[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646502-105":59,"doc-detail-646502-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","ultra-miniature-ir-smart-probe-sp-001-readme-and-setup-guide","Ultra Miniature IR Smart Probe - SP-001 - Readme and setup guide","","Ultra Miniature IR Smart Probe User’s Guide covers safe installation, software setup, and communication for the SP-001/SP-002. The guide explains probe positioning, distance and spot size, ambient temperature and atmospheric quality considerations, and factors affecting electrical interference. It provides procedures for configuring emissivity (including known values and table-based methods), adjusting spike/noise suppression, and setting alarms. Appendix includes an emissivity table and safety/regulatory compliance information.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ultra-miniature-ir-smart-probe-sp-001-readme-and-setup-guide/646502/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ultra-miniature-ir-smart-probe-sp-001-readme-and-setup-guide/646502.png","ImageObject",300,407,{"name":92,"@type":93},"Elsa","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-23",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What does the Omega Smart IR Temperature Probe measure and how?","Question",{"text":111,"@type":112},"It is a miniature infrared sensor that measures the surface temperature of a solid or liquid without contact. It also includes a built-in sensor to measure the ambient temperature of the probe itself.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What emissivity configuration options are provided for the probe?",{"text":116,"@type":112},"The guide covers setting emissivity using a known emissivity value, using an emissivity table, or using a secondary temperature device.",{"name":118,"@type":109,"acceptedAnswer":119},"What safety and usage warnings must be followed?",{"text":120,"@type":112},"The equipment protection may be impaired if used outside the manual’s specified manner. The guide instructs not to operate in flammable or explosive environments and to read and follow all safety and EMC-related precautions.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},646502,1792762992,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":138,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":128,"read_time":143},137455077381,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","User’s Guide  \nShop online at [omega.com](omega.com)  \ne-mail: [info@omega.com](info@omega.com)  \n[For latest product manuals:](For latest product manuals:)[ ](For latest product manuals:)[www.omegamanual.info](www.omegamanual.info)  \nSP-001, SP-002  \nUltra Miniature IR Smart Probe  \n[omega.com](omega.com) [info@omega.com](info@omega.com)  \n[Servicing North America:](Servicing North America:)  \nU.S.A. Omega Engineering, Inc.  \nHeadquarters: 800 Connecticut Ave. Suite 5N01, Norwalk, CT 06854  \nToll-Free: 1-800-826-6342 (USA & Canada only)  \nCustomer Service: 1-800-622-2378 (USA & Canada only)  \nEngineering Service: 1-800-872-9436 (USA & Canada only)  \nTel: (203) 359-1660 Fax: (203) 359-7700  \ne-mail: [info@omega.com](info@omega.com)  \nThe information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.  \nTable of Contents  \nNotes Warnings, and Cautions ....................................................................................... 4  \nIntroduction ................................................................................................................... 5  \nDescription................................................................................................................ 5  \nIncluded with Your SP-001 / SP-002 .......................................................................... 5  \nAdditional Material Needed...................................................................................... 5  \nOptional Materials .................................................................................................... 5  \nManuals / Software................................................................................................... 5  \nInput / Output Pin Layout .............................................................................................. 6  \nOptical Chart .................................................................................................................. 6  \nPreparation .................................................................................................................... 7  \nPositioning ................................................................................................................ 7  \nDistance and Spot Size .............................................................................................. 7  \nAmbient Temperature .............................................................................................. 7  \nAtmospheric Quality ................................................................................................. 7  \nElectrical Interference ............................................................................................... 7  \nMechanical Installation .................................................................................................. 8  \nSoftware Setup .............................................................................................................. 8  \nConnecting to Omega Sync – Automatic Detect........................................................ 8  \nConnecting to Omega Sync – Manual ....................................................................... 8  \nCommunication Interface ......................................................................................... 9  \nSetting Emissivity ..........................................................................................................10  \nKnown Emissivity Value .......................................................................................... 10  \nSetting Emissivity via Emissivity Table ..................................................................... 10  \nSetting Emissivity via Secondary Temperature Device ............................................ 10  \nAdjusting Spike and Noise Suppression .........................................................................11  \nAlarm","cbCaidfkcdnQsVbN","https://ap.wps.com/l/cbCaidfkcdnQsVbN","pdf",15295190,17,"English","# Notes Warnings, and Cautions\n# Introduction\n## Description\n## Included with Your SP-001 / SP-002\n## Additional Material Needed\n## Optional Materials\n## Manuals / Software\n# Input / Output Pin Layout\n# Optical Chart\n# Preparation\n## Positioning\n## Distance and Spot Size\n## Ambient Temperature\n## Atmospheric Quality\n## Electrical Interference\n# Mechanical Installation\n# Software Setup\n## Connecting to Omega Sync – Automatic Detect\n## Connecting to Omega Sync – Manual\n# Communication Interface\n# Setting Emissivity\n## Known Emissivity Value\n## Setting Emissivity via Emissivity Table\n## Setting Emissivity via Secondary Temperature Device\n# Adjusting Spike and Noise Suppression\n# Alarm Setting\n# Appendix A-Emissivity Table\n# Specifications\n## Safety and Regulatory Compliance","[{\"question\":\"What does the Omega Smart IR Temperature Probe measure and how?\",\"answer\":\"It is a miniature infrared sensor that measures the surface temperature of a solid or liquid without contact. It also includes a built-in sensor to measure the ambient temperature of the probe itself.\"},{\"question\":\"What emissivity configuration options are provided for the probe?\",\"answer\":\"The guide covers setting emissivity using a known emissivity value, using an emissivity table, or using a secondary temperature device.\"},{\"question\":\"What safety and usage warnings must be followed?\",\"answer\":\"The equipment protection may be impaired if used outside the manual’s specified manner. The guide instructs not to operate in flammable or explosive environments and to read and follow all safety and EMC-related precautions.\"}]","Ultra Miniature IR Smart Probe - SP-001 - Readme and setup guide | PDF",43]