[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-398331-105":59,"doc-detail-398331-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","tsi-mass-flowmeters-theory-of-operation-application-note-flow-005","TSI - MASS FLOWMETERS - THEORy OF OPERATION - APPLICATION NOTE FLOW-005","","Application note FLOW-005 explains how TSI mass flowmeters use a thermal film sensor to measure gas mass flow. The heated sensor maintains constant temperature, and increasing electrical power compensates for cooling caused by gas flow. A temperature sensor upstream provides gas temperature so mass flow can be calculated. The document highlights effects from gas thermal conductivity and viscosity, the resulting non-linear flow signal, and how digital processing and calibration with a high-accuracy flow reference support measurement performance. It also describes the platinum sputtered film construction and its fast response for control systems, plus the low pressure drop benefit from a larger-diameter flow tube.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/tsi-mass-flowmeters-theory-of-operation-application-note-flow-005/398331/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/tsi-mass-flowmeters-theory-of-operation-application-note-flow-005/398331.png","ImageObject",300,407,{"name":92,"@type":93},"Grenda","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-28","2026-09-27",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",25,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"How does a TSI thermal film mass flowmeter maintain temperature control to measure mass flow?","Question",{"text":113,"@type":114},"A small electrically heated sensor is held at a constant temperature using an electronic control circuit. As gas flow cools the sensor, the control increases electrical power to maintain temperature, and the required power is proportional to gas mass flow rate.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Why is a unique calibration required for each gas or gas mixture?",{"text":118,"@type":114},"Thermal conductivity and viscosity affect heat transfer from the sensor. Because these parameters vary by gas or mixture, each requires a unique calibration.",{"name":120,"@type":111,"acceptedAnswer":121},"What role do the temperature sensor and signal processing play in computing mass flow?",{"text":122,"@type":114},"A temperature sensor upstream measures gas temperature so the two signals can be used to calculate mass flow rate. The flow signal is non-linear, and most TSI meters use a digital signal processor to linearize the output.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},398331,1790745423,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":24,"preview_page_count":14,"preview_urls":145},7971474921005,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","TSI® MASS FLOWMETERS—THEORY OF OPERATION  \nAPPLICATION NOTE FLOW-005  \nTSI mass flowmeters utilize a thermal film sensor to measure gas flow. This thermal film sensor is a typeof thermal anemometer. A thermal anemometer measures gas flow by sensing changes in heat transfer rate from a small, electrically heated sensor exposed to the gas under study. The heated sensor is held ata constant temperature using an electronic control circuit. The cooling effect resulting from the gas flowing past the sensor is compensated for by increasing the electrical power to the sensor. The magnitude of power required to keep the sensor at a constant temperature is proportional to the mass flow rate of the gas and inversely related to the temperature of the gas. A temperature sensor is mounted up stream of the flow sensor to measure the gas temperature. With these two signals a mass flow rate measurement can be calculated.  \nThermal conductivity and viscosity of the gas also affect the amount of heat transfer from the sensor. Because of the multiple parameter effect, each gas or gas mixture has a unique calibration.  \nThe flow signal is non-linear which allows for a percent of reading accuracy as opposed to most flow measurement technologies that give a percent of full-scale accuracy. Thermal anemometry flowmeters can be used to cover the same range that it would take three pressure-based flowmeters to cover. Most TSI flowmeters have a digital signal processor that linearizes the flow signal. TSI uses a high accuracy flow reference to calibrate the meter wide range of flow.  \nTSI's thermal film sensor is manufactured by sputtering a thin film of platinum on a small diameter rod. The rod gives the sensor more strength than a platinum wire, which is another similar type of thermal anemometer. The small mass of the film gives the sensor very fast response time. This fast response is ideal for closed-loop control systems and integrated volume measurements.  \nThe film sensor is highly sensitive to low velocity flows, which allows for larger diameter flow tube. The larger diameter tuber results in lower pressure drop. Lower pressure drop reduces flow circuit backpressure and its effects.  \nTSI Incorporated – Visit our website [www.tsi.com](www.tsi.com) for more information.  \nUSA  \nUK France Germany  \nTel: +1 800 874 2811  \nTel: +44 149 4 459200  \nTel: +33 4 91 11 87 64  \nTel: +49 241 523030  \nIndia China Singapore  \nTel: +91 80 67877200  \nTel: +86 10 8251 6588  \nTel: +65 6595 6388  \nFLOW-005 Rev. B ©2013 TSI Incorporated Printed in U.S.A.","cbCaib42v6qJVFr9","https://ap.wps.com/l/cbCaib42v6qJVFr9","pdf",104134,"English","# Application Note FLOW-005\n## Thermal film sensor measurement principle\n## Calibration, signal linearization, and accuracy\n## Sensor construction and system advantages","[{\"question\":\"How does a TSI thermal film mass flowmeter maintain temperature control to measure mass flow?\",\"answer\":\"A small electrically heated sensor is held at a constant temperature using an electronic control circuit. As gas flow cools the sensor, the control increases electrical power to maintain temperature, and the required power is proportional to gas mass flow rate.\"},{\"question\":\"Why is a unique calibration required for each gas or gas mixture?\",\"answer\":\"Thermal conductivity and viscosity affect heat transfer from the sensor. Because these parameters vary by gas or mixture, each requires a unique calibration.\"},{\"question\":\"What role do the temperature sensor and signal processing play in computing mass flow?\",\"answer\":\"A temperature sensor upstream measures gas temperature so the two signals can be used to calculate mass flow rate. The flow signal is non-linear, and most TSI meters use a digital signal processor to linearize the output.\"}]","TSI - MASS FLOWMETERS - THEORy OF OPERATION - APPLICATION NOTE FLOW-005 | PDF",1790477247,[146,150],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/332835cf0ee8d4413ac1b4a48ae24ad1.webp",983,1272,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/6cf45cee80e0348f0a749f4cfb065d9a.webp",982,1270]