[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-562580-105":59,"doc-detail-562580-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","tx-relays-specifications-high-capacity-relay","TX-Relays - Specifications - High Capacity Relay","","TX-RELAYS datasheet specifications for a 2A high capacity relay designed for high surge and high breakdown voltage applications. The document lists contact and coil parameters including initial contact resistance, gold-clad silver alloy contact material, nominal resistive switching capacity (2 A at 30 V DC), switching power and limits, and UL/CSA ratings. It provides ordering information, breakdown/surge withstand levels between contacts and coil, insulation resistance, operating and release timing, speed, temperature range, shock and vibration resistance, and unit weight. It also includes pickup/drop-out voltage and coil operating data for multiple terminal types and coil voltages.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/tx-relays-specifications-high-capacity-relay/562580/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/tx-relays-specifications-high-capacity-relay/562580.png","ImageObject",300,407,{"name":92,"@type":93},"RuangKosong","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What are the main contact and switching ratings for the TX-Relays?","Question",{"text":113,"@type":114},"The relay provides nominal resistive switching capacity of 2 A at 30 V DC, with max switching power of 60 W and max switching voltage up to 220 V DC. Minimum switching capability is 10 μA at 10 mV DC.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What breakdown voltage and surge withstand values are specified between contacts and coil?",{"text":118,"@type":114},"The document specifies breakdown voltage between contacts and coil as 2,000 V and surge withstand as 2,500 V, along with additional surge values for different test conditions between open contacts and across contact sets.",{"name":120,"@type":111,"acceptedAnswer":121},"Which coil terminal types and coil voltage options are covered in the TX-Relays datasheet?",{"text":122,"@type":114},"The document includes standard PC board terminal type, self-clinching terminal type, and surface-mount terminal options. It provides coil voltage selections (e.g., 1.5, 3, 4.5, 5, 6, 9, 12, 24, and 48 V) with corresponding drop-out/pick-up and operating function data.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},562580,1792251564,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},962090883219,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","TX  \nmm inch  \n# SPECIFICATIONS\n\nContact  \n\n| Arrangement   |  |  | 2 Form C   |\n| --- | --- | --- | --- |\n| Initial contact resistance,max.  \u003Cbr>(By voitage drop 6V DC 1 A)   |  |  | 100 mΩ   |\n| Contact material   |  |  | Gold-clad silver alloy   |\n| Rating   | Nominal switching capacity  \u003Cbr>(resistive)   |  | 2 A 30V DC   |\n|  | Max.switching power  \u003Cbr>(resistive)   |  | 60 W   |\n|  | Max.switching voltage   |  | 220VDC   |\n|  | Max.switching current   |  | 2A   |\n|  | Min.switching capability   |  | 10μA 10 mV DC   |\n| UL/CSA rating   |  |  | 2 A30 V DC  \u003Cbr>0.3 A110V DC  \u003Cbr>0.5 A 125VAC   |\n| Expected  \u003Cbr>life(min.  \u003Cbr>opera-  \u003Cbr>tions)   | Mechanical (at 180 cpm)   |  | 108   |\n|  | Electrical  \u003Cbr>(at 20 cpm)   | 2 A 30V DC  \u003Cbr>resistive   | 10⁵   |\n|  |  | 1A30VDC  \u003Cbr>resistive   | 5×10⁵   |\n\n# ORDERING INFORMATION\n\nNotes:1.48V coil type is available only for single side stable type.  \n2.Tape and reel packing is also available for surface-mount type by request.Part number suffix\"-X\"or\"-Z\"isneeded when ordening.In this case,“X\"or\"Z are not marked on the relay.Quantity in tape and reel:500 pcs.ex)·T⁷×2SA-3V-Pced tom th 13415-pin side  \n910-478十910-491  \n\n| NAiS   | 2 AMP.HIGH CAPACITY  \u003Cbr>RELAY WITH HIGH SURGE  \u003Cbr>VOLTAGE &HIGH BREAK-  \u003Cbr>DOWN VOLTAGE   | TX-RELAYS   |\n| --- | --- | --- |\n\nUL File NoE43149CSA File No.:LR26550  \n·Breakdown voltage between contacts and coil:2,000V  \n·Surge withstand between contacts and coil:2,500 V  \n·High contact capacity:2A30V DC  \n·Surface-mount type available  \n# Characteristics\n\n\n| Max.operating speed (at rated load)   |  |  | 20 cpm   |\n| --- | --- | --- | --- |\n| Operate time*1 (at nominal voltage)   |  |  | Max.4 msec.