[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-672956-105":59,"doc-detail-672956-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","tm11e-tower-runtime-selection-guide-atn1209-9ah-eod-165v-25c","TM11E Tower Runtime Selection Guide - ATN1209 9Ah EOD 1.65V 25°C","","TM11E Tower Runtime Selection Guide provides load-dependent runtime selection data for UPS configurations. It lists project references and battery/runtime parameters, including TM11E tower models with different block counts, PF 0.9 and efficiency values (η around 90–93.5%). Tables map load levels (50% through 100% output power) to runtime minutes for multiple configurations across 1 kVA to 10 kVA ranges, marking cases under 5 minutes with an asterisk and using specified battery and temperature conditions.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/tm11e-tower-runtime-selection-guide-atn1209-9ah-eod-165v-25c/672956/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/tm11e-tower-runtime-selection-guide-atn1209-9ah-eod-165v-25c/672956.png","ImageObject",300,407,{"name":92,"@type":93},"Tirek","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-02",true,{"@type":101,"interactionType":102,"userInteractionCount":8},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What information do the runtime tables provide for TM11E Tower configurations?","Question",{"text":111,"@type":112},"The tables relate each TM11E Tower project configuration to runtime (minutes) at specific load levels from 50% to 100%, under stated conditions like temperature and EOD.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"How are load levels shown in the guide?",{"text":116,"@type":112},"Load levels are expressed as percentages (50%, 60%, 70%, 80%, 90%, 100%) and correspond to the listed power values (e.g., 450W to 900W in the 1 kVA section).",{"name":118,"@type":109,"acceptedAnswer":119},"What does the asterisk (*) indicate in the runtime results?",{"text":120,"@type":112},"The guide notes that asterisk entries correspond to runtimes under 5 minutes, used in several high-load rows.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},672956,1793615754,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":81},5909896572756,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","TM11E Tower Runtime Selection Guide  \n1-10 kVA · TM11E · Tower · W/Block · ATN1209 9Ah · EOD 1. 65V · 25°C · ±10% · minutes at load · *=under 5 min  \n1 kVA · TM11E Tower · PF 0.9 · η 90%  \n\n| Configuration (project reference) | Blk | 50%\u003Cbr>450W | 60%\u003Cbr>540W | 70%\u003Cbr>630W | 80%\u003Cbr>720W | 90%\u003Cbr>810W | 100%\u003Cbr>900W |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| TM11E-1kVA-2X9 | 2 | 9.2 | 6.6 | 5.7 | 4.7* | 4.1* | 3.7* |\n| TM11E-1kVA-3X9 | 3 | 17 | 14 | 10 | 8.2 | 6.6 | 5.9 |\n| TM11E-1kVA-36S + 1x TC06036C-B | 6 | 41 | 33 | 27 | 23 | 20 | 17 |\n| TM11E-1kVA-3X9 + 1x TC06036C-B | 9 | 70 | 60 | 45 | 38 | 33 | 29 |\n| TM11E-1kVA-36S + 2x TC06036C-B | 12 | 103 | 80 | 67 | 60 | 48 | 41 |\n| TM11E-1kVA-3X9 + 2x TC06036C-B\u003Cbr>2 kVA · TM11E Tower · PF 0.9 · η 91% | 15 | 141 | 110 | 87 | 73 | 66 | 60 |\n| Configuration (project reference) | Blk | 50%\u003Cbr>900W | 60%\u003Cbr>1080W | 70%\u003Cbr>1260W | 80%\u003Cbr>1440W | 90%\u003Cbr>1620W | 100%\u003Cbr>1800W |\n| TM11E-2kVA-4X9 | 4 | 9.3 | 6.8 | 5.8 | 