[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-500272-105":59,"doc-detail-500272-en":134},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":127,"head_meta":129,"extra_data":131,"updated_unix":133},105,"en","unidrive-sp-size-6-and-7-installation-sheet","Unidrive SP size 6 and 7 - Installation Sheet","","Installation sheet for Unidrive SP free standing drives with switch disconnector, covering size 6 and size 7 ratings and electrical connections. Provides normal-duty and heavy-duty maximum continuous output current, nominal motor power at 400V and 460V, peak currents, and temperature notes for E23 variants and standard drives. Includes connection guidance (top entry only), warnings about live wiring behind panels, removal/guard replacement steps, and tables for input/output cable size ratings and fuse specifications, plus module code explanations and AC supply limits.",{"@graph":69,"@context":126},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/unidrive-sp-size-6-and-7-installation-sheet/500272/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/unidrive-sp-size-6-and-7-installation-sheet/500272.png","ImageObject",300,407,{"name":92,"@type":93},"cryingin4k","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-14","2026-10-03",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118,122],{"name":109,"@type":110,"acceptedAnswer":111},"What are the key current and power ratings for Unidrive SP size 6 and 7?","Question",{"text":112,"@type":113},"The sheet lists maximum continuous output current, nominal power at 400V and motor power at 460V, and peak currents for multiple models under both normal duty and heavy duty conditions.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Why is the AC supply entry restricted, and what must be done after installing cables?",{"text":117,"@type":113},"Only top entry is supported for AC power supply cables. After the supply cables are installed, the guard must be replaced, and the sheet warns that cables behind the panel remain permanently live.",{"name":119,"@type":110,"acceptedAnswer":120},"How do you choose input cable sizes and installation category?",{"text":121,"@type":113},"Use the provided tables matching the drive model to the recommended European and USA cable gauges, including the installation category (IEC-based) and the cable installation method key (C/F/G).",{"name":123,"@type":110,"acceptedAnswer":124},"What fuse ratings and limits apply to these drives?",{"text":125,"@type":113},"The document provides mains fuse ratings and control fuse ratings by model (including specific manufacturer part examples). It also states the integral incomer options must not be used in circuits capable of delivering more than 30kA.","https://schema.org",{"og:url":83,"og:type":128,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":130,"canonical":83},"index,follow",{"doc_id":132,"site_id":62},500272,1791224866,{"code":4,"msg":5,"data":135},{"doc_id":132,"user_id":136,"nickname":92,"user_avatar":137,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":138,"file_id":139,"file_url":140,"file_type":141,"file_size":142,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":19,"language":143,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":144,"faqs":145,"seo_title":146,"seo_description":67,"update_tm":147,"read_time":52},137458181193,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","2.  \n\n| \u003Cbr>| Unidrive SP size 6 and 7 Free Standing drive with switch disconnector Installation Sheet |\n| --- | --- |\n\nRatings at 40°C (104°F) or 33°C (91°F) for E23 variants  \n\n| Model |  | Normal Duty |  |  |  | Heavy Duty |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  | Maximum\u003Cbr>continuous\u003Cbr>output current | Nominal\u003Cbr>power\u003Cbr>at 400V | Motor\u003Cbr>power\u003Cbr>at 460V | Peak\u003Cbr>current | Maximum\u003Cbr>continuous\u003Cbr>output current | Open loop\u003Cbr>peak\u003Cbr>current | Closed\u003Cbr>loop peak\u003Cbr>current | Nominal\u003Cbr>power\u003Cbr>at 400V | Motor\u003Cbr>power\u003Cbr>at 460V |\n|  |  | A | kW | hp | A | A | A | A | kW | hp |\n| | 64X1 | 205 | 110 | 150 | 226 | 180 | 232 | 270 | 90 | 150 |\n|  | 64X2 | 236 | 132 | 200 | 260 | 210 | 271 | 315 | 110 | 150 |\n|  | 74X1 | 290 | 160 | 250 | 319 | 238 | 307 | 357 | 132 | 200 |\n|  | 74X2 | 350* | 200 | 280 | 369 | 290 | 374 | 435 | 160 | 250 |\n|  | 66X1 | 125 | 110 | 125 | 138 | 100 | 129 | 150 | 90 | 100 |\n|  | 66X2 | 144 | 132 | 150 | 158 | 125 | 161 | 188 | 110 | 125 |\n|  | 76X1 | 168 | 160 | 150 | 185 | 144 | 186 | 216 | 132 | 150 |\n|  | 76X2 | 192 | 185 | 200 | 211 | 168 | 217 | 252 | 160 | 150 |\n\n* at 35°C (95°F) for standard drive, 30°C (86°F) for E23 drives  \nFigure 1-1 Unidrive SP size 6 and 7 Free Standing drive with switch disconnector  \nFigure 1-2 Removing the Unidrive SP size 6 and 7 Free Standing drive with switch disconnector panels  \nFigure 1-3 Features of the Unidrive SP size 6 and 7 Free Standing drive with switch disconnector  \nAC supply connections  \nNote TOP ENTRY ONLY  \nGround connections  \ndisconnector  \nBraking terminals (size 7)  \nMotor connections  \nGround  \nconnections   \nBraking terminals (size 6)  \nInternal fuse location  \nFigure 1-4 Removal of switch disconnector guard on size 6 and 7  \nFree Standing drive with switch disconnector  \nRemove guard to access AC input terminals for initial installation  \nCables behind this panel will be permanently live. This panel must not be removed without isolating from the power source  \nNOTE  \nUnidrive SP size 6 and 7 only support top entry for AC power supply cables. The guard must be replaced once the supply cables have been installed.  \nFigure 1-5 Top down view of Unidrive SP size 6 and 7 Free Standing drive with switch disconnector  \nGland AC power supply cables to this roof plate  \nFront of drive  \nFigure 1-6 Recommended position of roof gland plate through holes for Unidrive SP size 6 and 7 Free Standing drive with switch disconnector input cable  \nAll wiring and glanding to be constructed to wiring regulations in the intended country of use.  \nTable 1-2 Unidrive SP size 6 and 7 Free Standing drive with switch disconnector input current and cable size ratings  \n\n| Model | European input and output cables |  |  |  | USA input & output cables |\n| --- | --- | --- | --- | --- | --- |\n|  | Largest IEC |  | Smallest IEC |  |  |\n|  | Cable gauge (mm2) | Installation category* | Cable gauge (mm2) | Installation\u003Cbr>category* | USA wire gauge\u003Cbr>(Kcmil/AWG) |\n| 64X1 | 1 X 120 | C | 1 X 70 | G | 1 x 300 kcmil |\n| 64X2 | 1 X 150 | C | 1 X 95 | G | 1 x 350 kcmil |\n| 74X1 | 1 X 185 | C | 1 X 120 | G | 1 x 500 kcmil |\n| 74X2 | 1 X 240 | C | 1 X 150 | G | 2 x 4/0 AWG |\n| 66X1 | 1 X 50 | C | 1 X 35 | G | 1 x 2/0 AWG |\n| 66X2 | 1 X 70 | C | 1 X 50 | G | 1 x 3/0 AWG |\n| 76X1 | 1 X 95 | C | 1 X 50 | G | 1 x 4/0 AWG |\n| 76X2 | 1 X 95 | C | 1 X 70 | G | 1 x 250 kcmil |\n\n* Installation method ref: IEC60364-5-52:2001  \nTable 1-3 Unidrive SP size 6 and 7 Free Standing drive with switch disconnector mains and control fuse rating  \n\n| Model | Mains fuse rating |  |  |  |  | Control fuse rating |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  | Fuse\u003Cbr>IEC aR | Ferraz |  | Bussmann |  | Bussmann |  |  |\n|  |  | CT Part No. | Manufacturer Part No. | CT Part No. | Manufacturer\u003Cbr>Part No. | Fuse rating | CT Part No. | Manufacturer\u003Cbr>Part No. |\n| 64X1 | 400A | 4300-0400 | 6,6 URD32D08A0400 | 3533-4069 | 170M3019 | 2","cbCaijEhz2cq0Cp1","https://ap.wps.com/l/cbCaijEhz2cq0Cp1","pdf",1392580,"English","# Ratings and current limits\n## Normal duty vs heavy duty ratings\n# Installation and connection requirements\n## Top entry AC supply only\n## Live panel warning and guard replacement\n# Wiring and cable selection\n## Input current and cable size ratings (EU/USA)\n## Cable installation key (C/F/G)\n# Fuses and module code\n## Mains and control fuse ratings\n## Module code explanation","[{\"question\":\"What are the key current and power ratings for Unidrive SP size 6 and 7?\",\"answer\":\"The sheet lists maximum continuous output current, nominal power at 400V and motor power at 460V, and peak currents for multiple models under both normal duty and heavy duty conditions.\"},{\"question\":\"Why is the AC supply entry restricted, and what must be done after installing cables?\",\"answer\":\"Only top entry is supported for AC power supply cables. After the supply cables are installed, the guard must be replaced, and the sheet warns that cables behind the panel remain permanently live.\"},{\"question\":\"How do you choose input cable sizes and installation category?\",\"answer\":\"Use the provided tables matching the drive model to the recommended European and USA cable gauges, including the installation category (IEC-based) and the cable installation method key (C/F/G).\"},{\"question\":\"What fuse ratings and limits apply to these drives?\",\"answer\":\"The document provides mains fuse ratings and control fuse ratings by model (including specific manufacturer part examples). It also states the integral incomer options must not be used in circuits capable of delivering more than 30kA.\"}]","Unidrive SP size 6 and 7 - Installation Sheet | PDF",1791009985]