electrical safety instructions such as grounding and qualified wiring requirements.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/use-and-care-guide-80-gallon-stationary-air-compressor-safety-information/646541/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/use-and-care-guide-80-gallon-stationary-air-compressor-safety-information/646541.png","ImageObject",300,407,{"name":92,"@type":93},"Marglet","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Can this compressor be used to supply breathing-quality air?","Question",{"text":112,"@type":113},"No. The compressor is not equipped for breathable air use. For any human consumption application, install suitable inline safety and alarm equipment for proper filtration and purification.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Why is repairing or modifying the tank dangerous?",{"text":117,"@type":113},"Never attempt to repair or modify a tank. Welding, drilling, or other modifications weaken the tank and can lead to rupture or explosion; replace worn or damaged tanks instead.",{"name":119,"@type":110,"acceptedAnswer":120},"What does the guide warn about electrical grounding and wiring?",{"text":121,"@type":113},"Improper electrical grounding can cause electrical shock, and wiring should be done by a qualified electrician. Follow proper electrical installation practices to avoid unsafe conditions.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646541,1792948960,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":4},2336477982702,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Item \\#1000 746 892 Model \\#HS518102  \nUSE AND CARE GUIDE  \n80-GALLON STATIONARY AIR COMPRESSOR  \nQuestions, problems, missing parts? Before returning to the store, call Husky Customer Service  \n8 a.m. -6 p.m., EST, Monday-Friday  \n1-888-43-HUSKY  \nHUSKYTOOLS.COM  \nTHANK YOU  \nWe appreciate the trust and conﬁdence you have placed in Husky through the purchase of this air compressor. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available foryour home improvement needs.  \nThankyou for choosing Husky!  \n| Table of Contents |  |  |  |\n| --- | --- | --- | --- |\n| Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 |  | Installation-Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 |  |\n| California Proposition 65 . . . . . . . . . . . . . . . . . . . . . . . . . . . | . 2 | Installation-Electrical   |   13 |\n| General Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | . 3 | Assembly. . . . . . . . . . . . . . . . . . . . . . . . |   16 |\n| Work Area Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | . 4 | Operation. . . . . . . . . . . . . . . . . . . . . . . . |   17 |\n| Personal Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | . 5 | Maintenance   |   19 |\n| Electrical Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | . 5 | Care and Cleaning . . . . . . . . . . . . . . . . |   21 |\n| Spraying Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | . 5 | Troubleshooting . . . . . . . . . . . . . . . . . . |   22 |\n| Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pre-Installation  \u003Cbr>Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hardware Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Compressor Components. . . . . . . . . . . . . . . . . . . . . . . . . . . Speciﬁcations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | . 6\u003Cbr>. 7\u003Cbr>. 7\u003Cbr>. 7\u003Cbr>. 8\u003Cbr>. 9\u003Cbr>10 | Service Parts   |   24 |\n| Safety Information |  |  |  |\n\nThis manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.  \nDANGER: Indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.  \nWARNING: Indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.  \nSafety Information (continued)  \nGENERAL SAFETY  \nDANGER: Breathable Air Warning: This compressor/pump is NOT equipped and should NOT be used “as is” to supply breathing quality air. For any application of air for human consumption, you must ﬁt the air compressor/pump with suitable in-line safety and alarm equipment. This additional equipment is necessary to properly ﬁlter and purify the air to meet minimal speciﬁcations for Grade D breathing as described in Compressed Gas Association Commodity Speciﬁcation G 7.1, OSHA 29 CFR 1910. 134, and/or Canadian Standards Associations (CSA) .  \nDisclaimer of Warranties: In the event the compressor is used for the purpose of breathing air application and proper in-line safety and alarm equipment is not simultaneously used, existing warranties are void, and the Manufacturer disclaims any liability whatsoever for any loss, personal injury, or damage.  \nDANGER: Never attempt to repair or modify a tank! Welding, drilling, or any other modiﬁcation will weaken the tank, resulting in damage from rupture or explosion. Always replace worn, cracked, or damaged tanks.  \nCAUTION: See the compressor speciﬁcation decal for maximum operating pressure. Do not operate wit","cbCaihX00yKeWUNX","https://ap.wps.com/l/cbCaihX00yKeWUNX","pdf",6963342,28,"English","# Safety Information\n## General Safety\n## Personal Safety\n## Electrical Safety","[{\"question\":\"Can this compressor be used to supply breathing-quality air?\",\"answer\":\"No. The compressor is not equipped for breathable air use. For any human consumption application, install suitable inline safety and alarm equipment for proper filtration and purification.\"},{\"question\":\"Why is repairing or modifying the tank dangerous?\",\"answer\":\"Never attempt to repair or modify a tank. Welding, drilling, or other modifications weaken the tank and can lead to rupture or explosion; replace worn or damaged tanks instead.\"},{\"question\":\"What does the guide warn about electrical grounding and wiring?\",\"answer\":\"Improper electrical grounding can cause electrical shock, and wiring should be done by a qualified electrician. Follow proper electrical installation practices to avoid unsafe conditions.\"}]","USE AND CARE GUIDE - 80-GALLON STATIONARY AIR COMPRESSOR - Safety Information | PDF",1792763837,71]