[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-459368-105":59,"doc-detail-459368-en":134},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":127,"head_meta":129,"extra_data":131,"updated_unix":133},105,"en","ultra-sensitive-spear-immunoassay-with-cross-platform-qpcr-consistency-for-neurodegenerative-biomarker-measurement","Ultra-Sensitive SPEAR Immunoassay with Cross-Platform qPCR Consistency for Neurodegenerative Biomarker Measurement","","Neurodegenerative diseases such as Alzheimer’s require highly sensitive and specific diagnostic tools for early detection and monitoring. Immunoassay-based detection of disease-associated biomarkers in biofluids is promising yet limited by sensitivity, reproducibility, and scalability. This study introduces a semi-automated SPEAR (Successive Proximity Extension Amplification Reaction) immunoassay workflow that delivers consistent results across different qPCR instruments. A washfree, homogeneous process with real-time PCR supports automation integration and enables high-throughput biomarker analysis for key AD targets.",{"@graph":69,"@context":126},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ultra-sensitive-spear-immunoassay-with-cross-platform-qpcr-consistency-for-neurodegenerative-biomarker-measurement/459368/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ultra-sensitive-spear-immunoassay-with-cross-platform-qpcr-consistency-for-neurodegenerative-biomarker-measurement/459368.png","ImageObject",300,407,{"name":92,"@type":93},"Levi","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-07","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118,122],{"name":109,"@type":110,"acceptedAnswer":111},"What problem does the SPEAR-based immunoassay address for neurodegenerative diagnostics?","Question",{"text":112,"@type":113},"It targets the need for highly sensitive, specific biomarker detection while improving sensitivity, reproducibility, and scalability for early diagnosis and monitoring.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the workflow demonstrate cross-platform consistency?",{"text":117,"@type":113},"It shows consistent sample readings across multiple qPCR instruments, indicating robustness in different laboratory settings and platforms.",{"name":119,"@type":110,"acceptedAnswer":120},"Which Alzheimer’s disease biomarkers were tested in clinical plasma samples?",{"text":121,"@type":113},"The study tested phosphorylated tau (p-Tau 217, p-Tau 231), neurofilament light chain (NfL), and glial fibrillary acidic protein (GFAP).",{"name":123,"@type":110,"acceptedAnswer":124},"What performance metrics support the assay’s precision?",{"text":125,"@type":113},"The workflow enables high-precision quantification in a single-digit femtomolar range, with intra- and inter-assay coefficients of variation (CV) below 10%.","https://schema.org",{"og:url":83,"og:type":128,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":130,"canonical":83},"index,follow",{"doc_id":132,"site_id":62},459368,1790755795,{"code":4,"msg":5,"data":135},{"doc_id":132,"user_id":136,"nickname":92,"user_avatar":137,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":138,"file_id":139,"file_url":140,"file_type":141,"file_size":142,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":143,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":144,"faqs":145,"seo_title":146,"seo_description":67,"update_tm":133,"read_time":24,"preview_page_count":14,"preview_urls":147},7971461740909,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","DOI: 10. 1002/alz70856_106773  \nBIOMARKERS  \nPOSTER PRESENTATION  \nBIOMARKERS (NON-NEUROIMAGING)  \nUltra-Sensitive SPEAR Immunoassay with Cross-Platform qPCR Consistency for Neurodegenerative Biomarker Measurement  \nDarren Yang1   \nCorinne Thomas2  \nXue Jiang 1  Yunfei  Wenjing Jiang2   \nNiu 1  Zixuan Qu 1  WonHee Jeremy Tan2  Feng Xuan2  \nKim2  \n1Spear Bio, Woburn, MA, USA  \n2SPEAR BIO INC, Woburn, MA, USA  \nCorrespondence  \nDarren Yang, Spear Bio, Woburn, MA, USA. [Email:](Email: darren.yang@spear.bio)[ darren.yang@spear.bio](Email: darren.yang@spear.bio)  \nAbstract  \nBackground: Neurodegenerative diseases such as Alzheimer’s disease (AD) require highly sensitive and specific diagnostic tools for early detection and monitoring. Immunoassay-based detection of disease-associated biomarkers in biofluids shows promise but faces challenges in sensitivity, reproducibility, and scalability. Our study presents a semi-automated immunoassay workflow powered by SPEAR (Successive Proximity Extension Amplification Reaction) technology to enhance detection capabilities and enable high-throughput biomarker analysis. Robustness was demonstrated through consistent results across different qPCR instruments, highlighting the method’s adaptability in diverse laboratory settings.  \nMethod: The core SPEAR technology employs a 2-factor authentication mechanism to minimize background from non-specific interactions and uses a homogeneous, washfree workflow with a real-time PCR readout. This design facilitates straightforward integration into automation systems without requiring proprietary equipment. The majority of the workflow was automated on a Formulatrix F.A.S.T™ liquid handler using only 1 µL of diluted sample and paired with multiple qPCR instruments to demonstrate cross-platform consistency. Clinical plasma samples were tested for key AD biomarkers, including phosphorylated tau (p-Tau 217, p-Tau 231), neurofilament light chain (NfL), and glial fibrillary acidic protein (GFAP).  \nResult: The SPEAR-based semi-automated workflow enables high-precision quantification of low-abundance biomarkers in single-digit femtomolar (fM) range. Intra- and inter-assay coefficients of variation (CV) were below 10%, and sample readings were consistent across different qPCR platforms, confirming the assay’s robustness and scalability.  \nThis is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.  \n© 2025 The Alzheimer’s Association. Alzheimer’s & Dementia published by Wiley Periodicals LLC on behalf of Alzheimer’s Association.  \nAlzheimer’s Dement. 2025;21(Suppl. 2):e106773.  \n[https://doi.org/10.1002/alz70856_106773](https://doi.org/10.1002/alz70856_106773)  \nwi[leyonlinelibrary.com/journal/alz](leyonlinelibrary.com/journal/alz)  \n1of2  \nBIOMARKERS  \nConclusion: This SPEAR-powered semi-automated immunoassay workflow advances biomarker quantification for neurodegenerative disease diagnostics by improving sensitivity, reducing operator variability, and supporting high-throughput processing. Its cross-platform consistency underscores the assay’s versatility in diverse laboratory environments. The platform’s ability to detect low-abundance biomarkers from minimal sample volumes positions it as a valuable tool for both clinical and research applications.","cbCaifm6IH7NMjUN","https://ap.wps.com/l/cbCaifm6IH7NMjUN","pdf",89094,"English","# Background\n# Method\n## SPEAR technology workflow\n## Automation and sample requirements\n# Results\n# Conclusion","[{\"question\":\"What problem does the SPEAR-based immunoassay address for neurodegenerative diagnostics?\",\"answer\":\"It targets the need for highly sensitive, specific biomarker detection while improving sensitivity, reproducibility, and scalability for early diagnosis and monitoring.\"},{\"question\":\"How does the workflow demonstrate cross-platform consistency?\",\"answer\":\"It shows consistent sample readings across multiple qPCR instruments, indicating robustness in different laboratory settings and platforms.\"},{\"question\":\"Which Alzheimer’s disease biomarkers were tested in clinical plasma samples?\",\"answer\":\"The study tested phosphorylated tau (p-Tau 217, p-Tau 231), neurofilament light chain (NfL), and glial fibrillary acidic protein (GFAP).\"},{\"question\":\"What performance metrics support the assay’s precision?\",\"answer\":\"The workflow enables high-precision quantification in a single-digit femtomolar range, with intra- and inter-assay coefficients of variation (CV) below 10%.\"}]","Ultra-Sensitive SPEAR Immunoassay with Cross-Platform qPCR Consistency for Neurodegenerative Biomarker Measurement | PDF",[148,152],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/df2e426b09f03b72e626b63b6e7e68f0.webp",983,1291,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/83502e8a95a94bdac428fd519d588417.webp",982,1290]