[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-detail-398214-en":59,"doc-seo-398214-105":93},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":5,"data":60},{"doc_id":61,"user_id":62,"nickname":63,"user_avatar":64,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":66,"doc_content":67,"file_id":68,"file_url":69,"file_type":70,"file_size":71,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":72,"language":73,"language_code":74,"site_id":75,"html_lang":74,"table_of_contents":76,"faqs":77,"seo_title":78,"seo_description":66,"update_tm":79,"read_time":39,"preview_page_count":72,"preview_urls":80},398214,7421720224475,"Mary Man","https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","TITLE PLATFORM HEIGHT-EXEMPTION TRAINS OUTSIDE LOC&PAS ORIGINATOR SUBJECT RELATED TO NOBO ARSENAL RACE GMBH - Commission Regulation (EU) No 1299/2014/EU - Amendment Record, Description and Background Explanation","Clarification is requested on how point [4.2.9.2](4.2.9.2)(3) in the annex of TSI INF (EU) No 1299/2014 applies, particularly for platforms where trains outside the LOC&PAS TSI are intended to stop. The text defines nominal platform heights of 550 mm and 760 mm, lists deviation and exemption options, and highlights risk of misinterpreting exemption [f] when older rolling stock still stops at renewed platforms. A suggested resolution is to delete exemption [4.2.9.2](3), with ERA identified to respond and a disclaimer that ERA always supersedes NB-Rail’s suggested solution.","| | \u003Cbr>|  |\n| --- | --- | --- |\n| \u003Cbr>| TITLE PLATFORM HEIGHT-EXEMPTION TRAINS OUTSIDE LOC&PAS ORIGINATOR SUBJECT RELATED TO NOBO ARSENAL RACE GMBH - Commission Regulation (EU) No 1299/2014/EUTSI INF\u003Cbr>- Amendment of Commission Regulation (EU) No 2019/776 AMENDMENT RECORD: DESCRIPTION AND BACKGROUND EXPLANATION The aim of this question is to clarify the application and consequences of point [4.2.9.2](4.2.9.2)[ ](4.2.9.2)(3) in the annex of TSI INF (EU) No 1299/2014 . As the sentence is being kept without change in the upcoming amendment of TSI INF 2014 (refer to point [4.2.10.2](4.2.10.2). (3)), some questions have to be clarified.\u003Cbr>The nominal platform height is defined in the annex of TSI INF in point [4.2.9.2](4.2.9.2) (1) . Two nominal platform heights (550 mm and 760 mm ) above the running surface shall be used.\u003Cbr>Within TSI INF several provisions for deviating from the nominal platform height are given , such as:\u003Cbr>a. Member states related specific cases detailed in point 7.7 of annex of TSI INF.\u003Cbr>b. Point 7.4. (a) For existing platforms it shall be allowed to apply other nominal platform heights for consistency with a particular upgrade or renewal programme of a line or a section of a line.\u003Cbr>c. Point 7.4. (b) For existing platforms it shall be allowed to apply other nominal platform heights, if the work requires structural alterations to any load bearing element.\u003Cbr>d. Point 4.2.9. (1) Nominal platform height requirement is only applicable for platforms where trains are intended to stop in normal service. (“Normal service”= The railway operating to a planned timetable service) .\u003Cbr>e. Point 4.2.9. (2) It is permissible to design platforms required for the current service requirement provided provision is made for the reasonably foreseeable future service requirements. When specifying the interfaces with trains intended to stop at the platform, consideration shall be given to both the current service requirements and the reasonably foreseeable service requirements at least 10 years following the bringing into service of the platform.\u003Cbr>f. Point [4.2.9.2](4.2.9.2). (3) For platforms where trains, which are outside the scope of the LOC&PAS TSI, are intended to stop, different provisions for the nominal platform height might apply.\u003Cbr>Exemption cases a. to e. detail several options where a newly built or upgraded platform does not need to meet the nominal platform height requirement. All these exemption | |\n\n| | \u003Cbr>|  |\n| --- | --- | --- |\n| \u003Cbr>| cases detail clear rules and constraints or refer to a “fixed” constraint like needed alteration to any load bearing element which is unlikely to change over the time. Exemption case f. , i.e. [4.2.9.2](4.2.9.2). (3) however can be easily misinterpreted in such a way that where older rolling stock is still intended to stop , different platform height might be realized without any further requirements such as it must still be in line with a particular renewal programme of a section of a line , etc. Older rolling stock in this context means wagons that had been put into service before TSI LOC&PAS came into force.\u003Cbr>Example:\u003Cbr>A rolling stock running on a specific line was put into operation in May 2009 before the TSI LOC&PAS for conventional railways came into force. Considering a service life of approximately 30 years it remains in service another 20 years.\u003Cbr>In June 2019 on this specific line a platform is being renewed, expected service time another 60 years. For some reasons (which are none of the specified exemptions [a. to](a. to)[e](e). ) it is intended to build the platform at a different nominal height. To still gain an ECcertificate of verification, exemption [f. is](f. is) claimed as being applicable since on this line rolling stock outside of LOC&PAS is intended to stop. Note: “intended to stop” does not necessarily require only rolling stock outside of LOC&PAS stopping at this platform. Legally, an EC-certificate of verification must be granted even witho","cbCaia4apeTq3HFA","https://ap.wps.com/l/cbCaia4apeTq3HFA","pdf",537881,3,"English","en",105,"# Clarification objective\n## Nominal platform height requirements\n## Deviation and exemption cases\n# Misinterpretation risk and example scenario\n## EC verification and boarding aids\n# Suggested resolution and responding organisations","[{\"question\":\"What is the purpose of the question clarification regarding TSI INF platform heights?