[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-468818-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-468818-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","uhrms-formula-assignment-diophantine-based-recalibration-yields-lorentzian-mass-error-distribution-as-the-limiting-factor","UHRMS Formula Assignment - Diophantine-Based Recalibration Yields Lorentzian Mass Error Distribution as the Limiting Factor","","Ultrahigh-resolution mass spectrometry (UHRMS) is used to analyze complex molecular mixtures, often relying on Fourier transform methods such as FTICR-MS or FT-Orbitrap-MS. Despite advanced instrumentation, nontargeted spectral interpretation remains difficult because mass errors and calibration limitations complicate molecular formula assignment. This work introduces a Diophantine approach that uses statistical knowledge of random mass error, separating systematic calibration error from random peak-position error, yielding a quantifiable Lorentzian mass-error distribution and self-consistent formula assignments near theoretical accuracy limits.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/uhrms-formula-assignment-diophantine-based-recalibration-yields-lorentzian-mass-error-distribution-as-the-limiting-factor/468818/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/uhrms-formula-assignment-diophantine-based-recalibration-yields-lorentzian-mass-error-distribution-as-the-limiting-factor/468818.png","ImageObject",300,407,{"name":42,"@type":43},"Bintang","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-17","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What problem does the paper target in UHRMS molecular formula assignment?","Question",{"text":63,"@type":64},"It addresses the difficulty of interpreting complex, nontargeted spectra where incorrect or incomplete calibration and mass error behavior hinder reliable molecular formula attribution.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How does the Diophantine method help with calibration versus random mass error?",{"text":68,"@type":64},"The method considers all possible attributions over a large mass-error range to distinguish systematic calibration error from random peak-position mass error in a statistically consistent way.",{"name":70,"@type":61,"acceptedAnswer":71},"What mass-error distribution does the approach produce and why is it important?",{"text":72,"@type":64},"After correcting systematic mass errors, the remaining random mass error follows a Lorentzian distribution, matching expectations for Fourier transform-based instruments with long transients, and supporting near-theoretical accuracy in assignments.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},468818,1792235033,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},962085564381,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","ACS Partner Journal  \nThis article is licensed under CC-BY 4.0   \n[pubs.acs.org/jasms](pubs.acs.org/jasms)  Article   \nUHRMS Formula Assignment: Diophantine-Based Recalibration Yields Lorentzian Mass Error Distribution as the Limiting Factor  \nNeda Safaridehkohneh and Albrecht Ott*  \n Cite This: J. Am. Soc. Mass Spectrom. 2026, 37, 105−115  \nRead Online  \n\n|  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| ACCESS   | Metrics & More |  |  Article Recommendations |  | *sı Supporting Information |\n\nABSTRACT: Ultrahigh-resolution mass spectrometry (UHRMS) is a well-established analytical method for characterizing complex molecular mixtures. It is usually performed with Fourier transform techniques, based either on ion cyclotron resonance (FTICR-MS) or mass-dependent oscillations in an ion trap (FT-Orbitrap-MS). In spite of the high technical level of these instruments, often spectral interpretation remains difficult, in particular in anontargeted approach of complex samples. Here, we introduce a Diophantine method for molecular formula assignment. Taking the ubiquitous Gaussian distribution as an example, we first show how knowledge about random mass error can be used to assign molecular formulas in a statistically consistent way. By considering all possible attributions within a large mass error range, we show how the systematic error stemming from suboptimal calibration  \ncan be distinguished from the random mass error in peak position. Correcting for systematic mass error leaves us with a quantifiable, Lorentzian random mass error as expected for Fourier transform-based instruments with long transients. This indicates that our method is self-consistent, assigning molecular formulas close to the theoretical limit of achievable accuracy.  \n1. INTRODUCTION  \nUltrahigh-resolution mass spectrometry (UHRMS), typically exceeding a resolving power of 100,000, is performed on Fourier transform ion cyclotron resonance (FTICR-MS) and Fourier transform Orbitrap (FT-Orbitrap) instruments. It is a powerful analytical tool, widely used to characterize complex chemical mixtures from various sources, including the environment, biological matter, synthetic compounds, pharmaceutical products, as well as the petroleum industry1−5 . UHRMS promises to identify, in a single measurement, a huge number of molecular compounds (up to a few ten thousands) within a complex sample. This type of information can be crucial, for instance, in nontargeted assessments of toxicity of intricate molecular mixtures. It can be of great help in prebiotic scenarios6. This is among many other settings that concern complex mixtures of molecules in industrial applications or scientific research.  \nA significant large-scale effort to evaluate the reproducibility of measurements and assignments by different groups with different instruments highlighted the critical need for reliable assignment methods7−11. Interpreting complex spectra in anontargeted approach remains challenging. Several advanced molecular formula assignment methods have been developed. These include licensed based methods (e.g., Composer from Sierra Analytics, PetroOrg12) as well as open-source database related methods (e.g., UltraMassExplorer (UME),13 FuJHA,14 Formularity15). However, completeness and correctness of the  \n© 2025 The Authors. Published by American Chemical Society  \ndatabase are crucially important. Up to 30% of spectra in the NIST EI mass spectral database were claimed to be incorrectly assigned 16. There are also open-source calculation methods (e.g., CHO-FIT17−19) that do not require a database. A strong limitation in the assignment process stems from the combinatorial explosion accompanying higher mass molecules made of several atomic species, making purely calculative approaches challenging. Graph theoretical - and Diophantine approaches have yielded elegant methods for improvement20−22 . The CHOFIT method17, 18 used low mass moieties limited to CHO, leading to excellent resul","cbCaidQ9ZGSpQJe0","https://ap.wps.com/l/cbCaidQ9ZGSpQJe0","pdf",4983363,11,"English","# Abstract\n# Introduction\n## UHRMS and Fourier transform instruments\n## Challenges in nontargeted formula assignment\n## Calibration, space-charge effects, and peak shape\n## Error sources: finite residence time and Lorentzian peaks","[{\"question\":\"What problem does the paper target in UHRMS molecular formula assignment?\",\"answer\":\"It addresses the difficulty of interpreting complex, nontargeted spectra where incorrect or incomplete calibration and mass error behavior hinder reliable molecular formula attribution.\"},{\"question\":\"How does the Diophantine method help with calibration versus random mass error?\",\"answer\":\"The method considers all possible attributions over a large mass-error range to distinguish systematic calibration error from random peak-position mass error in a statistically consistent way.\"},{\"question\":\"What mass-error distribution does the approach produce and why is it important?\",\"answer\":\"After correcting systematic mass errors, the remaining random mass error follows a Lorentzian distribution, matching expectations for Fourier transform-based instruments with long transients, and supporting near-theoretical accuracy in assignments.\"}]","UHRMS Formula Assignment - Diophantine-Based Recalibration Yields Lorentzian Mass Error Distribution as the Limiting Factor | PDF",1790774724,28,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/7d7f0cd9330de2c040701f98ceb930bb.webp",983,1296,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/027104824ff63b351c81b3ceb55ab953.webp",982,1295,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ddb1f36f6d4a7a0e234d1e2c8ba0a7b0.webp",981,1293,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c41146bf5e2133e416a11982a072c731.webp",980,1292]