[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663272-105":59,"doc-detail-663272-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","titan-application-diagrams-hardware-use-requirements","TITAN - Application Diagrams - Hardware Use Requirements","","Application diagrams define the maximum sash dimensions for TITAN window hardware under specific element weights, focusing on durability and also indicating loadbearing capacity where an additional load applies per EN 14608 (Figure A.1). The document explains that application diagram values are derived from assembly instructions and component catalog data, and establishes rules for component combinations, applicable window element configurations, and glass-size reduction (CG) and profile weight (PG) limits. It also provides calculation methods for element weight (GG) based on glass thickness and glass pane mass.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/titan-application-diagrams-hardware-use-requirements/663272/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/titan-application-diagrams-hardware-use-requirements/663272.png","ImageObject",300,407,{"name":92,"@type":93},"dbqoiu","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are application diagrams used for in relation to window hardware?","Question",{"text":112,"@type":113},"They show the maximum sash dimensions at a specific element weight for which a hardware piece may be used. They focus on durability and may include loadbearing capacity when an additional load applies per EN 14608 (Figure A.1).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which documents govern if application diagram values differ from other product data?",{"text":117,"@type":113},"The assembly instructions always apply if values differ, while the component catalogue provides an alternative data reference.",{"name":119,"@type":110,"acceptedAnswer":120},"How is specific element weight (GG) determined for glazing?",{"text":121,"@type":113},"GG is calculated using the example formula: GG ≈ 2.5 kg/m²·mm × total glass thickness, where total glass thickness equals the sum of the pane thicknesses.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663272,1793226158,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":41},3985747862462,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","Intended use  \nAPPLICATION DIAGRAMS  \nIntended use.  \nWINDOW HARDWARE  \nDOOR HARDWARE  \n~~SLIDING DOOR HARDWARE ~~VENTILATION TECHNOLOGY ~~BUILDING TECHNOLOGY~~  \nWINDOW HARDWARE  \nTITAN  \nIntended use  \nValid for all application diagrams  \nFunction  \nApplication diagrams show the maximum sash dimensions at a specific element weight for which a piece of hardware may be used. Application diagrams focus exclusively on the property of durability and may also provide information on the loadbearing capacity of the hardware when subjected to an additional load according to EN 14608 (Figure A. 1) .  \nBasic principles  \nApplication diagrams are produced on the basis of the ift guideline \"Preparation of application diagrams for turn and tilt-turn hardware\". The guideline provides more information on using application diagrams and can be downloaded at  \n[www.anwendungsdiagramme.de](www.anwendungsdiagramme.de).  \nAbbreviations and icons  \nThe following abbreviations and icons are used in this document and in all other application diagrams.  \nAbbreviations  \nCG  \nFB  \nFFH  \nFFH BS  \nFH AB  \nPG  \nReduction in glass size [mm] Sash width [mm]  \nSash rebate height [mm]  \nSash rebate height on the hinge side [mm] Sash height up to the start of the arched head [mm]  \nProfile weight [kg/m]  \nGG  \nFFB  \nFFH AB  \nFH  \nFH BS  \nQB/H  \nSpecific element weight [kg/m2] Sash rebate width [mm]  \nSash rebate height up to the start of the arched head [mm]  \nSash height [mm]  \nSash height on the hinge side [mm] Max. width-to-height ratio (= FFB/FFH)  \nIcons  \nTilt-turn window element  \nTilt window element  \nRounded head window element  \nTriangular window element  \nFrame material: timber  \nFrame material: light metal  \nTurn window element  \nArched head window element  \nAngled window element  \nMaximum permissible sash weight  \nFrame material: PVC  \nPage 2/11 03.2014  H58 .AWD_BG_EN  \nIntended use  \nValid for all application diagrams  \nTITAN  \nRequirements for use  \nPlease note and comply with the following points at all times when using application diagrams and hardware:  \n• The application ranges for the hardware are derived from the size specifications in the assembly instructions/component catalogue and from those in the relevant application diagram. If the values differ, the data in the assembly instructions always applies, with the data in the component catalogue providing an alternative.  \n• If a combination of components with different load-bearing capacities is being used, the application diagram for the component with the lowest load-bearing capacity is always the one that applies.  \n• Guidelines/notes on the product and on liability (VHBH directive as well as the other applicable documents listed here in directive can be downloaded [at](at www.beschlagindustrie.de/ggsb/richtlinien.asp)[ www.beschlagindustrie.de/ggsb/richtlinien.asp](at www.beschlagindustrie.de/ggsb/richtlinien.asp)) .  \n• Specifications from the profile manufacturers/system owners (e.g. for window systems with frames made of timber, PVC, light metal or combinations of materials) or DIN 68121 \"Timber profiles for windows and French windows\" – with particular regard to potential restrictions for the sash dimensions and sash weight.  \n• Guidelines and, where applicable, application diagrams in the product documentation supplied by the relevant glass or infill panel manufacturer.  \n• In accordance with the application diagrams, the hardware is to be used exclusively for window elements which are installed vertically in walls in permanent structures, unless otherwise indicated.  \n• The application diagrams apply exclusively to hardware used in window elements which open inwards, unless otherwise indicated.  \n• In accordance with the relevant application diagrams, the hardware is to be used exclusively for window elements in which the reduction in glass size (CG) is greater than or equal to the specified value, and the profile weight (PG) is less than or equal to the specified value.  \n• ","cbCaiaoltDsvMhza","https://ap.wps.com/l/cbCaiaoltDsvMhza","pdf",744802,12,"English","# Intended use\n## Application diagrams and durability scope\n## Basic principles and source guideline\n## Abbreviations and icons\n# Requirements for use\n## Limits, compliance, and liability\n# Reduction in glass size (CG)\n# Profile weight (PG)\n# Element weight (GG)\n## Determining GG for glazing\n## Example calculations","[{\"question\":\"What are application diagrams used for in relation to window hardware?\",\"answer\":\"They show the maximum sash dimensions at a specific element weight for which a hardware piece may be used. They focus on durability and may include loadbearing capacity when an additional load applies per EN 14608 (Figure A.1).\"},{\"question\":\"Which documents govern if application diagram values differ from other product data?\",\"answer\":\"The assembly instructions always apply if values differ, while the component catalogue provides an alternative data reference.\"},{\"question\":\"How is specific element weight (GG) determined for glazing?\",\"answer\":\"GG is calculated using the example formula: GG ≈ 2.5 kg/m²·mm × total glass thickness, where total glass thickness equals the sum of the pane thicknesses.\"}]","TITAN - Application Diagrams - Hardware Use Requirements | PDF"]