[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-501895-105":59,"doc-detail-501895-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","uc900-ss23-cat7-application","UC900 SS23 Cat.7 - Application","","UC900 SS23 Cat.7 S/FTP AWG23/1 cable application specification covering primary campus, secondary riser, and tertiary horizontal use with IEEE 802.3 10Base-T/100Base-T/1000Base-T/10GBase-T and related network standards. Includes compliance references for EN 50173-1, EN 50288-4-1, ISO/IEC 11801, IEC 61156-5, and IEEE 802.3af, plus flame-resistance requirements. Provides construction details (conductor, insulation, pair screening, sheath) and lists mechanical and electrical performance parameters, including attenuation, NEXT, PS-NEXT, return loss, and transfer impedance at multiple frequencies.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/uc900-ss23-cat7-application/501895/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/uc900-ss23-cat7-application/501895.png","ImageObject",300,407,{"name":92,"@type":93},"Asher","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-19","2026-10-03",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What network applications and Ethernet standards does UC900 SS23 Cat.7 support?","Question",{"text":112,"@type":113},"It targets campus/riser/horizontal deployment and supports IEEE 802.3 10Base-T, 100Base-T, 1000Base-T, and 10GBase-T, with additional listed networking standards.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which construction elements define the UC900 SS23 Cat.7 cable?",{"text":117,"@type":113},"It specifies a bare copper conductor (Ø 0.56 mm), foamskin PE insulation (Ø 1.38 mm), twisted 2-core pair layout, aluminium-laminated foil pair screen, a copper braid screen, and an LSHF or LSHF-FR orange halogen-free sheath compound.",{"name":119,"@type":110,"acceptedAnswer":120},"What electrical performance parameters are provided for Cat.7 (nominal) and how are they presented?",{"text":121,"@type":113},"The document provides frequency-dependent attenuation, NEXT, PS-NEXT, ACR and PS-ACR, ACRF and PS-ACRF, and return loss for Cat.7 at 20°C across many F values.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},501895,1791493825,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":39},687197207639,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","UC900 SS23 Cat.7  \nS/FTP AWG23/1  \nApplication  \n\n| Primary (Campus), Secondary (Riser), Tertiary (Horizontal)\u003Cbr>IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T\u003Cbr>IEEE 802.5 16 MB; ISDN; TPDDI; ATM\u003Cbr>Power over Ethernet (PoE) / PoE+\u003Cbr>Standards |\n| --- |\n| EN 50173-1; EN 50288-4-1\u003Cbr>ISO/IEC 11801; IEC 61156-5\u003Cbr>IEEE 802. 3af\u003Cbr>Flame resistance |\n\nLSHF (LSOH): IEC 60332-1; IEC 60754-2; IEC 61034  \nLSHF-FR (LSOH-FR): IEC 60332-1; IEC 60332-3-24; IEC 60754-2; IEC 61034  \nConstruction  \n\n| Conductor | bare copper wire, Ø 0.56 mm (AWG 23/1) |\n| --- | --- |\n| Insulation | Foamskin PE, Ø 1.38 mm |\n| Twisting | 2 cores to the pair |\n| Pair screen | Al-laminated plastic foil |\n| Cable lay up | 4 pairs (PiMF) to the core |\n| Screen | copper braid, tinned |\n| Sheath | LSHF, orange or\u003Cbr>LSHF-FR, orange, halogen free compound (SHF1) according IEC 60092-360 |\n\nMechanical properties  \nBending radius  \nTemperature range  \nwithout load  \nwith load  \nduring operation  \nduring installation  \n4 x D  \n8 x D  \n-20°C to + 60°C 0°C to + 50°C  \n76 UC900 SS23 Cat.7  \nElectrical properties at 20°C± 5°C  \n\n| Loop resistance |  | 154 Ω/km |  |\n| --- | --- | --- | --- |\n| Resistance unbalance |  | 􀁤 2% |  |\n| Insulation resistance | (500 V) | 􀁴 2000 MΩ*km |  |\n| Mutual capacitance | at 800 Hz | Nom. 43 nF/km |  |\n| Capacitance unbalance | (pair/ground) | 􀁤 1500 pF/km |  |\n| Mean characteristic impedance | 100 MHz | 100 ± 5 Ω |  |\n| Nominal velocity of propagation |  | ca. 79 % |  |\n| Propagation delay |  | 􀁤 427 ns/100m |  |\n| Delay skew |  | 􀁤 12 ns/100m |  |\n| Test voltage | (DC, 1 min) core/core and core/screen | 1000 V |  |\n| Transfer impedance | bei 1 MHz | 􀁤 5 mΩ /m | Grade 1 |\n|  | bei 10 MHz | 􀁤 5 mΩ /m |  |\n|  | bei 30 MHz | 􀁤 10 mΩ /m |  |\n| Coupling attenuation |  | 􀁴 85 dB | Type 1 |\n| Segregation classification acc. EN 50174-2 |  | „D“ |  |\n\nElectrical data (nominal) acc. to Cat.7 (at 20°C)  \n\n| F\u003Cbr>(MHZ) | Attenuation\u003Cbr>(dB/100m) | NEXT\u003Cbr>(dB) | PS-NEXT\u003Cbr>(dB) | ACR\u003Cbr>(dB/100m) | PS-ACR\u003Cbr>(dB/100m) | ACRF\u003Cbr>(dB/100m) | PS-ACRF\u003Cbr>(dB/100m) | Return loss\u003Cbr>(dB) |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1,0 | 1,8 | 100 | 97 | 98 | 95 | 105 | 105 | - |\n| 4,0 | 3,4 | 100 | 97 | 97 | 94 | 105 | 102 | 27 |\n| 10,0 | 5,4 | 100 | 97 | 95 | 92 | 97 | 94 | 30 |\n| 16,0 | 6,8 | 100 | 97 | 93 | 90 | 93 | 90 | 30 |\n| 20,0 | 7,7 | 100 | 97 | 92 | 89 | 91 | 88 | 30 |\n| 31,2 | 9,6 | 100 | 97 | 90 | 87 | 87 | 84 | 30 |\n| 62,5 | 13,7 | 100 | 97 | 86 | 83 | 81 | 78 | 30 |\n| 100,0 | 17,4 | 100 | 97 | 83 | 80 | 77 | 74 | 30 |\n| 125,0 | 19,5 | 95 | 92 | 75 | 72 | 75 | 72 | 26 |\n| 155,5 | 21,9 | 94 | 91 | 72 | 69 | 73 | 70 | 26 |\n| 175,0 | 23,3 | 93 | 90 | 70 | 67 | 72 | 69 | 25 |\n| 200,0 | 25,0 | 92 | 89 | 67 | 64 | 71 | 68 | 25 |\n| 250,0 | 28,1 | 90 | 87 | 62 | 59 | 69 | 66 | 24 |\n| 300,0 | 30,9 | 89 | 86 | 58 | 55 | 67 | 64 | 24 |\n| 450,0 | 38,3 | 87 | 84 | 48 | 45 | 64 | 61 | 23 |\n| 600,0 | 44,8 | 85 | 82 | 40 | 37 | 61 | 58 | 22 |\n| 750,0 | 52,0 | 83 | 80 | 31 | 28 | 59 | 56 | 21 |\n| 900,0 | 59,4 | 82 | 79 | 23 | 20 | 58 | 55 | 20 |\n| 1000,0 | 63,1 | 80 | 77 | 17 | 14 | 57 | 54 | 20 |\n\nProduct order data  \n\n| Product\u003Cbr>code | Cable type | Brand name | Outer\u003Cbr>diameter\u003Cbr>mm | Fire load |  | Weight\u003Cbr>kg/km | Copper\u003Cbr>content | Tensile\u003Cbr>force\u003Cbr>N |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  | MJ/km | kWh/m |  |  |  |\n| 1001032 | J-02YSCH 4x2x0,56 PiMF | UC900 SS23 Cat.7 S/FTP 4P LSHF | 7,5 | 585 | 0,163 | 75 | 38 | 340 |\n| 1001033 |  | UC900 SS23 Cat.7 S/FTP 4PLSHF-FR |  |  |  |  |  |  |\n| 1001034 | J-02YSCH 2x(4x2x0.56) PiMF | UC900 SS23 Cat.7 S/FTP 2x4PLSHF | 7,5/15,0 | 1170 | 0,326 | 150 | 76 | 680 |\n| 1001035 |  | UC900 SS23 Cat.7 S/FTP 2x4PLSHF-FR |  |  |  |  |  |  |\n\nUC900 SS23 Cat.7 77  \nProduct Code Table  \n\n| Product Description | Product Code | PG Reference Code | PG Part Number |\n| --- | --- | --- | --- |\n| UC900 SS23 C7 S/FTP 4P LSHF | 1001032 | 60011543 | 60011543 |\n| UC900 SS23 ","cbCail6ReApTmG5P","https://ap.wps.com/l/cbCail6ReApTmG5P","pdf",260876,"English","# Application\n## Standards and requirements\n## Cable construction\n## Mechanical properties\n## Electrical properties and performance tables\n## Product order data","[{\"question\":\"What network applications and Ethernet standards does UC900 SS23 Cat.7 support?\",\"answer\":\"It targets campus/riser/horizontal deployment and supports IEEE 802.3 10Base-T, 100Base-T, 1000Base-T, and 10GBase-T, with additional listed networking standards.\"},{\"question\":\"Which construction elements define the UC900 SS23 Cat.7 cable?\",\"answer\":\"It specifies a bare copper conductor (Ø 0.56 mm), foamskin PE insulation (Ø 1.38 mm), twisted 2-core pair layout, aluminium-laminated foil pair screen, a copper braid screen, and an LSHF or LSHF-FR orange halogen-free sheath compound.\"},{\"question\":\"What electrical performance parameters are provided for Cat.7 (nominal) and how are they presented?\",\"answer\":\"The document provides frequency-dependent attenuation, NEXT, PS-NEXT, ACR and PS-ACR, ACRF and PS-ACRF, and return loss for Cat.7 at 20°C across many F values.\"}]","UC900 SS23 Cat.7 - Application | PDF",1791026458]