[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-378070-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-378070-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","two-year-follow-up-of-participants-in-the-breastscreen-victoria-pilot-trial-of-tomosynthesis-versus-mammography-breast-density-stratified-screening-outcomes","Two-year follow-up of participants in the BreastScreen Victoria pilot trial of tomosynthesis versus mammography: breast density-stratified screening outcomes","","Follow-up results from BreastScreen Victoria’s pilot trial of digital breast tomosynthesis (DBT) report interval cancer rates, screening sensitivity, and breast density–stratified outcomes compared with mammography. A prospective, non-randomised design recruited women ≥40 years undergoing DBT, with concurrent mammography participants used as a comparison group. Interval cancer ascertainment used 24-month follow-up from the screen date and automated breast density measurement. Findings show higher sensitivity with DBT, higher cancer detection and recall particularly in high-density screens, with no significant difference in interval cancer rates overall.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/two-year-follow-up-of-participants-in-the-breastscreen-victoria-pilot-trial-of-tomosynthesis-versus-mammography-breast-density-stratified-screening-outcomes/378070/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/two-year-follow-up-of-participants-in-the-breastscreen-victoria-pilot-trial-of-tomosynthesis-versus-mammography-breast-density-stratified-screening-outcomes/378070.png","ImageObject",300,407,{"name":42,"@type":43},"Jordan Avery","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-24","2026-09-24",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",13,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What was the objective of this two-year follow-up study?","Question",{"text":63,"@type":64},"To estimate interval cancer rates and screening sensitivity for tomosynthesis versus mammography, and to assess density-stratified screening outcomes using automated breast density measurement.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How was the comparison between tomosynthesis and mammography groups performed?",{"text":68,"@type":64},"The study used a prospective pilot trial where women undergoing DBT formed one cohort, while concurrent screening participants receiving mammography provided the comparison group.",{"name":70,"@type":61,"acceptedAnswer":71},"What were the main screening performance findings after 24 months?",{"text":72,"@type":64},"Tomosynthesis showed significantly higher sensitivity than mammography. Overall interval cancer rates did not significantly differ, while cancer detection and recall increases were predominantly seen in high-density screens.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},378070,1790529544,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":112,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":118,"preview_page_count":33,"preview_urls":145},1099523882367,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","BJR [https://doi.org/10.1259/bjr.20230081](https://doi.org/10.1259/bjr.20230081)  \n\n| \u003Cbr>Received:\u003Cbr>25 January 2023\u003Cbr>Accepted:\u003Cbr>18 April 2023\u003Cbr>Published online:\u003Cbr>25 May 2023\u003Cbr>© 2023 The Authors. Published by the British Institute of Radiology under the terms of the Creative Commons Attribution-NonCommercial 4.0 Unported License [http://creativecommons.org/l](http://creativecommons.org/l)icenses/by-nc/4 .0/, which permits unrestricted non-commercial reuse, provided the original author and source are credited.\u003Cbr>Cite this article as:\u003Cbr>Houssami N, Lockie D, Giles M, Noguchi N, Marr G, Marinovich ML. Two-year follow-up of participants in the BreastScreen Victoria pilot trial of tomosynthesis versus mammography: breast density-stratified screening outcomes. Br J Radiol (2023) 10.1259/bjr.20230081. |  |\n| --- | --- |\n| FULL PAPER\u003Cbr>Two-year follow-up of participants in the BreastScreen Victoria pilot trial of tomosynthesis versus mammography: breast density-stratified screening outcomes\u003Cbr>1,2NEHMAT HOUSSAMI, MBBS, PhD, 3DARREN LOCKIE, MBBS, 3MICHELLE GILES, BAppSc, 2NAOMI NOGUCHI, PhD, 4GEORGINA MARR, GradDip (EpiBiostats) and 1,2M LUKE MARINOVICH, PhD\u003Cbr>1The Daffodil Centre, the University of Sydney, a joint venture with Cancer Council NSW, Sydney, Australia\u003Cbr>2Sydney School of Public Health, Faculty of Medicine & Health, University of Sydney, Sydney, Australia\u003Cbr>3Maroondah BreastScreen, Eastern Health, Victoria, Australia\u003Cbr>4BreastScreen Victoria, Victoria, Australia\u003Cbr>Address correspondence to: Prof Nehmat Houssami\u003Cbr>E-mail: [nehmat.houssami@sydney.edu.au](nehmat.houssami@sydney.edu.au) |  |\n| Objective: This follow-up study of BreastScreen Victoria’s pilot trial of digital breast tomosynthesis aimed to report interval cancer rates, screening sensitivity, and density-stratified outcomes for tomosynthesis vs mammography screening.