[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-335091-105":59,"doc-detail-335091-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","three-dimensional-trans-rectal-and-trans-abdominal-ultrasound-image-fusion-for-the-guidance-of-gynecologic-brachytherapy-procedures-a-proof-of-concept-study","Three-dimensional trans-rectal and trans-abdominal ultrasound image fusion for the guidance of gynecologic brachytherapy procedures - a proof of concept study","","Three-dimensional trans-abdominal and trans-rectal ultrasound image fusion is developed to support accurate guidance of gynecologic high dose-rate brachytherapy procedures. The workflow acquires, registers, and fuses 3D ultrasound images to visualize pelvic anatomy and applicators during insertion, validated using custom multi-modal pelvic phantoms and demonstrated in two patient procedures. Fused 3D ultrasound data are registered to MR and CT images, and accuracy is quantified using target registration error and fiducial localization error across modality combinations. Results show mean TRE of 4.01 ± 1.01 mm and mean FLE of 0.43 ± 0.24 mm, supporting further clinical studies using 3D ultrasound as an accessible alternative.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/three-dimensional-trans-rectal-and-trans-abdominal-ultrasound-image-fusion-for-the-guidance-of-gynecologic-brachytherapy-procedures-a-proof-of-concept-study/335091/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/three-dimensional-trans-rectal-and-trans-abdominal-ultrasound-image-fusion-for-the-guidance-of-gynecologic-brachytherapy-procedures-a-proof-of-concept-study/335091.png","ImageObject",300,407,{"name":92,"@type":93},"Oliver","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04","2026-09-21",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What problem does the study address in gynecologic brachytherapy guidance?","Question",{"text":112,"@type":113},"Accurate radiation delivery requires precise localization of intracavitary applicators at insertion. The study targets the need for reliable visualization and guidance during the procedure using 3D ultrasound fusion.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How was the proposed ultrasound fusion workflow validated?",{"text":117,"@type":113},"Validation used custom multi-modal pelvic phantoms and was demonstrated during two patient procedures. Fused ultrasound images were also registered to MR and CT for comparison.",{"name":119,"@type":110,"acceptedAnswer":120},"What accuracy metrics and results were reported?",{"text":121,"@type":113},"Accuracy was quantified using target registration error (TRE) and fiducial localization error (FLE). Across all modality registrations, TRE and FLE had mean ± standard deviation values of 4.01 ± 1.01 mm and 0.43 ± 0.24 mm, respectively.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},335091,1790261877,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":41,"preview_page_count":4},8796095461610,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nThree‑dimensional trans‑rectal and trans‑abdominal ultrasound image fusion for the guidance of gynecologic brachytherapy procedures: a proof of concept study  \nTiana Trumpour1,2*, Carla du Toit2, Alissa van Gaalen3, Claire K. S. Park4, Jessica R. Rodgers 5, Lucas C. Mendez6, Kathleen Surry1,6,7 & Aaron Fenster1,2  \nHigh dose‑rate brachytherapy is a treatment technique for gynecologic cancers where intracavitary applicators are placed within the patient’s pelvic cavity. To ensure accurate radiation delivery, localization of the applicator at the time of insertion is vital. This study proposes a novel method for acquiring, registering, and fusing three‑dimensional (3D) trans‑abdominal and 3D trans‑rectal ultrasound (US) images for visualization of the pelvic anatomy and applicators during gynecologic brachytherapy. The workflow was validated using custom multi‑modal pelvic phantoms and demonstrated during two patient procedures. Experiments were performed for three types of intracavitary applicators: ring‑and‑tandem, ring‑and‑tandem with interstitial needles, and tandem‑ and‑ovoids. Fused 3D US images were registered to magnetic resonance (MR) and computed tomography (CT) images for validation. The target registration error (TRE) and fiducial localization error (FLE) were calculated to quantify the accuracy of our fusion technique. For both phantom and patient images, TRE and FLE across all modality registrations (3D US versus MR or CT) resulted in mean ± standard deviation of 4.01 ± 1.01 mm and 0.43 ± 0.24 mm, respectively. This work indicates proof of concept for conducting further clinical studies leveraging 3D US imaging as an accurate, accessible alternative to advanced modalities for localizing brachytherapy applicators.  \nGynecologic cancers are some of the most frequently diagnosed cancers in women, accounting for 13.3% of cancer incidences in 20201. High dose-rate (HDR) brachytherapy is a common form of internal radiation therapy used during the treatment process of gynecologic cancers owing to the increased precision associated with the delivery of very high dose, short-range radiation to cervical and endometrial malignancies2,3. This method is known to reduce the risk of normal tissue toxicity while delivering therapeutic doses with curative intent, asthe radiation dose is conformal within the cancerous region thus sparing the surrounding healthy tissues from exposure to unnecessary radiation4. A wide range of applicator systems exist for delivering short-range radiation; however, intracavitary applicators such as Vienna/ring-and-tandem (with or without interstitial needles) or Fletcher/tandem-and-ovoids applicators are commonly used (Fig. 2)5–7. In treating cervical or endometrial cancers where the uterus remains intact, the applicator is positioned within the vagina, extending through the cervix and into the uterus. Interstitial needles may be added for additional targeting and are inserted through the patient’s perineum. Precise and accurate placement of the applicator and needles is vital for successful treatment, as well as the protection of the surrounding organs at risk (OARs), including the bladder and rectum8–10.  \n1Department of Medical Biophysics, Western University, London, Canada. 2Robarts Research Institute, London, Canada. 3Department of Physics and Astronomy, University of Waterloo, Waterloo, Canada. 4Brigham and Women’s Hospital and Dana-Farber Cancer Institute, Department of Radiation Oncology, Harvard Medical School, Boston, USA. 5Department of Physics and Astronomy, University of Manitoba, Winnipeg, Canada. 6Verspeeten Family Cancer Centre, London, Canada. 7Department of Oncology, Western University, London, Canada. *email: [ttrumpou@uwo.ca](ttrumpou@uwo.ca)  \n[www. nature.com/scientificreports/](www. nature.com/scientificreports/)  \nIdentifying the intracavitary applicator and interstitial needle tips is critical to en","cbCaifVOhFP6Se46","https://ap.wps.com/l/cbCaifVOhFP6Se46","pdf",3708408,12,"English","# Introduction\n## Background on HDR gynecologic brachytherapy and imaging needs\n## Applicators, localization requirements, and limitations of current modalities\n# Methods (as described in abstract)\n## Proposed ultrasound acquisition, registration, and fusion workflow\n## Validation using phantoms and patient procedures\n## Accuracy metrics: TRE and FLE\n# Results and implications\n## TRE/FLE outcomes across ultrasound–MR/CT registrations\n## Proof-of-concept rationale for further clinical studies","[{\"question\":\"What problem does the study address in gynecologic brachytherapy guidance?\",\"answer\":\"Accurate radiation delivery requires precise localization of intracavitary applicators at insertion. The study targets the need for reliable visualization and guidance during the procedure using 3D ultrasound fusion.\"},{\"question\":\"How was the proposed ultrasound fusion workflow validated?\",\"answer\":\"Validation used custom multi-modal pelvic phantoms and was demonstrated during two patient procedures. Fused ultrasound images were also registered to MR and CT for comparison.\"},{\"question\":\"What accuracy metrics and results were reported?\",\"answer\":\"Accuracy was quantified using target registration error (TRE) and fiducial localization error (FLE). Across all modality registrations, TRE and FLE had mean ± standard deviation values of 4.01 ± 1.01 mm and 0.43 ± 0.24 mm, respectively.\"}]","Three-dimensional trans-rectal and trans-abdominal ultrasound image fusion for the guidance of gynecologic brachytherapy procedures - a proof of concept study | PDF",1790009636]