[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-501898-105":59,"doc-detail-501898-en":134},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":127,"head_meta":129,"extra_data":131,"updated_unix":133},105,"en","uc900-ss23-cat7-lshf-fr-dca-technical-cable-specifications-version-10","UC900 SS23 Cat.7 LSHF-FR Dca - Technical Cable Specifications - Version 1.0","","Technical specifications for UC900 SS23 Category 7 S/FTP cabling with LSHF-FR fire-retardant sheath, covering conductor and insulation construction, shielding, and cable lay-up. Includes application guidance for primary (campus), secondary (riser), and tertiary (horizontal) installations, supported Ethernet/fieldbus use, and compliance references (e.g., EN/ISO/IEC standards). Provides mechanical limits such as bending radius and temperature ranges, plus detailed electrical performance at 20°C across frequency, covering resistance, capacitance, propagation delay, attenuation, NEXT/PS-NEXT, ACR, return loss, and order/product code tables.",{"@graph":69,"@context":126},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/uc900-ss23-cat7-lshf-fr-dca-technical-cable-specifications-version-10/501898/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/uc900-ss23-cat7-lshf-fr-dca-technical-cable-specifications-version-10/501898.png","ImageObject",300,407,{"name":92,"@type":93},"Rowan","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-19","2026-10-03",true,{"@type":102,"interactionType":103,"userInteractionCount":39},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118,122],{"name":109,"@type":110,"acceptedAnswer":111},"What cable construction is specified for UC900 SS23 Cat.7 LSHF-FR Dca?","Question",{"text":112,"@type":113},"The document specifies bare copper conductors (Ø 0.56 mm, AWG 23/1), foamskin PE insulation (Ø 1.38 mm), 2 cores twisted to form pairs, aluminum-laminated plastic foil pair screening, and a copper braid screen with an LSHF-FR orange sheath.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What mechanical and temperature limits are provided?",{"text":117,"@type":113},"It lists bending radius requirements without load (4 x D) and with load (8 x D), plus operation temperature range of -20°C to +60°C and installation range of 0°C to +50°C. A note indicates bending radius applies only for LSHF-FR.",{"name":119,"@type":110,"acceptedAnswer":120},"Which electrical performance parameters and frequency-based results are included?",{"text":121,"@type":113},"The specifications include loop resistance, insulation resistance, mutual capacitance, characteristic impedance, propagation delay, delay skew, transfer impedance, coupling attenuation, and segregation classification. It also provides frequency tables for attenuation, NEXT, PS-NEXT, ACR, PS-ACR, ACRF, PS-ACRF, and return loss for nominal Cat.7 at 20°C.",{"name":123,"@type":110,"acceptedAnswer":124},"How can product variants be ordered using the reference codes?",{"text":125,"@type":113},"The document lists product order data with reference codes, outer diameters, Euro class/fire load, weight, copper content, and tensile force, followed by a product code table mapping product descriptions to PG reference codes and part numbers (e.g., 60015274 and 60016105 with multiple