\",\"answer\":\"To clarify the application and consequences of point [4.2.9.2](4.2.9.2)(3) in the annex of TSI INF (EU) No 1299/2014, including how exemption interpretation affects platform height decisions.\"},{\"question\":\"How are nominal platform heights defined and which values must be used?\",\"answer\":\"The annex defines the nominal platform height in point [4.2.9.2](1), and two nominal platform heights of 550 mm and 760 mm above the running surface are to be used.\"},{\"question\":\"Why can exemption case f be misinterpreted, and what does the text warn about?\",\"answer\":\"It can be misread to justify different platform height for older rolling stock without meeting related constraints such as alignment with a renewal programme, even though older stock had been put into service before TSI LOC\\u0026PAS took effect.\"},{\"question\":\"What resolution is suggested and who is requested to respond?\",\"answer\":\"The solution suggested is to erase exemption [4.2.9.2](3). ERA is identified as the organisation requested to respond, with a disclaimer that ERA always supersedes NB-Rail’s suggested solution.\"}]","TITLE PLATFORM HEIGHT-EXEMPTION TRAINS OUTSIDE LOC&PAS ORIGINATOR SUBJECT RELATED TO NOBO ARSENAL RACE GMBH - Commission Regulation (EU) No 1299/2014/EU - Amendment Record, Description and Background Explanation | PDF",1790473630,[81,85,89],{"page_no":8,"url":82,"width":83,"height":84},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/9011d91cb5455e7e086e1a4864c3ce3e.webp",983,1390,{"page_no":14,"url":86,"width":87,"height":88},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/351f6bbf2223ae4a3988635621522531.webp",982,1388,{"page_no":72,"url":90,"width":91,"height":92},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/8746f06ae7ab6384f4da82cfee8c8195.webp",981,1387,{"code":4,"msg":94,"data":95},"ok",{"site_id":75,"language":74,"slug":96,"title":65,"keywords":97,"description":66,"schema_data":98,"social_meta":155,"head_meta":157,"extra_data":159,"updated_unix":160},"title-platform-height-exemption-trains-outside-locpas-originator-subject-related-to-nobo-arsenal-race-gmbh-commission-regulation-eu-no-12992014eu-amendment-record-description-and-background-explanation","",{"@graph":99,"@context":154},[100,113,133],{"@type":101,"itemListElement":102},"BreadcrumbList",[103,107,109,111],{"item":104,"name":105,"@type":106,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":108,"name":9,"@type":106,"position":14},"https://docshare.wps.com/document/",{"item":110,"name":40,"@type":106,"position":72},"https://docshare.wps.com/document/research-report/",{"item":112,"name":65,"@type":106,"position":19},"https://docshare.wps.com/document/title-platform-height-exemption-trains-outside-locpas-originator-subject-related-to-nobo-arsenal-race-gmbh-commission-regulation-eu-no-12992014eu-amendment-record-description-and-background-explanation/398214/",{"url":112,"name":65,"@type":114,"image":115,"author":120,"headline":65,"publisher":122,"fileFormat":125,"inLanguage":74,"description":66,"dateModified":126,"datePublished":127,"encodingFormat":125,"isAccessibleForFree":128,"interactionStatistic":129},"DigitalDocument",{"url":116,"@type":117,"width":118,"height":119},"https://docshare.wps.com/thumbnails/title-platform-height-exemption-trains-outside-locpas-originator-subject-related-to-nobo-arsenal-race-gmbh-commission-regulation-eu-no-12992014eu-amendment-record-description-and-background-explanation/398214.png","ImageObject",300,407,{"name":63,"@type":121},"Person",{"url":104,"name":123,"@type":124},"DocShare","Organization","application/pdf","2026-11-05","2026-09-27",true,{"@type":130,"interactionType":131,"userInteractionCount":39},"InteractionCounter",{"@type":132},"ViewAction",{"@type":134,"mainEntity":135},"FAQPage",[136,142,146,150],{"name":137,"@type":138,"acceptedAnswer":139},"What is the purpose of the question clarification regarding TSI INF platform heights?","Question",{"text":140,"@type":141},"To clarify the application and consequences of point [4.2.9.2](4.2.9.2)(3) in the annex of TSI INF (EU) No 1299/2014, including how exemption interpretation affects platform height decisions.","Answer",{"name":143,"@type":138,"acceptedAnswer":144},"How are nominal platform heights defined and which values must be used?",{"text":145,"@type":141},"The annex defines the nominal platform height in point [4.2.9.2](1), and two nominal platform heights of 550 mm and 760 mm above the running surface are to be used.",{"name":147,"@type":138,"acceptedAnswer":148},"Why can exemption case f be misinterpreted, and what does the text warn about?",{"text":149,"@type":141},"It can be misread to justify different platform height for older rolling stock without meeting related constraints such as alignment with a renewal programme, even though older stock had been put into service before TSI LOC&PAS took effect.",{"name":151,"@type":138,"acceptedAnswer":152},"What resolution is suggested and who is requested to respond?",{"text":153,"@type":141},"The solution suggested is to erase exemption [4.2.9.2](3). ERA is identified as the organisation requested to respond, with a disclaimer that ERA always supersedes NB-Rail’s suggested solution.","https://schema.org",{"og:url":112,"og:type":156,"og:title":65,"og:site_name":123,"og:description":66},"article",{"robots":158,"canonical":112},"index,follow",{"doc_id":61,"site_id":75},1791254588]