4.7* | 4.2* | 3.8* |\n| TM11E-2kVA-48S + 1x TC08048C-B | 8 | 25 | 20 | 17 | 14 | 11 | 9.3 |\n| TM11E-2kVA-4X9 + 1x TC08048C-B | 12 | 42 | 33 | 28 | 23 | 20 | 17 |\n| 3 kVA · TM11E Tower · PF 0.9 · η 92% |  |  |  |  |  |  |  |\n| Configuration (project reference) | Blk | 50%\u003Cbr>1350W | 60%\u003Cbr>1620W | 70%\u003Cbr>1890W | 80%\u003Cbr>2160W | 90%\u003Cbr>2430W | 100%\u003Cbr>2700W |\n| TM11E-3kVA-6X9 | 6 | 9.5 | 6.9 | 5.8 | 4.8* | 4.2* | 3.8* |\n| TM11E-3kVA-72S + 1x TC12072C-B | 12 | 26 | 20 | 17 | 14 | 12 | 9.5 |\n| TM11E-3kVA-6X9 + 1x TC12072C-B | 18 | 42 | 34 | 28 | 23 | 20 | 18 |\n| TM11E-3kVA-72S + 2x TC12072C-B | 24 | 65 | 51 | 40 | 34 | 29 | 26 |\n| TM11E-3kVA-6X9 + 2x TC12072C-B | 30 | 82 | 67 | 57 | 45 | 39 | 34 |\n| TM11E-3kVA-6X9 + 3x TC12072C-B\u003Cbr>6 kVA · TM11E Tower · PF 0.9 · η 93.5% | 42 | 133 | 102 | 82 | 70 | 63 | 55 |\n| Configuration (project reference) | Blk | 50%\u003Cbr>2700W | 60%\u003Cbr>3240W | 70%\u003Cbr>3780W | 80%\u003Cbr>4320W | 90%\u003Cbr>4860W | 100%\u003Cbr>5400W |\n| TM11E-6kVA-16X9 | 16 | 16 | 12 | 9.0 | 7.1 | 5.9 | 5.3 |\n| TM11E-6kVA-20X9 | 20 | 21 | 17 | 14 | 11 | 8.5 | 7.1 |\n| TM11E-6kVA-S + 1x TC40120N-B | 40 | 52 | 39 | 33 | 27 | 24 | 21 |\n| TM11E-6kVA-20X9 + 1x TC40120N-B | 60 | 84 | 68 | 59 | 46 | 39 | 35 |\n| TM11E-6kVA-S + 2x TC40120N-B | 80 | 128 | 96 | 78 | 68 | 62 | 52 |\n| TM11E-6kVA-20X9 + 2x TC40120N-B | 100 | 169 | 134 | 108 | 88 | 76 | 68 |\n| TM11E-6kVA-S + 3x TC40120N-B | 120 | 215 | 169 | 139 | 117 | 96 | 84 |\n| 10 kVA · TM11E Tower · PF 0.9 · η 93.5% |  |  |  |  |  |  |  |\n| Configuration (project reference) | Blk | 50%\u003Cbr>4500W | 60%\u003Cbr>5400W | 70%\u003Cbr>6300W | 80%\u003Cbr>7200W | 90%\u003Cbr>8100W | 100%\u003Cbr>9000W |\n| TM11E-10kVA-20X9 | 20 | 9.8 | 7.1 | 5.9 | 4.8* | 4.3* | 3.9* |\n| TM11E-10kVA-S + 1x TC40120N-B | 40 | 26 | 21 | 17 | 15 | 12 | 9.8 |\n| TM11E-10kVA-20X9 + 1x TC40120N-B | 60 | 43 | 35 | 29 | 24 | 21 | 18 |\n| TM11E-10kVA-S + 2x TC40120N-B | 80 | 66 | 52 | 41 | 35 | 30 | 26 |\n| TM11E-10kVA-20X9 + 2x TC40120N-B | 100 | 84 | 68 | 59 | 46 | 39 | 35 |\n| TM11E-10kVA-S + 3x TC40120N-B | 120 | 109 | 84 | 70 | 62 | 52 | 43 |\n| TM11E-10kVA-20X9 + 3x TC40120N-B | 140 | 136 | 104 | 84 | 71 | 64 | 57 |\n\nATENCO Power Tech · [atenco.com.tw](atenco.com.tw) · 05 Oct 2026","cbCaiexAalpHi5YQ","https://ap.wps.com/l/cbCaiexAalpHi5YQ","pdf",90233,"English","# Runtime selection tables\n## 1 kVA configurations\n## 2 kVA configurations\n## 3 kVA configurations\n## 6 kVA configurations\n## 10 kVA configurations","[{\"question\":\"What information do the runtime tables provide for TM11E Tower configurations?\",\"answer\":\"The tables relate each TM11E Tower project configuration to runtime (minutes) at specific load levels from 50% to 100%, under stated conditions like temperature and EOD.\"},{\"question\":\"How are load levels shown in the guide?\",\"answer\":\"Load levels are expressed as percentages (50%, 60%, 70%, 80%, 90%, 100%) and correspond to the listed power values (e.g., 450W to 900W in the 1 kVA section).\"},{\"question\":\"What does the asterisk (*) indicate in the runtime results?\",\"answer\":\"The guide notes that asterisk entries correspond to runtimes under 5 minutes, used in several high-load rows.\"}]","TM11E Tower Runtime Selection Guide - ATN1209 9Ah EOD 1.65V 25°C | PDF"]