[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-649994-105":59,"doc-detail-649994-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","third-party-agency-approval-code-an-s-installation-and-certification-requirements","THIRD PARTY AGENCY APPROVAL CODE - AN-S - Installation and certification requirements","","Third party agency approval code AN-S for an ATEX/IEC Ex associated apparatus and related safety drawings. Specifies installation must follow applicable country codes and practices, and that EXC+/EXC- associated apparatus must provide a linear output. Defines shunt switch wiring as nonincendive, for voltage-free contact connection with a certified barrier contact, and lists barrier parameter compliance conditions (Uo≤Ui, Io≤Ii, Co≤Ci plus cable capacitance, Lo≤Li plus cable inductance). Includes controlled drawing notices and engineering revision identifiers.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/third-party-agency-approval-code-an-s-installation-and-certification-requirements/649994/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/third-party-agency-approval-code-an-s-installation-and-certification-requirements/649994.png","ImageObject",300,407,{"name":92,"@type":93},"MrHarris58","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What must the installation comply with for the AN-S approval?","Question",{"text":112,"@type":113},"Installation must follow the codes and practices of the country in use.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What output characteristic is required for the EXC+/EXC- associated apparatus?",{"text":117,"@type":113},"The associated apparatus used for the EXC+/EXC- circuit must have a linear output.",{"name":119,"@type":110,"acceptedAnswer":120},"What are the key barrier parameter compliance conditions stated in the document?",{"text":121,"@type":113},"The document lists Uo ≤ Ui, Io ≤ Ii, Co ≤ Ci + Ccable, and Lo ≤ Li + Lcable.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},649994,1792813242,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},687212988360,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","# THIRD PARTY AGENCY APPROVAL CODE:AN-S\n\n\n| D  \u003Cbr>C  \u003Cbr>B  \u003Cbr>A   | 8  \u003Cbr>6  \u003Cbr>7   | 3  \u003Cbr>4  \u003Cbr>5   |  |  |  |  |  |  |  |  |  |  |  |  |  | D  \u003Cbr>C  \u003Cbr>B  \u003Cbr>A   |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  | SAFE AREA  \u003Cbr>HAZARDDUS AREA  \u003Cbr>EXC+  \u003Cbr>十  \u003Cbr>ASSDCIATED  \u003Cbr>TRANSMITTER  \u003Cbr>APPARATUS  \u003Cbr>EXC-  \u003Cbr>STD  \u003Cbr>Ex ic  \u003Cbr>ENTIT  \u003Cbr>Ui=28  \u003Cbr>SHUNT+  \u003Cbr>Ii=100  \u003Cbr>日  \u003Cbr>Ci=27  \u003Cbr>Li=0  \u003Cbr>SHUNT-  \u003Cbr>CH1  \u003Cbr>Pi=0.  \u003Cbr>SHUNT  \u003Cbr>SWITCH  \u003Cbr>米UNI  \u003Cbr>EXC+  \u003Cbr>BE_  \u003Cbr>AND  \u003Cbr>ASSDCIATED  \u003Cbr>TRANSMITTER  \u003Cbr>REQ  \u003Cbr>NC DPTION  \u003Cbr>APPARATUS  \u003Cbr>EXC-  \u003Cbr>(NDN-PDWERED,  \u003Cbr>AS   \u003Cbr>ISDLATED SHUNT)  \u003Cbr>CDN  \u003Cbr>WH  \u003Cbr>SHUNT+  \u003Cbr>SHUNT  \u003Cbr>SWITCH  \u003Cbr>SHUNT-  \u003Cbr>EXC+  \u003Cbr>TRANSMITTER  \u003Cbr>ASSDCIATED  \u003Cbr>QY DPTION  \u003Cbr>APPARATUS  \u003Cbr>EXC-  \u003Cbr>NO SHUNT CAL  \u003Cbr>1.INSTALLATIDN MUST BE IN ACCDRDANCE WITH THE  \u003Cbr>CDDES AND PRACTICES DF THE CDUNTRY IN USE  \u003Cbr>2.ASSDCIATED APPARATUS USED FDR THE EXC+/EXC-  \u003Cbr>CIRCUIT_MUST_HAVE A LINEAR DUTPUT AND BE   |  |  |  |  |  |  |  |  |  IIC T5(Ta=80°℃)  \u003Cbr>Y PARAMETERS:※  \u003Cbr>V  \u003Cbr>mA  \u003Cbr>.2nF  \u003Cbr>7W  \u003Cbr>TS ARE ALSD Ex_nA IIC AND CAN  \u003Cbr>INSTALLED WITHDUT BARRIERS  \u003Cbr> PER ZONE 2 INSTALLATION  \u003Cbr>UIREMENTS.WHEN INSTALLED  \u003Cbr>AN nA DEVICE,ELECTRICAL  \u003Cbr>NECTIONS CANNOT BE_SEPARATED  \u003Cbr>EN DEVICE IS ENERGIZED.  \u003Cbr>/s/A.Napieralski 10/1/08  \u003Cbr>CERTIFIE CONFORME a la EXECUTION   |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  | THIS IS A CDNTROLLED DRAWING  \u003Cbr>AND MAY NOT BE CHANGED WITHDUT  \u003Cbr>ENGINEERING AUTHDRIZATION   |  |  |  |  |  |  |\n|  | CERTIFIED WITH THE BARRIER PARAMETERS THAT MEET  \u003Cbr>THE FOLLOWING CDNDITIDNS  \u003Cbr>Uo ≤Ui  \u003Cbr>Io≤Ii  \u003Cbr>Co≤Ci +Ccable  \u003Cbr>Lo≤Li+Lcable  \u003Cbr>3.SHUNT SWITCH WIRING IS_NDNINCENDIVE AND IS FOR  \u003Cbr>CDNNECTION TD A VDLTAGE FREE_CDNTACT,DR  \u003Cbr>CERTIFIED_RELAY CDNTACT BARRIER WITH A  \u003Cbr>VDLTAGE FREE CDNTACT.   |  | UNLESS OTHERWISE SPECIFIED  \u003Cbr>DIMENSIONS ARE IN INCHES   | REVISIONS   |  |  |  | 2770 LONG ROAD  \u003Cbr>GP:50 Aerospace Div.  \u003Cbr>GRAND ISLAND,NY 14072  \u003Cbr>CAGE CODE:ON8Y7  \u003Cbr>TEL.NO.(716)773-9300 FAX NO.(716)773-5019   |  |  |  |  |  |  |  |  |\n|  |  |  | FRACTIONS±1/64  \u003Cbr>DECIMALS:  \u003Cbr>TOLERANCES:XX ±.01  \u003Cbr>.XXX_±.005  \u003Cbr>ANGLES ±1/2   | LET  \u003Cbr>Orig  \u003Cbr>1   | BY |ECN  \u003Cbr>DATE   |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  | AN|46  \u003Cbr>1/09/08  \u003Cbr>MM|865  \u003Cbr>6/3/11   |  |  | 0 SCALE  \u003Cbr>DRAWN:NA  \u003Cbr>SCALE:NA   |  |  | MATERIAL  \u003Cbr>NA   |  |  | DRAWN BY:  DATE  \u003Cbr>DW 01/09/08   |  |  |\n|  |  |  | 63√MACHINE FINISH(ALL SURFACES)  \u003Cbr>REMOVE BURRS &BREAK SHARP EDGES  \u003Cbr>.015 MAX.  \u003Cbr>MACHINE FLETS To二015R MAX.  \u003Cbr>ALL DIAMETERS TO BE CONCENTRIC  \u003Cbr>WITHIN 010_TIR.  \u003Cbr>CHAMFER ALL MALE THREADS 45'±5  \u003Cbr>TO MINOR DIAMETER  \u003Cbr>C'SINK ALL FEMALE THREADS 90±10  \u003Cbr>TO MAJOR DIAMETER   |  |  |  |  | DESIGNER  \u003Cbr>DW   | REVIEW DATE   |  |  | REVIEW DATE   |  | APPROVED     DATE   |  |  |\n|  |  |  |  |  |  |  |  | TITLE:ATEX/IEC Ex _ic IC  \u003Cbr>MDDELS 370 AN/GN   |  |  |  |  | DRAWING NO.  \u003Cbr>8C1-64.00-2   |  | REV.  \u003Cbr>1   |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n\n8  \n7  \n6  \n5  \n4  \n3  \n2","cbCaipF2SywEtjEK","https://ap.wps.com/l/cbCaipF2SywEtjEK","pdf",44836,"English","# Approval code\n## Installation requirements\n## Barrier parameter conditions\n## Shunt switch wiring requirements\n## Controlled drawing and revision info","[{\"question\":\"What must the installation comply with for the AN-S approval?\",\"answer\":\"Installation must follow the codes and practices of the country in use.\"},{\"question\":\"What output characteristic is required for the EXC+/EXC- associated apparatus?\",\"answer\":\"The associated apparatus used for the EXC+/EXC- circuit must have a linear output.\"},{\"question\":\"What are the key barrier parameter compliance conditions stated in the document?\",\"answer\":\"The document lists Uo ≤ Ui, Io ≤ Ii, Co ≤ Ci + Ccable, and Lo ≤ Li + Lcable.\"}]","THIRD PARTY AGENCY APPROVAL CODE - AN-S - Installation and certification requirements | PDF"]