[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-562833-105":59,"doc-detail-562833-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","toroidal-transformers-y23-standard-range-power-professional-series-specification","Toroidal Transformers - Y23 Standard Range - Power Professional Series Specification","","Toroidal transformer Y23 Standard Range specifications covering transformer connections, winding configuration limits, mounting options, insulation details, and electrical safety requirements. The document details primary/secondary parallel and series wiring constraints, general specifications such as voltage, frequency, highpot test conditions, lead construction, clearance, and multiple agency certifications. Performance is provided through efficiency and loss tables by load VA rating, plus derating guidance with regulation and temperature-rise expectations under continuous operation, along with comprehensive physical and electrical model parameters.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/toroidal-transformers-y23-standard-range-power-professional-series-specification/562833/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/toroidal-transformers-y23-standard-range-power-professional-series-specification/562833.png","ImageObject",300,407,{"name":92,"@type":93},"ahduag","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-13","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the allowed winding connection modes and related voltage limits?","Question",{"text":112,"@type":113},"Windings may be connected in parallel or in series. If the windings are isolated from each other, the applied potential between them must not exceed 250V DC.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What general electrical and test parameters are specified for the Y23 toroidal transformers?",{"text":117,"@type":113},"Primaries are specified as 115V + 115V with a 50/60 Hz frequency. Highpot testing is listed as 4K VRMS, and secondary voltage tolerance is within 3% at normal input and full load.",{"name":119,"@type":110,"acceptedAnswer":120},"How are efficiency, losses, and temperature rise presented for different load ratings?",{"text":121,"@type":113},"A table lists efficiency, copper loss, and iron loss for load VA values from 15 up to 1000. A separate derating table provides regulation and expected temperature rise under continuous conditions at lower VA ratings.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},562833,1791862999,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":19,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":52},3985747870414,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Some transformers above are shown with optional resin-ﬁlled center with threaded bushing (recommended for loads in excess of 600VA) . See page 12 for details on adding this option.  \nTransformer Connections  \nWindings may be connected in parallel or in series. If they are isolated from each other, the applied potential between them must not exceed 250V DC.  \nPrimaries and Secondaries Parallel Connected  \nBLU/VIO 0  \nGRY/BRN 115V  \n2 x I  \nBLK/ORG  \nRED/YEL  \nPrimaries and Secondaries Series Connected  \nBRN  \nBLU 0  \nGRY  \nVIO  \n230V  \nI  \n2 x V  \nBLK  \nRED ORG  \nYEL  \nPrimaries Series Connected, Secondaries Independent  \nBLU  \nGRY  \nVIO  \nBRN  \nBLK  \nRED  \nORG  \nYEL  \nAVEL’s polyester tape ﬁnish with dish mounting has proven to be the most popular method of constructing toroidal transformers for modern-day electronics.  \nThis is the most inexpensive way to meet J. I.T. schedules by purchasing “off the shelf” from the  \nwide range of toroids shown on the following pages. Y23 Range transformers are constructed to high standards, and are certiﬁed to or in compliance with most worldwide safety agency standards (see below) . Our unique double-insulated primary leads eliminate an assembly step required by many safety standards. If your requirement falls outside our Standard Range, we would be pleased to quote on a custom design (see page 11 for custom transformer speciﬁcation guidelines and request form) .  \nGeneral Speciﬁcations  \nPrimaries: 115V + 115V. Frequency: 50/60 Hz.  \nHighpot tested at: 4K VRMS.  \nSecondary voltage tolerance:  \nWithin 3% at normal input and full load.  \nMounting hardware:  \nMetal dish, 2 foam pads, bolt, washer, and nut.  \nLeads: 150 mm / 6\" (±5 mm / .2\") stranded, PVC insulated. Double-insulated primary leads: UL1672 (105˚ C, 300 V).  \nSecondary leads: UL3266 (125˚ C, 300 V)  \nClearance: allow 4 mm / .2\" over mounting hardware. Certiﬁcations: UL506/CSA 22.2, No. 66; UL1411/CSA 22.2 No. 1-94; UL1950/CSA 22.2 No. 950-95; UL2601 (UL544)/CSA 22.2 No.601. 1; CE marked and tested in accordance with EN61558 (replacing EN60742), EN60065, EN60950, BS415, VDE0550 .  \nPerformance Details  \n\n| Efﬁciency at maximum continuous VA rating |  |  |  |\n| --- | --- | --- | --- |\n| Load (VA) | Efﬁciency (%) | Copper Loss (W) | Iron loss (W) |\n| 15 | 84.8 | 2.5 | 0.2 |\n| 30 | 84.8 | 5.1 | 0.3 |\n| 50 | 86.9 | 7.1 | 0.4 |\n| 63 | 87.7 | 8.3 | 0.5 |\n| 80 | 88.9 | 9.3 | 0.7 |\n| 100 | 90.4 | 9.8 | 0.8 |\n| 120 | 90.8 | 11.3 | 0.9 |\n| 160 | 91.7 | 13.3 | 1.1 |\n| 230 | 93.0 | 15.7 | 1.5 |\n| 250 | 93.2 | 16.6 | 1.6 |\n| 330 | 94.0 | 19.2 | 1.9 |\n| 500 | 95.1 | 23.0 | 2.8 |\n| 625 | 95.4 | 26.8 | 3.3 |\n| 800 | 95.6 | 33.0 | 4.1 |\n| 1000 | 96.0 | 36.2 | 5.4 |\n\n\n| Transformers may be operated at a lower temperature with improved regulation. This table indicates temperature rise which may be expected under continuous conditions at lower VA ratings. |  |  |  |\n| --- | --- | --- | --- |\n| Derated VA\u003Cbr>From To |  | Regulation (%) | Temperature\u003Cbr>Rise (˚C) |\n| 30 | 20 | 11 | 25 |\n| 60 | 50 | 10 | 35 |\n| 100 | 75 | 8 | 35 |\n| 160 | 120 | 6 | 35 |\n| 230 | 175 | 5 | 35 |\n| 330 | 250 | 5 | 35 |\n| 500 | 400 | 4 | 40 |\n\n860/355-4711 • FAX 860/354-8597 [www.avellindberg.com](www.avellindberg.com) • [sales @avellindberg.com](sales @avellindberg.com)  \n\n| | page 7 |\n| --- | --- |\n\nToroidal Transformers  \nY23 Standard Range  \n  THE POWER PROFESSIONALS  \n\n|  Y23 configuration  | \u003Cbr>Stranded leads, 150 mm (6\") long, PVC insulated\u003Cbr>\u003Cbr>Proportions to illustrate\u003Cbr>| altered detail. |\n| --- | --- | --- |\n| Mounting Hardware Speciﬁcations Load (VA) Mounting Plate Bolt 15, 30, 50 50 mm dia. x 1 mm thick (2 .0\" dia. x .04\" thick) M5 x 40 mm 63, 80, 100, 120 70 mm dia. x 1 mm thick (2 .8\" dia. x .04\" thick) M6 x 50 mm 160, 230, 330 90 mm dia. x 1 mm thick (3 .6\" dia. x .04\" thick) M6 x 60 mm 500, 625, 800, 1000 110 mm dia. x 1 mm thick (4 .3\" dia. x .04\" thick) M6 x 80 mm All types also include 2 insulating pads, 2mm (.08\") thick (uncompressed) |  |  |\n\n\n| Y2","cbCaitn23KzxOHxN","https://ap.wps.com/l/cbCaitn23KzxOHxN","pdf",1044303,"English","# Transformer Connections\n# General Specifications\n## Safety, mounting and lead details\n# Performance Details\n## Efficiency, copper loss, iron loss\n## Temperature rise and derating\n# Toroidal Transformers - Y23 Standard Range\n## Mounting hardware specifications\n## Y23 transformer specifications","[{\"question\":\"What are the allowed winding connection modes and related voltage limits?\",\"answer\":\"Windings may be connected in parallel or in series. If the windings are isolated from each other, the applied potential between them must not exceed 250V DC.\"},{\"question\":\"What general electrical and test parameters are specified for the Y23 toroidal transformers?\",\"answer\":\"Primaries are specified as 115V + 115V with a 50/60 Hz frequency. Highpot testing is listed as 4K VRMS, and secondary voltage tolerance is within 3% at normal input and full load.\"},{\"question\":\"How are efficiency, losses, and temperature rise presented for different load ratings?\",\"answer\":\"A table lists efficiency, copper loss, and iron loss for load VA values from 15 up to 1000. A separate derating table provides regulation and expected temperature rise under continuous conditions at lower VA ratings.\"}]","Toroidal Transformers - Y23 Standard Range - Power Professional Series Specification | PDF",1791809835]