variants).","https://schema.org",{"og:url":83,"og:type":128,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":130,"canonical":83},"index,follow",{"doc_id":132,"site_id":62},501898,1791269559,{"code":4,"msg":5,"data":135},{"doc_id":132,"user_id":136,"nickname":92,"user_avatar":137,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":138,"file_id":139,"file_url":140,"file_type":141,"file_size":142,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":143,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":144,"faqs":145,"seo_title":146,"seo_description":67,"update_tm":147,"read_time":39},1099514067415,"https://ap-avatar.wpscdn.com/avatar/100002539d78ffe74a7?x-image-process=image/resize,m_fixed,w_180,h_180&k=1779092875211072502","UC900 SS23 Cat.7 LSHF-FR Dca  \nS/FTP AWG23/1  \nDca  \nCPR  \nEca  \nCPR  \nApplication  \nPrimary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM  \nPower over Ethernet (PoE) / PoE+  \nEN 50173-1; EN 50288-4-1 ISO/IEC 11801; IEC 61156-5 IEEE 802. 3af  \nFlame resistance  \nEN 50399: Class Dcas2d1a1; Class Eca  \nLSHF-FR(FRNC): IEC 60332-3-24; IEC 60332-1; 60754-2; IEC 61034  \nConstruction  \n\n| Conductor | bare copper wire, Ø 0.56 mm (AWG 23/1) |\n| --- | --- |\n| Insulation | Foamskin PE, Ø 1.38 mm |\n| Twisting | 2 cores to the pair |\n| Pair screen | Al-laminated plastic foil |\n| Cable lay up | 4 pairs (PiMF) to the core |\n| Screen | copper braid, tinned |\n| Sheath | LSHF-FR, orange |\n\nMechanical properties  \n\n| Bending radius |  | without load | 4 x D |\n| --- | --- | --- | --- |\n|  |  | with load | 8 x D |\n| Temperature range |  | during operation | -20°C to + 60°C |\n|  |  | during installation | 0°C to + 50°C |\n| * | Only for LSHF-FR |  |  |\n\nDRAKA  \nUC  \n[www.prysmiangroup.com](www.prysmiangroup.com)  \nuc09ss23FRDca e Version 1.0 | 28.06.2017 Page 1 of 3  \nUC900 SS23 Cat.7 LSHF-FR Dca  \nElectrical properties at 20°C± 5°C  \n\n| Loop resistance |  | 154 Ω/km |  |\n| --- | --- | --- | --- |\n| Resistance unbalance |  | ≤ 2% |  |\n| Insulation resistance | (500 V) | ≥ 5000 MΩ* km |  |\n| Mutual capacitance | at 800 Hz | Nom . 43 nF/km |  |\n| Capacitance unbalance | (pair/ground) | ≤ 1500 pF/km |  |\n| Mean characteristic impedance | 100 MHz | 100 ± 5 Ω |  |\n| Nominal velocity of propagation |  | ca. 79 % |  |\n| Propagation delay |  | ≤ 427 ns/100m |  |\n| Delay skew |  | ≤ 12 ns/100m |  |\n| Test voltage | (DC, 1 min) core/core and core/screen | 1000 V |  |\n| Transfer impedance | bei 1 MHz | ≤ 5 mΩ /m | Grade 1 |\n|  | bei 10 MHz | ≤ 5 mΩ /m |  |\n|  | bei 30 MHz | ≤ 10 mΩ /m |  |\n| Coupling attenuation |  | ≥ 85 dB | Type 1 |\n| Segregation classification acc . EN 50174-2 |  | „D“ |  |\n\nElectrical data (nominal) acc. to Cat.7 (at 20°C)  \n\n| F\u003Cbr>(MHZ) | Attenuation\u003Cbr>(dB/100m) | NEXT\u003Cbr>(dB) | PS-NEXT\u003Cbr>(dB) | ACR\u003Cbr>(dB/100m) | PS-ACR\u003Cbr>(dB/100m) | ACRF\u003Cbr>(dB/100m) | PS-ACRF\u003Cbr>(dB/100m) | Return\u003Cbr>loss\u003Cbr>(dB) |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1,0 | 1,8 | 100 | 97 | 98 | 95 | 105 | 105 | - |\n| 4,0 | 3,4 | 100 | 97 | 97 | 94 | 105 | 102 | 27 |\n| 10,0 | 5,4 | 100 | 97 | 95 | 92 | 97 | 94 | 30 |\n| 16,0 | 6,8 | 100 | 97 | 93 | 90 | 93 | 90 | 30 |\n| 20,0 | 7,7 | 100 | 97 | 92 | 89 | 91 | 88 | 30 |\n| 31,2 | 9,6 | 100 | 97 | 90 | 87 | 87 | 84 | 30 |\n| 62,5 | 13,7 | 100 | 97 | 