(Approx.2 msec.)   |\n| Release time1(at nominal voltage)   |  |  | Max.4 msec.(Approx.1 msec.)   |\n| Set time*¹(latching)(at nominal voltage)   |  |  | Max.4 msec.(Approx.2 msec.)   |\n| Reset time¹(latching)(at nominal volitage)   |  |  | Max.4 msec.(Approx.2 msec.)   |\n| lnitial  \u003Cbr>breakdown  \u003Cbr>voltage   | Between open contacts   |  | 1,000 Vrms for 1 min.   |\n|  | Between contact sets   |  | 1,000 Vrms for 1 min.   |\n|  | Between contact and coil   |  | 2,000 Vrms for 1 min.   |\n| Surge  \u003Cbr>voltage   | Between open contacts  \u003Cbr>(10×160 μsec)   |  | 1,500V(FCC Part 68)   |\n|  | Between contacts and  \u003Cbr>coil(2×10μsec)   |  | 2,500 V(Bellcore)   |\n| Initial insulation resistance   |  |  | Min.1,000 MΩ(at 500 V DC)   |\n| Temperature rise*2   |  |  | Max.50℃   |\n| Ambient temperature   |  |  | -40℃ to+85℃  \u003Cbr>-40 F to+185°F(up to 24 V cil)  \u003Cbr>-40℃ to +70℃  \u003Cbr>-40'F to+158 F(48 V coil)  \u003Cbr>(Not freezing and condens-  \u003Cbr>ing at low temperature)   |\n| Shock resistance   |  | Functional   | Min.750 m/sec²(75G)   |\n|  |  | Destructive   | Min.1,000 m/s²(100 G)   |\n| Vibration resistance   |  | Functional   | 196m/s²(20G),10 to 55 Hzat  \u003Cbr>double amplitude of 3.3 mm   |\n|  |  | Destructive   | 294 m/s²(30G),10 to 55Hzat  \u003Cbr>double amplitude of 5 mm   |\n| Unit weight   |  |  | Approx.2g.071 oz   |\n\n*1 Excluding contact bouncing time  \n2 Measured under the flow of nominal operating current at nominal voltage  \n\n|  | H  \u003Cbr>SA  \u003Cbr>Ex.TX  \u003Cbr>L  \u003Cbr>2   |  |  |  | 3V   |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  |  |  |  |\n| Contact arrangement   |  | Surface-mount availabliity   | Operating function   | Terminal shape   |  | Coil voltage(DC)   |  |\n| 2:2 Form C   |  | Nil:Standard PC board ter-  \u003Cbr>minal type or self-clinching  \u003Cbr>terminal type  \u003Cbr>SA:Surface-mount ter-  \u003Cbr>minal type   | Nil:Single side stable  \u003Cbr>L:1 coil latching  \u003Cbr>L2:2 coil latching   | Nil:Standard PC board  \u003Cbr>terminal or surface-  \u003Cbr>mount terminal  \u003Cbr>H:Self-clinching  \u003Cbr>terminal   |  | 1.5,3,4.5,5,6,  \u003Cbr>9,12,24,48V   |  |\n\n   ·TX2SA-L-3V-ZPicked fromte B9I10Y12-pin sie                      \n# TYPES AND COIL DATA(at 20℃ 68F)\n\n## 1)Standard PC board terminal type and self-clinching terminal type\n\nMax.  \nNominal  \nPart No.  \nNominal  \nC","cbCaipZNPticLTlU","https://ap.wps.com/l/cbCaipZNPticLTlU","pdf",572860,"English","# Specifications\n## Ordering Information\n## Characteristics\n## Types and Coil Data","[{\"question\":\"What are the main contact and switching ratings for the TX-Relays?\",\"answer\":\"The relay provides nominal resistive switching capacity of 2 A at 30 V DC, with max switching power of 60 W and max switching voltage up to 220 V DC. Minimum switching capability is 10 μA at 10 mV DC.\"},{\"question\":\"What breakdown voltage and surge withstand values are specified between contacts and coil?\",\"answer\":\"The document specifies breakdown voltage between contacts and coil as 2,000 V and surge withstand as 2,500 V, along with additional surge values for different test conditions between open contacts and across contact sets.\"},{\"question\":\"Which coil terminal types and coil voltage options are covered in the TX-Relays datasheet?\",\"answer\":\"The document includes standard PC board terminal type, self-clinching terminal type, and surface-mount terminal options. It provides coil voltage selections (e.g., 1.5, 3, 4.5, 5, 6, 9, 12, 24, and 48 V) with corresponding drop-out/pick-up and operating function data.\"}]","TX-Relays - Specifications - High Capacity Relay | PDF",1791809011,18,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/54aa465c1f27fa1b1a29edc83d64f77f.webp",983,1390,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d200549c48c832e7830b576be901b0c5.webp",982,1389,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/7c6a55b10de3522eaff046c33b311615.webp",981,1387,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2c07cdd8da08fbe4d6c4220e925099b5.webp",980,1386]