[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664800-105":59,"doc-detail-664800-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","timber-framed-construction-for-townhouse-buildings-class-1a-design-and-construction-guide-for-bca-compliant-sound-and-fire-rated-construction","Timber-framed Construction for Townhouse Buildings Class 1a - Design and construction guide for BCA compliant sound and fire-rated construction","","Timber-framed Construction for Townhouse Buildings Class 1a provides expert guidance for designing and constructing BCA-compliant sound and fire-rated townhouse buildings using timber-framed systems. The guide covers high-level design issues, defining sound requirements using deemed-to-satisfy provisions, improving sound performance through design checks and construction strategies, and establishing fire-design requirements and fire resistance levels for wall elements. It also supports selection of appropriate timber construction systems by outlining principles for achieving required fire resistance and sound insulation.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/timber-framed-construction-for-townhouse-buildings-class-1a-design-and-construction-guide-for-bca-compliant-sound-and-fire-rated-construction/664800/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/timber-framed-construction-for-townhouse-buildings-class-1a-design-and-construction-guide-for-bca-compliant-sound-and-fire-rated-construction/664800.png","ImageObject",300,407,{"name":92,"@type":93},"Franzy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What does this guide focus on for Class 1a townhouse buildings?","Question",{"text":112,"@type":113},"The guide focuses on designing and constructing BCA-compliant sound and fire-rated construction for timber-framed townhouse buildings.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the guide define sound-design requirements?",{"text":117,"@type":113},"It explains how to use the deemed-to-satisfy provisions for sound design, determine sound-insulation requirements for separating walls, and address services relevant to timber-framed construction.",{"name":119,"@type":110,"acceptedAnswer":120},"How are fire-design requirements established in the guide?",{"text":121,"@type":113},"It outlines how to utilise the deemed-to-satisfy provisions for fire design and specifies fire resistance levels for wall elements.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},664800,1793273174,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},2336478945519,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","01   \nThis guide was  \nrevised in March 2023  \nPlease check [woodsolutions.com.au/publications](woodsolutions.com.au/publications)[ ](woodsolutions.com.au/publications)to ensure you have the latest edition  \nTimber-framed Construction for Townhouse Buildings Class 1a  \nDesign and construction guide for BCA compliant sound and fire-rated construction  \nTechnical Design Guide issued by Forest and Wood Products Australia  \nWoodSolutions Technical Design Guides  \nA growing suite of information, technical and training resources, the Design Guides have been created to support the use of wood in the design and construction of the built environment.  \nEach title has been written by experts in the field and is the accumulated result of years of experience in working with wood and wood products.  \nSome of the popular topics covered by the Technical Design Guides include:  \n• Timber-framed construction  \n• Building with timber in bushfire-prone areas  \n• Designing for durability  \n• Timber finishes  \n• Stairs, balustrades and handrails  \n• Timber flooring and decking  \n• Timber windows and doors  \n• Fire compliance  \n• Acoustics  \n• Thermal performance  \nMore WoodSolutions Resources  \nThe WoodSolutions website provides a comprehensive range of resources for architects, building designers, engineers and other design and construction professionals.  \nTo discover more, please visit [www.woodsolutions.com.au](www.woodsolutions.com.au)[ ](www.woodsolutions.com.au)[The website for wood](The website for wood).  \nWoodSolutions is an industry initiative designed to provide independent, non-proprietary information about timber and wood products to professionals and companies involved in building design and construction.  \nWoodSolutions is resourced by Forest and Wood Products Australia (FWPA) . It is a collaborative effort between FWPA members and levy payers, supported by industry peak bodies and technical associations.  \nThis work is supported by funding provided to FWPA by the Commonwealth Government.  \nISBN 978-1-920883-78-2  \nResearcher:  \nTimber Development Association (NSW) Suite 604, 486 Pacific Highway St Leonards NSW 2065  \nPrinted: May 2010  \nRevised: May 2012, August 2012, September 2015, February 2021, March 2023  \n© 2023 Forest and Wood Products Australia Limited.  \nAll rights reserved.  \nThese materials are published under the brand WoodSolutions by FWPA.  \nIMPORTANT NOTICE  \nWhilst all care has been taken to ensure the accuracy of the information contained in this publication, Forest and Wood Products Australia Limited and WoodSolutions Australia and all persons associated with them (FWPA) as well as any other contributors make no representations or give any warranty regarding the use, suitability, validity, accuracy, completeness, currency or reliability of the information, including any opinion or advice, contained in this publication. To the maximum extent permitted by law, FWPA disclaims all warranties of any kind, whether express or implied, including but not limited to any warranty that the information is up-to-date, complete, true, legally compliant, accurate, non-misleading or suitable.  \nTo the maximum extent permitted by law, FWPA excludes all liability in contract, tort (including negligence), or otherwise for any injury, loss or damage whatsoever (whether direct, indirect, special or consequential) arising out of or in connection with use or reliance on this publication (and any information, opinions or advice therein) and whether caused by any errors, defects, omissions or misrepresentations in this publication. Individual requirements may vary from those discussed in this publication and you are advised to check with State authorities to ensure building compliance as well as make your own professional assessment of the relevant applicable laws and Standards.  \nThe work is copyright and protected under the terms of the Copyright Act 1968 (Cwth) . All material may be reproduced in whole or in part, provided that it is n","cbCaikmXmfl5sOl7","https://ap.wps.com/l/cbCaikmXmfl5sOl7","pdf",6283026,48,"English","# Introduction\n# Step 1 – High-Level BCA Design Issues\n## 1.1 Determine the Class of Building\n## 1.2 BCA Compliance – Deemed to Satisfy Provisions or Alternative Solutions\n## 1.3 Fire and Sound Separation in Buildings\n# Step 2 – Define BCA Sound-Design Requirements\n## 2.1 Utilising the Deemed to Satisfy Provisions for Sound Design\n## 2.2 Determine Sound-Insulation Requirements In Separating Walls\n## 2.3 Treatment of Services Relevant to Timber-Framed Construction\n## 2.4 The Next Step\n# Step 3 – Improve and Upgrade Sound Performance\n## 3.1 Checking and Adjusting the Building Design to Reduce Sound Transmission\n## 3.2 Strategies for Improving Sound Performance in Construction\n## 3.3 The Next Step\n# Step 4 – Define Fire-Design Requirements\n## 4.1 Utilising the Deemed to Satisfy Provisions for Fire Design\n## 4.2 Fire Resistance Levels of Wall Elements\n## 4.3 The Next Step\n# Step 5 – Select Sound-and Fire-Rated Timber Construction Systems\n## 5.1 Principles for Achieving Fire Resistance Levels in Timber-Framed Construction\n## 5.2 Principles for Achieving Sound Insulation in Timber-Framed Construction","[{\"question\":\"What does this guide focus on for Class 1a townhouse buildings?\",\"answer\":\"The guide focuses on designing and constructing BCA-compliant sound and fire-rated construction for timber-framed townhouse buildings.\"},{\"question\":\"How does the guide define sound-design requirements?\",\"answer\":\"It explains how to use the deemed-to-satisfy provisions for sound design, determine sound-insulation requirements for separating walls, and address services relevant to timber-framed construction.\"},{\"question\":\"How are fire-design requirements established in the guide?\",\"answer\":\"It outlines how to utilise the deemed-to-satisfy provisions for fire design and specifies fire resistance levels for wall elements.\"}]","Timber-framed Construction for Townhouse Buildings Class 1a - Design and construction guide for BCA compliant sound and fire-rated construction | PDF",121]