[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-641588-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-641588-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","tonoport-v-firmware-version-21-operators-manual","TONOPORT V - Firmware Version 2.1 - Operator’s Manual","","Operator’s Manual for the GE Healthcare TONOPORT V ambulatory blood pressure system firmware version 2.1. Defines intended use, patient-borne non-invasive measurement scope, and key safety information including CE marking compliance, device class, applicable standards, and symbols. Provides controls and indicators, setup procedures, application guidance with CASE™/CardioSoft operation, data output, error codes, software installation, cleaning and maintenance, disposal, technical specifications, order information, and EMC appendix, plus revision history and service manual note.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/tonoport-v-firmware-version-21-operators-manual/641588/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/tonoport-v-firmware-version-21-operators-manual/641588.png","ImageObject",300,407,{"name":42,"@type":43},"Riley West","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-13","2026-10-23",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What does TONOPORT V (firmware 2.1) do and what is it used for?","Question",{"text":63,"@type":64},"TONOPORT V is a small-size, patient-borne blood pressure monitor for ambulatory, non-invasive blood pressure measurement. It records blood pressure at selectable intervals for up to 30 hours and saves the results using selectable measurement protocols.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Who can TONOPORT V be used with, and who is it not suitable for?",{"text":68,"@type":64},"If the blood pressure cuffs listed in the Order Information fit the patient, TONOPORT V can be used on adults, children, and small children. It is not suitable for neonates and not suitable for intensive-care medicine.",{"name":70,"@type":61,"acceptedAnswer":71},"Which software systems can TONOPORT V work with?",{"text":72,"@type":64},"TONOPORT V can be used with CASE™ (version 5.15 or later) and/or the included analysis program CardioSoft (version 4.14 or later). If the USB port is used (CardioSoft only), additional requirements apply as described in the manual.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},641588,1792730146,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":108,"slug":109},7,40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":107,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":4},1099523885074,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","GE Healthcare  \nTONOPORT V  \nAmbulatory Blood Pressure System Firmware Version 2.1  \nOperator’s Manual  \n2001589-085 ENG Revision F  \nNote  \nThe information in this manual only applies to TONOPORT V, firmware version 2.1. It does not apply to earlier firmware versions.  \nDue to continuing product innovation, specifications in this manual are subject to change without notice.  \nCASE™ is a trademark owned by GE Medical Systems Information Technologies GmbH, a General Electric Company going to market as GE Healthcare.  \n© 2009–2016 General Electric Company. All rights reserved.  \n2 TONOPORT V 2001589-085 Revision F  \n1 Application, Safety Information 6  \n2 Controls and Indicators 10  \n3 Setup 12  \n4 Application 17  \n5 Data Output 21  \n6 Error Codes 22  \n7 Software Installation 23  \n8 Cleaning, Maintenance, Disposal 25  \n9 Technical Specifications 27  \n10 Order Information 28  \n11 Appendix-Electromagnetic Compatibility (EMC) 29  \nRevision History  \nThis manual is subject to the GE Healthcare change order service. The revision code, a letter that follows the document part number, changes with every update of the manual.  \nPart No./Revision Date Comment  \n2001589-085 Revision A 2009-05 Initial release  \n2001589-085 Revision B 2010-04 General Information: modifications in 3rd  \nparagraph  \nSection 1.3: additional information concerning the ingress of liquids  \nChapter 2: four symbols added  \nChapter 3: additional information concerning alternative charger  \n2001589-085 Revision C 2011-10-31 CardioSys was removed globally  \nChapters 1.1, 5 and 7: interface restrictions for CASE/CardioSoft were added  \nChapter 2: relevant battery charger symbols were added  \nChapter 7: CardioSoft version 6.7 for Windows 7 and reference to the “CASE-CS” folder were added Chapter 9: measuring range for mean pressure was corrected to '50 to 250 mmHg'  \n2001589-085 Revision D 2014-01-31 Changes on pages 4, 5, 11, 12, 23, and 24.  \n2001589-085 Revision E 2015-05-07 Changes on pages 8, 17, and 27.  \n2001589-085 Revision F 2016-07-12 Changes on pages 4, 11, and 28.  \n2001589-085 Revision F TONOPORT V 3  \nGeneral Information  \n􀁺 The product TONOPORT V bears the CE marking CE-0482 (notified body MEDCERT GmbH) indicating its compliance with the provisions of the Council Directive 93/42/EEC about medical devices (including amendment 2007/47/EC) and fulfills the essential requirements of Annex I of this directive. It has an internal power source and is an MDD class IIa device. The device fulfills the requirements of the Directive 2011/65/EU of the European Parliament and of the Council.  \n􀁺 It has a type BF applied part.  \n􀁺 The product fulfills the requirements of the standard EN/IEC 60601-1 \"Medical Electrical Equipment, Part  \n1: General Requirements for Basic Safety and Essential Performance\" as well as the electromagnetic immunity requirements of the standard EN/IEC 60601-1-2 \"Medical electrical equipment–Collateral standard: Electromagnetic compatibility – Requirements and tests\" and applicable amendments.  \n􀁺 The radio-interference emitted by this product is within the limits specified in CISPR11/EN 55011, class B.  \n􀁺 The CE marking covers only the accessories listed in the \"Order Information\" chapter.  \n􀁺 This manual is an integral part of the equipment. It should be available to the equipment operator at all times. Close observance of the information given in the manual is a prerequisite for proper equipment performance and correct operation and ensures patient and operator safety. Please note that information pertinent to several chapters is given only once. Therefore, carefully read the manual once in its entirety.  \n􀁺 The symbol  means: Consult accompanying documents. It indicates points which are of particular importance in the operation of the equipment.  \n􀁺 This manual reflects the equipment specifications and applicable safety standards valid at the time of printing. All rights are reserved for devices, circuits, techniques, software programs, and","cbCaiv5FXKaxpKwh","https://ap.wps.com/l/cbCaiv5FXKaxpKwh","pdf",797376,38,"English","# 1 Application, Safety Information\n## 1.1 Application Intended Use\n# 2 Controls and Indicators\n# 3 Setup\n# 4 Application\n# 5 Data Output\n# 6 Error Codes\n# 7 Software Installation\n# 8 Cleaning, Maintenance, Disposal\n# 9 Technical Specifications\n# 10 Order Information\n# 11 Appendix-Electromagnetic Compatibility (EMC)\n# Revision History","[{\"question\":\"What does TONOPORT V (firmware 2.1) do and what is it used for?\",\"answer\":\"TONOPORT V is a small-size, patient-borne blood pressure monitor for ambulatory, non-invasive blood pressure measurement. It records blood pressure at selectable intervals for up to 30 hours and saves the results using selectable measurement protocols.\"},{\"question\":\"Who can TONOPORT V be used with, and who is it not suitable for?\",\"answer\":\"If the blood pressure cuffs listed in the Order Information fit the patient, TONOPORT V can be used on adults, children, and small children. It is not suitable for neonates and not suitable for intensive-care medicine.\"},{\"question\":\"Which software systems can TONOPORT V work with?\",\"answer\":\"TONOPORT V can be used with CASE™ (version 5.15 or later) and/or the included analysis program CardioSoft (version 4.14 or later). If the USB port is used (CardioSoft only), additional requirements apply as described in the manual.\"}]","TONOPORT V - Firmware Version 2.1 - Operator’s Manual | PDF",1792715090,96]