[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646968-105":59,"doc-detail-646968-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","two-stage-variable-speed-ecm-blower-motor-35-tall-high-efficiency-condensing-gas-furnace-fg9mve-service-and-technical-support-manual","Two-Stage, Variable Speed ECM Blower Motor 35” Tall, High Efficiency Condensing Gas Furnace - (F/G)9MVE - Service and Technical Support Manual","","Service and technical support guidance for a two-stage, variable-speed ECM blower motor 35-inch tall, high-efficiency condensing gas furnace model (F/G)9MVE. Covers safety labeling and the use of DANGER, WARNING, CAUTION, and NOTE statements, plus safety-alert symbol interpretation. Provides structured procedures for startup, setup switches, priming condensate trap with water, purging gas lines, adjustments, safety control checks, airflow and temperature rise settings, and ongoing service and maintenance tasks including cleaning, wiring, and troubleshooting.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/two-stage-variable-speed-ecm-blower-motor-35-tall-high-efficiency-condensing-gas-furnace-fg9mve-service-and-technical-support-manual/646968/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/two-stage-variable-speed-ecm-blower-motor-35-tall-high-efficiency-condensing-gas-furnace-fg9mve-service-and-technical-support-manual/646968.png","ImageObject",300,407,{"name":92,"@type":93},"Maya Linwood","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-07","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What do DANGER, WARNING, CAUTION, and NOTE mean in this manual?","Question",{"text":112,"@type":113},"DANGER indicates immediate hazards that can result in severe personal injury or death. WARNING and CAUTION describe hazards that could cause serious or minor injury and/or damage, while NOTE highlights suggestions that improve installation, reliability, or operation.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What safety actions are required before performing installation or service?",{"text":117,"@type":113},"Follow all safety codes, wear safety glasses, protective clothing, and work gloves, and have a fire extinguisher available. Read and follow all warnings and cautions included in the manual and attached to the unit.",{"name":119,"@type":110,"acceptedAnswer":120},"What topics are covered in the startup, adjustment, and safety check section?",{"text":121,"@type":113},"The manual includes setup switches, priming the condensate trap with water, purging gas lines, temperature rise and blower off-delay adjustments, cooling airflow and continuous fan airflow settings, thermostat heat anticipator adjustment, safety control checks, and a checklist.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646968,1792940830,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":4},962084928432,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","SERVICE AND TECHNICAL SUPPORT MANUAL  \nTwo−Stage, Variable Speed ECM Blower Motor 35” Tall, High Efficiency Condensing Gas Furnace  \n(F/G)9MVE  \nSave this manual for future reference.  \n\n| Safety Labeling and Signal Words |  |\n| --- | --- |\n| DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on product labels to signify an immediate hazard. The signal words WARNING, CAUTION, and NOTE will be used on product labels and throughout this manual and other manual that may apply to the product.\u003Cbr>DANGER − Immediate hazards which will result in severe personal injury or death.\u003Cbr>WARNING − Hazards or unsafe practices which could result in severe personal injury or death.\u003Cbr>CAUTION − Hazards or unsafe practices which may result in minor personal injury or product or property damage.\u003Cbr>NOTE − Used to highlight suggestions which will result in enhanced installation, reliability, or operation. | Signal Words in Manuals\u003Cbr>The signal word WARNING is used throughout this manual in the following manner:\u003Cbr>\u003Cbr> ! WARNING\u003Cbr>The signal word CAUTION is used throughout this manual in the following manner:\u003Cbr>\u003Cbr> ! CAUTION\u003Cbr>Signal Words on Product Labeling\u003Cbr>Signal words are used in combination with colors and/or pictures or product labels.