\u003Cbr>Methods: Prospective pilot trial [ACTRN- 12617000947303] in Maroondah BreastScreen recruited females ≥ 40 years presenting for screening (August 2017–November 2018) to DBT; concurrent screening participants who received mammography formed a comparison group. Follow-up of 24 months from screen date was used to ascertain interval cancers; automated breast density was measured.\u003Cbr>Results: There were 48 screen-detected and 9 interval cancers amongst 4908 tomosynthesis screens, and 34 screen-detected and 16 interval cancers amongst 5153 mammography screens. Interval cancer rate was 1. 8/1000 (95%CI 0.8–3. 5) for tomosynthesis vs 3.1/1000 (95%CI 1.8–5.0) for mammography (p = 0.20) . Sensitivity of tomosynthesis (86 .0%; 95% CI 74.2–93.7) was\u003Cbr>significantly higher than mammography (68 .0%; 95% CI 53.3–80. 5), p = 0.03. Cancer detection rate (CDR) of 9. 8/1000 (95%CI 7.2–12. 9) for tomosynthesis was higher than that of 6. 6/1000 (95%CI 4.6–9.2) for mammography (p = 0.08); density-stratified analyses showed CDR was significantly higher for tomosynthesis than mammography (10 . 6/1000 vs 3. 5/1000, p = 0.03) in high-density screens. Recall rate for tomosynthesis was significantly higher than for mammography (4 .2% vs 3.0%, p \u003C 0.001), and this increase in recall for tomosynthesis was evident only in high-density screens (5 . 6% vs 2. 9%, p \u003C 0.001) . Conclusion: Although interval cancer rates did not significantly differ between screened groups, sensitivity was significantly higher for tomosynthesis than mammography screening.\u003Cbr>Advances in knowledge: In a program-embedded pilot trial, both increased cancer detection and recall rates from tomosynthesis were predominantly observed in high-density screens. |  |\n| INTRODUCTION\u003Cbr>In the context of growing adoption and evaluation of digital breast tomosynthesis (DBT), 1 a pilot trial was undertaken in Australia’s BreastScreen program to examine detection metrics and the feasibility of DBT screening.2 Obtaining evidence from local screening programs was relevant given that initial studies of DBT, both prospective and retrospective, showed ","cbCaisaBIETG4x23","https://ap.wps.com/l/cbCaisaBIETG4x23","pdf",577720,"English","# Objective\n# Methods\n## Trial design and population\n# Results\n# Conclusion\n# Advances in knowledge\n# Introduction\n# Methods\n## Trial design and population","[{\"question\":\"What was the objective of this two-year follow-up study?\",\"answer\":\"To estimate interval cancer rates and screening sensitivity for tomosynthesis versus mammography, and to assess density-stratified screening outcomes using automated breast density measurement.\"},{\"question\":\"How was the comparison between tomosynthesis and mammography groups performed?\",\"answer\":\"The study used a prospective pilot trial where women undergoing DBT formed one cohort, while concurrent screening participants receiving mammography provided the comparison group.\"},{\"question\":\"What were the main screening performance findings after 24 months?\",\"answer\":\"Tomosynthesis showed significantly higher sensitivity than mammography. Overall interval cancer rates did not significantly differ, while cancer detection and recall increases were predominantly seen in high-density screens.\"}]","Two-year follow-up of participants in the BreastScreen Victoria pilot trial of tomosynthesis versus mammography: breast density-stratified screening outcomes | PDF",1790228259,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/a7e762357fe6e8240894f99a378d7911.webp",983,1390,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/6ce4683b46fdada71c1ff4208610166f.webp",982,1388,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/9f546bf76055e3e011d226852e5b245f.webp",981,1387,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/3ef838736cd33690f392eede698cda7c.webp",980,1385]