[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-289294-105":59,"doc-detail-289294-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","thicknessgauge-sensor-system-for-inline-thickness-measurements","thicknessGAUGE - Sensor system for inline thickness measurements","","thicknessGAUGE provides a fully assembled sensor system for precise inline thickness measurements of strip materials, plates and sheets up to 50 mm. It uses two aligned optical distance sensors based on the difference principle, with factory calibration and fully automatic calibration supported by a parked measurement standard. An integrated linear axis enables traversing or fixed-track measurements, while in-situ calibration and temperature compensation ensure reliable results at selectable intervals. Compact integration is supported by a 24 V power supply, industrial PC software, and data monitoring, analysis, archiving, and SPC.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/thicknessgauge-sensor-system-for-inline-thickness-measurements/289294/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/thicknessgauge-sensor-system-for-inline-thickness-measurements/289294.png","ImageObject",300,407,{"name":92,"@type":93},"\tWilliam","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-17","2026-09-17",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",17,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"How does thicknessGAUGE measure thickness?","Question",{"text":113,"@type":114},"It uses two optical distance sensors on opposite sides of the material. The thickness is determined according to the difference principle, based on calibrated sensor working distance.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What calibration methods are used to ensure accuracy?",{"text":118,"@type":114},"Factory calibration aligns and calibrates the sensors. During operation, fully automatic in-situ calibration at selectable intervals is performed in the parking position, including temperature compensation.",{"name":120,"@type":111,"acceptedAnswer":121},"Which measurement modes and positioning options are available?",{"text":122,"@type":114},"The system supports traversing thickness measurement using an electromechanical drive and fixed-track measurements for center thickness (center-line) or thickness on the edges, including multi-track options depending on strip width models.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},289294,1789634921,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":130,"read_time":41},5909887254083,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","More Precision  \nthicknessGAUGE // Sensor system for inline thickness measurements  \nSensor system for precise inline thickness measurements thicknessGAUGE  \nThickness measurement with high precision  \nthicknessGAUGE sensor systems are used for precise thickness measurements of strip materials, plates and sheets up to 50 mm. Several models with different sensor types, measuring ranges and measuring widths enable inline thickness measurements of different materials and surfaces based on an unmatched price/performance ratio.  \nThis fully assembled system comprises astable frame on which two optical distance sensors are fixed, that detect the thickness of the measuring object according to the difference principle. The sensors are perfectly aligned to each other and calibrated during the assembly. Furthermore, thickness calibration at the factory ensures high precision.  \nA linear axis moves the sensor system from the parking position to the measuring position where a measurement standard for fully automatic calibration is placed.  \nOperating principle of thickness measurement  \nThe principle of dimensional, geometric thickness measurement includes one optical distance sensor on each side of the material. The distance (=working distance) between the two sensors is determined in a calibration process. The basis of the calibration is a DAkkS-certified measurement standard, to the thickness of which the sum of the distance values is added to determine the operating range.  \nCompact complete system for easy integration  \nThese compact systems are comprised of an integrated linear unit including motor control, a compact bus terminal box, an automatic calibration unit as well as a multi-touch PC with pre-installed software. The entire system is powered via a 24 V source.  \nExamples of customized modifications:  \n􀂃 Selectable cable lengths  \n􀂃 Customer-specific axis length  \n􀂃 Encoder  \n􀂃 Interface for fieldbus connection  \n􀂃 Digital inputs/outputs  \nFully automatic calibration enables reliable measurements (here: thicknessGAUGE C.LP)  \nAutomatic calibration and  \ntemperature compensation To compensate for effects of fluctuating temperatures, the thicknessGAUGE systems are equipped with an in-situ calibration, which is carried out in the parking position. Calibration is performed automatically and at freely selectable intervals. In addition to temperature compensation, in-situ calibration enables proper functioning of the system.  \nThe new class for inline thickness measurements thicknessGAUGE sensor systems are used for precise thickness measurement in numerous strip materials, plates and sheets. A linear unit with electromechanical drive enables thickness measurements in traversing mode. Alternatively, fixed track measurements are possible for center-line measurements (center thickness) or for thickness measurements on the edges.  \nFixed track measurement on the edges  \n(any strip width)  \nMulti-track thickness measurement  \n(any strip width)  \nFixed track center thickness measurement  \n(strip width max. 1200 mm with models with 600 mm measuring width)  \nTraversing thickness measurement  \n(strip width max. 600 mm with models with 600 mm measuring width)  \n100% quality control during production  \nThe thicknessGAUGE sensor systems are designed in such a way that they can be used as both initial equipment and for retrofitting of existing facilities. Based on high precision and equipped with intelligent sensor technology, these systems are used in various industries.  \nMetal production  \nThickness measurement of metal film, metal strips and metal plates  \nEnergy industry  \nThickness measurement of fuel cells and battery film (coated and uncoated)  \nMaterial engineering  \nThickness measurement of film, plastic plates, woven materials, wood and ceramics  \n3  \nModels  \nthicknessGAUGE  \nthicknessGAUGE C. LL  \nSensor technology used:  \nLaser triangulation displacement sensors  \n􀂃 Measuring range (thickness): 6 / 50 mm  \n􀂃 Accuracy: ±1 / ±5 µm  ","cbCaibyoqfUVk9Th","https://ap.wps.com/l/cbCaibyoqfUVk9Th","pdf",1800421,12,"English","# Operating principle of thickness measurement\n## Compact complete system for easy integration\n## Automatic calibration and temperature compensation\n## Measurement modes and applications\n## Sensor technology and performance\n## Software features","[{\"question\":\"How does thicknessGAUGE measure thickness?\",\"answer\":\"It uses two optical distance sensors on opposite sides of the material. The thickness is determined according to the difference principle, based on calibrated sensor working distance.\"},{\"question\":\"What calibration methods are used to ensure accuracy?\",\"answer\":\"Factory calibration aligns and calibrates the sensors. During operation, fully automatic in-situ calibration at selectable intervals is performed in the parking position, including temperature compensation.\"},{\"question\":\"Which measurement modes and positioning options are available?\",\"answer\":\"The system supports traversing thickness measurement using an electromechanical drive and fixed-track measurements for center thickness (center-line) or thickness on the edges, including multi-track options depending on strip width models.\"}]","thicknessGAUGE - Sensor system for inline thickness measurements | PDF"]