\u003Cbr> Safety−alert symbol\u003Cbr>When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. |\n\nTABLE OF CONTENTS  \nSTART−UP, ADJUSTMENT, AND SAFETY CHECK ........... 4  \nSETUP SWITCHES ...................................... 4  \nPRIME CONDENSATE TRAP WITH WATER ................. 4  \nPURGE GAS LINES ...................................... 5  \nADJUSTMENTS ......................................... 5  \nADJUST TEMPERATURE RISE ............................ 11  \nADJUST BLOWER OFF DELAY (HEAT MODE) .............. 12  \nADJUST COOLING AIRFLOW ............................. 12  \nADJUST CONTINUOUS FAN AIRFLOW .................... 12  \nADJUST THERMOSTAT HEAT ANTICIPATOR ............... 14  \nCHECK SAFETY CONTROLS ............................. 14  \nCHECKLIST ............................................. 14  \nCOOLING AND HEATING AIR DELIVERY-CFM ............. 15  \nSERVICE AND MAINTENANCE PROCEDURES ............. 17  \nELECTRICAL CONTROLS AND WIRING ................... 17  \nCLEANING AND/OR REPLACING AIR FILTER .............. 19  \nBLOWER MOTOR AND WHEEL MAINTENANCE ............ 20  \nCLEANING BURNERS AND FLAME SENSOR ............... 21  \nSERVICING HOT SURFACE IGNITER ...................... 22  \nFLUSHING COLLECTOR BOX AND DRAINAGE SYSTEM .... 23  \nCLEANING CONDENSATE DRAIN AND TRAP .............. 23  \nCLEANING HEAT EXCHANGERS .......................... 23  \nSERVICE LABEL ......................................... 26  \nWIRING DIAGRAM ....................................... 27  \nTROUBLESHOOTING GUIDE − FLOW CHART .............. 28  \nSEQUENCE OF OPERATION ............................. 30  \nPARTS REPLACEMENT INFORMATION GUIDE ............. 35  \nPRODUCT NOMENCLATURE ............................. 36  \nMODELS (F/G)9MVE0401410A  \n(F/G)9MVE0601714A  \n(F/G)9MVE0801716A (F/G)9MVE0802120A  \n(F/G)9MVE1002120A  \n(F/G)9MVE1202422A  \nPrinted in U.S.A. 440 04 4800 00 Aug. 2012  \nSAFETY CONSIDERATIONS  \nImproper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory−authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing.  \nFollow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read t","cbCaifGT7QAj1ffk","https://ap.wps.com/l/cbCaifGT7QAj1ffk","pdf",2266440,36,"English","# START−UP, ADJUSTMENT, AND SAFETY CHECK\n## SETUP SWITCHES\n## PRIME CONDENSATE TRAP WITH WATER\n## PURGE GAS LINES\n## ADJUSTMENTS\n## ADJUST TEMPERATURE RISE\n## ADJUST BLOWER OFF DELAY (HEAT MODE)\n## ADJUST COOLING AIRFLOW\n## ADJUST CONTINUOUS FAN AIRFLOW\n## ADJUST THERMOSTAT HEAT ANTICIPATOR\n## CHECK SAFETY CONTROLS\n## CHECKLIST\n## COOLING AND HEATING AIR DELIVERY-CFM\n# SERVICE AND MAINTENANCE PROCEDURES\n## ELECTRICAL CONTROLS AND WIRING\n## CLEANING AND/OR REPLACING AIR FILTER\n## BLOWER MOTOR AND WHEEL MAINTENANCE\n## CLEANING BURNERS AND FLAME SENSOR\n## SERVICING HOT SURFACE IGNITER\n## FLUSHING COLLECTOR BOX AND DRAINAGE SYSTEM\n## CLEANING CONDENSATE DRAIN AND TRAP\n## CLEANING HEAT EXCHANGERS\n## SERVICE LABEL\n## WIRING DIAGRAM\n## TROUBLESHOOTING GUIDE − FLOW CHART\n## SEQUENCE OF OPERATION\n## PARTS REPLACEMENT INFORMATION GUIDE\n## PRODUCT NOMENCLATURE","[{\"question\":\"What do DANGER, WARNING, CAUTION, and NOTE mean in this manual?\",\"answer\":\"DANGER indicates immediate hazards that can result in severe personal injury or death. WARNING and CAUTION describe hazards that could cause serious or minor injury and/or damage, while NOTE highlights suggestions that improve installation, reliability, or operation.\"},{\"question\":\"What safety actions are required before performing installation or service?\",\"answer\":\"Follow all safety codes, wear safety glasses, protective clothing, and work gloves, and have a fire extinguisher available. Read and follow all warnings and cautions included in the manual and attached to the unit.\"},{\"question\":\"What topics are covered in the startup, adjustment, and safety check section?\",\"answer\":\"The manual includes setup switches, priming the condensate trap with water, purging gas lines, temperature rise and blower off-delay adjustments, cooling airflow and continuous fan airflow settings, thermostat heat anticipator adjustment, safety control checks, and a checklist.\"}]","Two-Stage, Variable Speed ECM Blower Motor 35” Tall, High Efficiency Condensing Gas Furnace - (F/G)9MVE - Service and Technical Support Manual | PDF",1792778878,91]