86 | 83 | 81 | 78 | 30 |\n| 100,0 | 17,4 | 100 | 97 | 83 | 80 | 77 | 74 | 30 |\n| 125,0 | 19,5 | 95 | 92 | 75 | 72 | 75 | 72 | 26 |\n| 155,5 | 21,9 | 94 | 91 | 72 | 69 | 73 | 70 | 26 |\n| 175,0 | 23,3 | 93 | 90 | 70 | 67 | 72 | 69 | 25 |\n| 200,0 | 25,0 | 92 | 89 | 67 | 64 | 71 | 68 | 25 |\n| 250,0 | 28,1 | 90 | 87 | 62 | 59 | 69 | 66 | 24 |\n| 300,0 | 30,9 | 89 | 86 | 58 | 55 | 67 | 64 | 24 |\n| 450,0 | 38,3 | 87 | 84 | 48 | 45 | 64 | 61 | 23 |\n| 600,0 | 44,8 | 85 | 82 | 40 | 37 | 61 | 58 | 22 |\n| 750,0 | 52,0 | 83 | 80 | 31 | 28 | 59 | 56 | 21 |\n| 900,0 | 59,4 | 82 | 79 | 23 | 20 | 58 | 55 | 20 |\n| 1000,0 | 63,1 | 80 | 77 | 17 | 14 | 57 | 54 | 20 |\n\nDRAKA  \nUC  \n[www.prysmiangroup.com](www.prysmiangroup.com)  \nuc09ss23FRDca e Version 1.0 | 28.06.2017 Page 2 of 3  \nUC900 SS23 Cat.7 LSHF-FR Dca  \nProduct order data  \n\n| Reference\u003Cbr>Code | Cable type | Brand name | Outer\u003Cbr>diameter\u003Cbr>mm | Euro class | Fire load |  | Weight\u003Cbr>kg/km | Copper\u003Cbr>content | Tensile\u003Cbr>force\u003Cbr>N |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  | MJ/km | kWh/ m |  |  |  |\n| 60015274 | J-02YSCH 4x2x0 .56 PiMF | UC900 SS23 Cat.7 S/FTP 4P LSHF-FR * | 7,5 | Dcas2d1a1 | 585 | 0,163 | 75 | 38 | 340 |\n| 60016105 | J-02YSCH 2x(4x2x0.56) PiMF | UC900 SS23 Cat.7 S/FTP 2x4P LSHF-FR * | 7,5/15,0 | Dcas2d1a1 | 1170 | 0,326 | 150 | 76 | 680 |\n\nProduct Code Table  \n\n| Produ","cbCaiidWatZvICKX","https://ap.wps.com/l/cbCaiidWatZvICKX","pdf",251949,"English","# Construction\n## Mechanical properties\n## Electrical properties at 20°C\n## Electrical data (nominal) by frequency\n## Product order data\n## Product code table\n## Legal and usage notes","[{\"question\":\"What cable construction is specified for UC900 SS23 Cat.7 LSHF-FR Dca?\",\"answer\":\"The document specifies bare copper conductors (Ø 0.56 mm, AWG 23/1), foamskin PE insulation (Ø 1.38 mm), 2 cores twisted to form pairs, aluminum-laminated plastic foil pair screening, and a copper braid screen with an LSHF-FR orange sheath.\"},{\"question\":\"What mechanical and temperature limits are provided?\",\"answer\":\"It lists bending radius requirements without load (4 x D) and with load (8 x D), plus operation temperature range of -20°C to +60°C and installation range of 0°C to +50°C. A note indicates bending radius applies only for LSHF-FR.\"},{\"question\":\"Which electrical performance parameters and frequency-based results are included?\",\"answer\":\"The specifications include loop resistance, insulation resistance, mutual capacitance, characteristic impedance, propagation delay, delay skew, transfer impedance, coupling attenuation, and segregation classification. It also provides frequency tables for attenuation, NEXT, PS-NEXT, ACR, PS-ACR, ACRF, PS-ACRF, and return loss for nominal Cat.7 at 20°C.\"},{\"question\":\"How can product variants be ordered using the reference codes?\",\"answer\":\"The document lists product order data with reference codes, outer diameters, Euro class/fire load, weight, copper content, and tensile force, followed by a product code table mapping product descriptions to PG reference codes and part numbers (e.g., 60015274 and 60016105 with multiple variants).\"}]","UC900 SS23 Cat.7 LSHF-FR Dca - Technical Cable Specifications - Version 1.0 | PDF",1791026541]