[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662577-105":59,"doc-detail-662577-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","urban-rdp-house-plan-layout1-2023-2024","Urban RDP House Plan Layout1 - 2023-2024","","Urban RDP house plan layout specification covering site boundaries and building line setbacks, with window and door schedules listing approved materials, ironmongery, frames, finishes, glazing types, and quantities. Includes project notes for foundations, brick pillars, apron and stoep levels, filling and insect poison requirements, floor screed finish, wall construction mortar ratios, internal and external plaster and paint systems, brickforce detailing, and damp-proof membrane under the floor slab for moisture control.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/urban-rdp-house-plan-layout1-2023-2024/662577/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/urban-rdp-house-plan-layout1-2023-2024/662577.png","ImageObject",300,407,{"name":92,"@type":93},"adawds","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What information is provided for windows in the schedule?","Question",{"text":112,"@type":113},"The window schedule lists opening descriptions, types, ironmongery, steel window frames, finishes, glazing thickness and type, and the required quantities.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What does the door schedule specify?",{"text":117,"@type":113},"The door schedule provides door numbers, sizes/openings, descriptions, door and frame types, finish systems, approved locks, and the quantity for each door.",{"name":119,"@type":110,"acceptedAnswer":120},"Which key construction and finishing requirements are included in the notes?",{"text":121,"@type":113},"Notes cover foundations and engineered inspection, pillar and apron/stoep levels, filling and insect poison, screed finish, wall mortar ratios, internal/external plaster and paint undercoats, brickforce placement, and damp-proof membrane under the floor slab.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662577,1793220455,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},3985747872983,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","SITE BOUNDARY LINE  \nSITE BOUNDARY LINE  \n1m Rear Building Line (TBC-varies per Municipality)  \n5m Front Building Line (TBC-varies per Municipality)  \nSITE BOUNDARY LINE  \nSITE BOUNDARY LINE 1:50 SIDE ELEVATION  \n\n| WINDOW SCHEDULE |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| OPENING | DISCRIPTION | TYPE | IRONMONGERY | FRAME | FINISH | GLAZING | QUANTITY |\n| | Standard residential, hot dipped galvanized mild steel window. SABS approved | ND4 | CP catches and sliding stays | Clisco type ND4 steel window frame\u003Cbr>(1mm) or equal approved. | Touch up red oxide factory primer & apply\u003Cbr>1 x Undercoat for steel\u003Cbr>2 x Coats final non-drip enamel paint | 4mm thick Clear glass\u003Cbr>All putty to be treated with a hardener & finished off with 1 x universal undercoat &\u003Cbr>2 x Coats final\u003Cbr>non-drip enamel paint | 3 |\n| | Standard residential, hot dipped galvanized mild steel window. SABS approved | NC2 | CP catches and sliding stays | Clisco type NC2 steel window frame\u003Cbr>(1mm) or equal approved. | Touch up red oxide factory primer & apply\u003Cbr>1 x Undercoat for steel\u003Cbr>2 x Coats final non-drip enamel paint | 4mm thick Clear glass\u003Cbr>All putty to be treated with a hardener & finished off with 1 x universal undercoat &\u003Cbr>2 x Coats final\u003Cbr>non-drip enamel paint | 1 |\n| | Standard residential, hot dipped galvanized mild steel window. SABS approved | NC1 | CP catches and sliding stays | Clisco type NC1 steel window frame\u003Cbr>(1mm) or equal approved. | Touch up red oxide factory primer & apply\u003Cbr>1 x Undercoat for steel\u003Cbr>2 x Coats final non-drip enamel paint | 4mm obscured glass\u003Cbr>All putty to be treated with a hardener & finished off with 1 x universal undercoat & 2 x Coats final non-drip enamel paint | 1 |\n\n| DOOR SCHEDULE |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| DOOR NO. | OPENING |  |  |  | DISCRIPTION | TYPE | FRAME | FINISH | QUANTITY |\n| D1 | \u003Cbr>\u003Cbr>Weather bar |  |  |  | Galvanised steel door frame | External door:\u003Cbr>813mm x 2032mm x 40mm Meranti framed ledged, braced and battened. With 20 x 76mm V-jointed. 4mm flush boarding including 50 x 76mm weather bar. To receive varnish\u003Cbr>3 lever SABS approved mortice lock | 1.6mm pressed steel doorframe single rebated, with 2 paired hinges. One coat of factory primer paint must be applied to frame before despatch. | Door:\u003Cbr>Prepare surface and apply:\u003Cbr>2 x Coats Satin gloss Varnish Sanded down between coats\u003Cbr>Frame:\u003Cbr>Touch up red oxide factory primer & apply\u003Cbr>1 x Undercoat for steel\u003Cbr>2 x Coats final non-drip enamel paint | 2 |\n|  |  |  | 2032 |  |  |  |  |  |  |\n|  |  |  813  |  |  |  |  |  |  |  |\n| D2 |  |  |  |  | Galvanised steel door frame | Internal door:\u003Cbr>813mm x 2032mm x 40mm hollow core flush panel door with Masonite finish and concealed hardwood edges. To receive paint 3 lever SABS approved mortice lock | 1.6mm pressed steel doorframe single rebated, with 2 paired hinges. One coat of factory primer paint must be applied to frame before despatch. | Door:\u003Cbr>Prepare surface and apply:\u003Cbr>1 x Approved undercoat\u003Cbr>2 x Approved Non-drip Enamel paint\u003Cbr>Frame:\u003Cbr>Touch up red oxide factory primer & apply\u003Cbr>1 x Undercoat for steel\u003Cbr>2 x Coats final non-drip enamel paint | 3 |\n|  |  |  |  |  |  |  |  |  |  |\n|  |  |  | 2032 |  |  |  |  |  |  |\n|  |  | 813 |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |\n\nNOTES:  \n1. Foundations:  \n1.1 Foundations (to be designed as per geo-tech soil classification), by a registered Professional Engineer Foundations shall be inspected and certified by a registered Professional Engineer.  \n1.2 Brick pillar:  \nFooting as per Engineer's specification and details  \n290mm x 290mm Pillar using 140mm thick cement Maxi bricks (290mm x 140mm x 90mm) or of equal quality and approved, with minimum compressive strength of 7mpa on 375micron DPC. Pillar to receive 15mm thick smooth sand / cement plaster. Neatly plastered  \n1.3 Apron:  \n1000mm wide x 100mm thick concr","cbCaisKhL5SGPTal","https://ap.wps.com/l/cbCaisKhL5SGPTal","pdf",578776,"English","# Site and Building Lines\n## Window Schedule\n## Door Schedule\n# Notes and Construction Requirements\n## Foundations\n## Filling and Floor\n## Wall Construction and Plaster/Paint\n## Brickforce and Waterproofing","[{\"question\":\"What information is provided for windows in the schedule?\",\"answer\":\"The window schedule lists opening descriptions, types, ironmongery, steel window frames, finishes, glazing thickness and type, and the required quantities.\"},{\"question\":\"What does the door schedule specify?\",\"answer\":\"The door schedule provides door numbers, sizes/openings, descriptions, door and frame types, finish systems, approved locks, and the quantity for each door.\"},{\"question\":\"Which key construction and finishing requirements are included in the notes?\",\"answer\":\"Notes cover foundations and engineered inspection, pillar and apron/stoep levels, filling and insect poison, screed finish, wall mortar ratios, internal/external plaster and paint undercoats, brickforce placement, and damp-proof membrane under the floor slab.\"}]","Urban RDP House Plan Layout1 - 2023-2024 | PDF"]