[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664797-105":59,"doc-detail-664797-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","timber-frame-standard-details-nailing-schedule-construction-guidance","Timber Frame Standard Details - Nailing Schedule - Construction guidance","","Indicative timber frame detail guidance covering how manufactured timber frame structures should be specifically designed and detailed for each project. The document instructs that construction must follow the provided drawings and construction details, coordinating with architects and engineers, and allows amendments to suit building regulations and practices. It outlines sectional contents for chimneys, soleplates, flooring, panel erection, party walls, roof setting out, services, and additional information, including detailed nailing schedules, fixing methods, and requirements for vapour barriers, insulation, firestops, and structural strutting.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/timber-frame-standard-details-nailing-schedule-construction-guidance/664797/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/timber-frame-standard-details-nailing-schedule-construction-guidance/664797.png","ImageObject",300,407,{"name":92,"@type":93},"Aran","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of these timber frame standard details?","Question",{"text":112,"@type":113},"The details provide indicative guidance for current timber frame practice. Any structure supplied is designed and detailed specifically for the project, and details must be followed with the relevant drawings.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How should timber frame construction be executed according to the document?",{"text":117,"@type":113},"Construction must be carried out in accordance with the drawings and construction details, and all details must be read with relevant architects’ and engineers’ details.",{"name":119,"@type":110,"acceptedAnswer":120},"What main items are included in the document’s content sections?",{"text":121,"@type":113},"Sections cover chimneys, nailing, soleplate, flooring, panel erection, party walls, roof setting out, services, and additional information, including related fixing and schedule details.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},664797,1793273161,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},137455076865,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","# Timber Frame Manufacturers\n\nSTANDARD TIMBER FRAME DETAILS  \nThe enclosed details are indicative of current practise of Firwood Timber Frame and areused as guidance only.  \nAny timber frame structure manufactured and supplied by Firwood Timber Frame will bedesigned specifically for the project and will be detailed accordingly.  \nConstruction of the timber frame must be carried out in accordance with drawings anddetails for construction.  \nAll details must be read in conjunction with all relevant Architects and engineers'details.  \nWe reserve the right to amend details to suit changes in building regulations and buildingpractices.  \nContents page  \n7.Chimneys  \n## 1.Nailing\n\n● Internal chimney  \nExternal chimney  \n## 2.Soleplate\n\n。  Intermediate chimney  \n● Fixing:external by shot firing  \n。Fixing:external with soleplate anchors  \n。Fixing:external soleplates with restraint straps  \n## 8.Services\n\n● Fixing:internal soleplates  \n。  Party wall electrics  \n。  Balanced flue  \n## 3.Flooring\n\n·  Concrete flue  \n● Joist fixing  \n。Soil &vent pipe detail  \n·Chipboard decking fixing  \n。Notching and holes injoists  \n。External wallfirst floor junction  \n。Floating floor  \n## 9.Additional information\n\n● Floating floor:installation details  \n● Vertical shrinkage  \n● Floating floor:internal door threshold detail  \n。Scaffolding requirements  \n● Floating floor:flat entrance door threshold detail  \n## 4.Panel erection\n\n● Panel fixing  \n● Breather paper  \n● Cavity barrier  \n● Cavity barrier:Compartment floors  \n## 5.Party walls\n\n●·Party wall:steps  \n● Party wall:Staggers  \n● Compartment walls:roof space  \n## 6.Roof setting out\n\n○ Standard eaves  \n● Standard verge  \n● Parapet verge  \nTimber Frame  \n● Parapet eaves  \nStandard details  \n## Nailing Schedule\n\nSoleplates  \n32x3.75mm dia rustproofed square twistedHilti NK 27 or 72 S12 or similar  \n## External &Internal panels\n\n50x3.0mm dia rustproofed plain head75x3.35mm dia rustproofed plain head  \n90x4mm dia rustproofed plain head  \n## Walls/miscellaneous\n\n75x3.35mm dia rustproofed plain head40x2.65mm dia stainless steel ringed shankGalvanized staplesStainless steel staples  \n## Floors\n\n90x4mm dia rustproofed plain head  \n75x3.35mm dia rustproofed plain head32x3.75mm dia rustproofed square twist60x3.35mm dia rustproofed ringed shank  \n2 per soleplate anchor600c/s or greater,soleplate &soleplate anchors  \nSheathing to panel  \nBottom rail of panel to soleplate @300c/s and staggeredAll panel to panel junctions @600c/sPlasterboard noggins  \n38x89 noggins to ceilings at head of parallel partitionsTee junction skew nail @600c/s  \nTimber firestop battens to timber frameLoose brick ties to external panelsPolythene vapour barrier to external panels60x65 mineral wool cavity barrier to external panels  \nJoist to header  \nStitching headers and joists to panelsSolid strutting to joistsHerring bone strutting to joistsJoists and trimmers to hangers  \nDecking to joists in accordance with manufactures recommen-dations Generally @150mm c/s  \nTimber Frame  \nStandard details  \n## Nailing Schedule\n\nRoof  \n65x3.35mm dia rustproofed plain head  \n75x3.35mm dia rustproofed plain head  \n90x4mm dia rustproofed plain head  \n65x3.35mm dia rustproofed lost head40x2.36mm dia rustproofed lost head32x3.75mm dia rustproofed square twisted  \n40x3.35mm dia rustproofed clout nails  \n## External joinery\n\n32x3.75mm dia rustproofed square twisted  \nVent to fascia  \nTiling battens and counter battens to raftersTilt ply to rafters  \nWind bracing to trusses and peak panelsPlasterboard noggins  \nEaves framing to rafters,external panels etc.Spandrel panels to external panels below38x89 ceiling batten to spandrel panel  \nBlockings to base of spandrel panel to take wind bracingDitto to flank wallsVerge sprocket to trussed raftersVerge sprocket to verge rafterTank stand material  \nFascias,bargeboards and any other exposed itemsSoffit ply to bearers/sprocketsTruss clips to trusses and wallplatesTruss hangers to trussesSarking felt to rafters  \nFrame ","cbCaiiFnbicwOVL1","https://ap.wps.com/l/cbCaiiFnbicwOVL1","pdf",8571854,38,"English","# Timber Frame Manufacturers\n## 1. Nailing\n## 2. Soleplate\n## 3. Flooring\n## 4. Panel erection\n## 5. Party walls\n## 6. Roof setting out\n## 7. Chimneys\n## 8. Services\n## 9. Additional information\n## Nailing Schedule","[{\"question\":\"What is the purpose of these timber frame standard details?\",\"answer\":\"The details provide indicative guidance for current timber frame practice. Any structure supplied is designed and detailed specifically for the project, and details must be followed with the relevant drawings.\"},{\"question\":\"How should timber frame construction be executed according to the document?\",\"answer\":\"Construction must be carried out in accordance with the drawings and construction details, and all details must be read with relevant architects’ and engineers’ details.\"},{\"question\":\"What main items are included in the document’s content sections?\",\"answer\":\"Sections cover chimneys, nailing, soleplate, flooring, panel erection, party walls, roof setting out, services, and additional information, including related fixing and schedule details.\"}]","Timber Frame Standard Details - Nailing Schedule - Construction guidance | PDF",96]