[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-382777-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-382777-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","urine-based-near-infrared-spectroscopy-analysis-reveals-a-noninvasive-and-convenient-diagnosis-method-for-cancers-a-pilot-study","Urine based near-infrared spectroscopy analysis reveals a noninvasive and convenient diagnosis method for cancers - a pilot study","","The study addresses the need for improved cancer diagnostics by evaluating a noninvasive and convenient urine-based approach. Urine near-infrared spectroscopy (NIRS) was combined with machine learning to classify cancer cases versus healthy controls. Samples from 327 participants (181 cases, 146 controls) were split into train and test sets. Multiple spectral pretreatments and two modeling strategies, partial least-squares (PLS) and linear support-vector machine (SVM), were compared. Best accuracy reached 0.844 with SVM using raw NIRS, improving to 0.862 after feature optimization.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/urine-based-near-infrared-spectroscopy-analysis-reveals-a-noninvasive-and-convenient-diagnosis-method-for-cancers-a-pilot-study/382777/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/urine-based-near-infrared-spectroscopy-analysis-reveals-a-noninvasive-and-convenient-diagnosis-method-for-cancers-a-pilot-study/382777.png","ImageObject",300,407,{"name":42,"@type":43},"Chumphorn","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-29","2026-09-24",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",6,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the purpose of this pilot study?","Question",{"text":63,"@type":64},"To explore an effective, noninvasive, and convenient cancer diagnostic tool using urine-based near-infrared spectroscopy (NIRS) combined with machine learning.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How were participants and data split for modeling?",{"text":68,"@type":64},"Urine samples from 327 participants (181 cancer cases and 146 healthy controls) were randomly divided into a training set (n=218) and a test set (n=109).",{"name":70,"@type":61,"acceptedAnswer":71},"Which models and preprocessing achieved the best prediction performance?",{"text":72,"@type":64},"Linear SVM performed best with an accuracy of 0.844 using raw NIRS, and after optimization (using the top 262 features), accuracy improved to 0.862.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},382777,1790716161,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":108,"preview_page_count":33,"preview_urls":145},2336475401981,"https://ap-avatar.wpscdn.com/avatar/22000c94efd8d5204d?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786935347598174694","Submitted 26 May 2023  \nAccepted 24 July 2023  \nPublished 31 August 2023  \nCorresponding authors Ji Zheng, [2859854552@qq.com](2859854552@qq.com)[ ](2859854552@qq.com)Zhongjian Chen, [chenzj@zjcc.org.cn](chenzj@zjcc.org.cn)  \nAcademic editor Vladimir Uversky  \nAdditional Information and Declarations can be found on page 13  \nDOI 10.7717/peerj.15895  \n Copyright 2023 Zhu et al.  \nDistributed under  \nCreative Commons CC-BY 4.0  \nOPEN ACCESS  \nUrine based near-infrared spectroscopy analysis reveals a noninvasive and convenient diagnosis method for cancers:  \na pilot study  \nJing Zhu1 , Siyu Zhang2 , Ruting Wang3 ,4 , Ruhua Fang1 , Lan Lei5 , Ji Zheng6 and Zhongjian Chen3 ,4  \n1 Department of Clinical Laboratory, Zhejiang Cancer Hospital, Hangzhou, Zhejiang, China  \n2 Department of Clinical Pharmacy, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China  \n3 Experimental Research Center, Zhejiang Cancer Hospital, Hangzhou, Zhejiang, China  \n4 Zhejiang Key Laboratory of Diagnosis & Treatment Technology on Thoracic Oncology (Lung and Esophagus), Hangzhou, Zhejiang, China  \n5 Zhejiang Hospital, Hangzhou, Zhejiang, China  \n6 Department of Radiotherapy and Chemotherapy, Ningbo No. 2 Hospital, Ningbo, Zhejiang, China  \nABSTRACT  \nBackground. The challenges in cancer diagnosis underline the need for continued research and development of new diagnostic tools and methods. This study aims to explore an effective, noninvasive, and convenient diagnostic tool using urine based near-infrared spectroscopy (NIRS) analysis combined with machine learning algorithm.  \nMethods. Urine samples were collected from a total of 327 participants, including 181 cancer cases and 146 healthy controls. These participants were randomly spit into train set (n D 218) and test set (n D 109) . NIRS analysis (4,000 􀀘 10,000 cm􀀀1) was performed for each sample in both train and test sets. Five pretreatment methods, including Savitzky-Golay (SG) smoothing, multiplicative scatter correction (MSC), baseline removal (BSL) with fitting polynomials to be used as baselines, the first derivative (DERIV1), and the second derivative (DERIV2), and combination with ``scaling'' and ``center'', were investigated. Then partial least-squares (PLS) and linear support-vector machine (SVM) classification models were established, and prediction performance was evaluated in test set.  \nResults. NIRS had greatly overlapping in peaks, and PCA analysis failed in separation between cancers and healthy controls. In modeling with urine based NIRS data, PLS model showed its highest prediction accuracy of 0.780, with DERIV2, ``scaling'' and ``center'' pretreatment, while linear SVM displayed its best prediction accuracy of 0.844, with raw NIRS. With optimization in SVM, the prediction accuracy could improve to 0.862, when the top 262 features were involved as variables.  \nDiscussion. This pilot study combining urine based NIRS analysis and machine learning is effective and convenient that might facilitate in cancer diagnosis, encouraging further evaluation with a large-size multi-center study.  \nHow to cite this article Zhu J, Zhang S, Wang R, Fang R, Lei L, Zheng J, Chen Z. 2023. Urine based near-infrared spectroscopy analysis reveals a noninvasive and convenient diagnosis method for cancers: a pilot study. PeerJ 11:e15895 [http://doi.org/10.7717/peerj.15895](http://doi.org/10.7717/peerj.15895)  \nSubjects Epidemiology, Oncology, Pathology  \nKeywords Machine learning, Diagnosis, Urine, Near-infrared spectroscopy, Partial least-squares (PLS), Support-vector machine (SVM)  \nINTRODUCTION  \nCancer is a devastating and unpredictable disease that poses a serious threat to human health and safety. The International Agency for Research on Cancer reported that there were approximately 19.3 million new cases of cancer (excluding nonmelanoma skin cancer) and 9.95 million cancer-related deaths (excluding nonmelanoma skin cancer) worldwide in 2020 (Sung et al., 2021) ","cbCaidGERz1TZflU","https://ap.wps.com/l/cbCaidGERz1TZflU","pdf",3360626,16,"English","# Abstract\n## Background\n## Methods\n## Results\n## Discussion\n# Introduction","[{\"question\":\"What is the purpose of this pilot study?\",\"answer\":\"To explore an effective, noninvasive, and convenient cancer diagnostic tool using urine-based near-infrared spectroscopy (NIRS) combined with machine learning.\"},{\"question\":\"How were participants and data split for modeling?\",\"answer\":\"Urine samples from 327 participants (181 cancer cases and 146 healthy controls) were randomly divided into a training set (n=218) and a test set (n=109).\"},{\"question\":\"Which models and preprocessing achieved the best prediction performance?\",\"answer\":\"Linear SVM performed best with an accuracy of 0.844 using raw NIRS, and after optimization (using the top 262 features), accuracy improved to 0.862.\"}]","Urine based near-infrared spectroscopy analysis reveals a noninvasive and convenient diagnosis method for cancers - a pilot study | PDF",1790252369,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/875daa83fe963a1b7c482bec5bda4ee8.webp",983,1272,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/4e661c469f4fc78e7af6859e11d5e345.webp",982,1270,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/1faa6bf27c117c65b842542a85d404a3.webp",981,1269,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/20a47767ad4f71ace7001a51c387668e.webp",980,1268]