[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662335-105":59,"doc-detail-662335-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","thermostats-tp-pac01-a-installation-instructions","Thermostats - TP-PAC01-A - Installation Instructions","","Installation instructions for Carrier Performance Series AC/HP thermostat models (programmable and non-programmable), including safety considerations, introduction, and installation considerations. Covers wall-mounted low-voltage temperature control operation in single-piece or two-piece configurations, wiring and power requirements using 24VAC (Rh/Rc/C), and guidance for two-transformer vs single-transformer setups. Includes model options, outdoor and remote indoor temperature sensor support, and notes on system start-up, checkout, operation, troubleshooting, thermostat configuration records, and wiring diagrams.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/thermostats-tp-pac01-a-installation-instructions/662335/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/thermostats-tp-pac01-a-installation-instructions/662335.png","ImageObject",300,407,{"name":92,"@type":93},"McQueen","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What power input does the AC/HP thermostat require for proper operation?","Question",{"text":112,"@type":113},"The control is powered by 24VAC only, requiring 24VAC connected to the Rh and/or Rc and C terminals.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does a two-piece thermostat configuration differ from a single-piece installation?",{"text":117,"@type":113},"In two-piece configuration, relays are located near the equipment and Display Module connects to the Equipment Control Module using a two-wire connection. Single-piece installation requires more wiring and results in a higher profile.",{"name":119,"@type":110,"acceptedAnswer":120},"Is an outdoor temperature sensor included with the AC/HP control?",{"text":121,"@type":113},"No. The outdoor air temperature sensor is not included with the AC/HP Control and is available as an accessory (part number TSTATCCSEN01-B).","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662335,1793211928,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},5909890329169,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","| TP- PAC01-A, TP- PHP01-A\u003Cbr>TP- NAC01-A, TP- NHP01-A Performance™ Series\u003Cbr>AC / HP Thermostat | |\n| --- | --- |\n\nInstallation Instructions  \nA07049 A07048  \nProgrammable Control Non-Programmable Control  \nNOTE: Read the entire instruction manual before starting the installation.  \nUS patents: US7287709 B2, US20080147242 A1, USD582800 SI, US20060165149 A1, US6956463 B2 .  \nTABLE OF CONTENTS  \nPAGE  \nSAFETY CONSIDERATIONS ................................ 1  \nINTRODUCTION .......................................... 2  \nINSTALLATION CONSIDERATIONS .......................... 3  \nINSTALLATION ........................................... 6  \nSYSTEM START-UP AND CHECKOUT ...................... 39  \nOPERATIONAL INFORMATION ............................ 42  \nTROUBLESHOOTING ..................................... 46  \nWIRING DIAGRAMS ...................................... 50  \nTHERMOSTAT CONFIGURATION RECORD .................. 59  \nSAFETY CONSIDERATIONS  \nRead and follow manufacturer instructions carefully. Follow all local electrical codes during installation. All wiring must conform to local and national electrical codes. Improper wiring or installation may damage AC/HP Control.  \nRecognize safety information. This is the safety-alert symbol  . When you see this symbol on the equipment and in the instruction manual, be alert to the potential for personal injury.  \nUnderstand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.  \n1  \nINTRODUCTION  \nCarrier’s 7-day, 5/2-day, 1-day programmable and non-programmable Performance Series Thermostat Control is a wall-mounted, low-voltage temperature control in either a single unit or a two-piece unit. In two-piece configuration, the relays are located near the equipment and a two-wire connection is used between the Display Module and the Equipment Control Module. Single-piece installation requires more wiring and results in a higher profile. The Edge t Thermostat has no need for batteries to store user-configured settings in memory. During power loss its internal memory saves settings for unlimited time, and the clock continues to run for at least 24 hours. An extension of Carrier’s proven line of thermostats; it provides separate setpoints for heating and cooling.  \nIn the Edge Thermostat Control programmable configuration, different heating and cooling setpoints and times are programmable for 4 periods per day or 2 periods per day. Programming can be done for 7 days per week, 5/2 days per week, or 1 day. The programmable Thermostat Control can also be user configured as anon-programmable Thermostat Control.  \nThe non-programmable Thermostat Control features Touch’N’Go t settings for quick and easy temperature change without complicated programming schedules. And, its Touch ’N’Go technology enables the user to switch between three different user-configurable settings through intuitive buttons located just below the display.  \n2  \nINSTALLATION CONSIDERATIONS  \nPower  \nThis control is powered by 24VAC only. It requires 24VAC (Rh and/or Rc and C terminals) of the low-voltage transformer to be connected to it for proper operation. It will not operate without these 2 connections. Rh and Rc are connected via PCB breakout jumper. See Fig. 1. For applications using two 24VAC transformers, one in the indoor unit and one in the outdoor unit, connect the common from each to the C terminal. Connect R from the indoor unit to the Rh terminal. Connect R from the outdoor unit to the Rc terminal. Then, break jumper on the circuit board. The W signal is taken from the Rh pow","cbCaisPeDlqT4F4m","https://ap.wps.com/l/cbCaisPeDlqT4F4m","pdf",2922695,68,"English","# TABLE OF CONTENTS\n## SAFETY CONSIDERATIONS\n## INTRODUCTION\n## INSTALLATION CONSIDERATIONS\n## INSTALLATION\n## SYSTEM START-UP AND CHECKOUT\n## OPERATIONAL INFORMATION\n## TROUBLESHOOTING\n## WIRING DIAGRAMS\n## THERMOSTAT CONFIGURATION RECORD","[{\"question\":\"What power input does the AC/HP thermostat require for proper operation?\",\"answer\":\"The control is powered by 24VAC only, requiring 24VAC connected to the Rh and/or Rc and C terminals.\"},{\"question\":\"How does a two-piece thermostat configuration differ from a single-piece installation?\",\"answer\":\"In two-piece configuration, relays are located near the equipment and Display Module connects to the Equipment Control Module using a two-wire connection. Single-piece installation requires more wiring and results in a higher profile.\"},{\"question\":\"Is an outdoor temperature sensor included with the AC/HP control?\",\"answer\":\"No. The outdoor air temperature sensor is not included with the AC/HP Control and is available as an accessory (part number TSTATCCSEN01-B).\"}]","Thermostats - TP-PAC01-A - Installation Instructions | PDF",171]