[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-396653-105":59,"doc-detail-396653-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","thermostatic-expansion-valves-bulletin-10-10","Thermostatic Expansion Valves - Bulletin 10-10","","Bulletin 10-10 provides product information for thermostatic expansion valves with selective thermostatic charges, including part identification and ordering details for Borgen Systems (Parker Hannifin). The document highlights outstanding design features such as pin carrier alignment, balanced port design, corrosion-resistant materials, silver soldered connections, and adjustable superheat control. It also explains how the TEV maintains constant superheat at the evaporator outlet to regulate liquid refrigerant flow in direct expansion systems, and includes a table of contents for selection procedures, charge recommendations, capacity and quick reference materials, valve specifications, and terms of sale.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/thermostatic-expansion-valves-bulletin-10-10/396653/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/thermostatic-expansion-valves-bulletin-10-10/396653.png","ImageObject",300,407,{"name":92,"@type":93},"iuabcfuw","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-07","2026-09-26",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of a thermostatic expansion valve (TEV) in a direct expansion system?","Question",{"text":112,"@type":113},"The TEV controls the flow of liquid refrigerant entering the direct expansion (DX) evaporator by maintaining a constant superheat of refrigerant vapor at the evaporator outlet.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What does “superheat” mean in the TEV control process?",{"text":117,"@type":113},"Superheat is the difference between the actual temperature and the saturation temperature of the refrigerant corresponding to the suction pressure at the sensing bulb location.",{"name":119,"@type":110,"acceptedAnswer":120},"What ordering information is provided for Borgen part number 35345?",{"text":121,"@type":113},"The document provides phone ordering information at 800-383-7509 and includes an email contact at service@borgensystems.com, along with the part description and dimensions.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},396653,1790712971,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},3985747874027,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","800-383-7509  \nPart Description: Thermostatic Expansion Valve  \nSBQE, 3/8 X 1/2 X 1/4 ODF x 5'  \nBorgen Part Number: 35345  \nTo order this part from Borgen Systems: Phone 800-383-7509  \nEmail: [service@borgensystems.com](service@borgensystems.com)  \nApril 2011 / BULLETIN 10-10  \nThermostatic Expansion Valves  \nWith Selective Thermostatic Charges  \n⚠WARNING – USER RESPONSIBILITY  \nFailure or improper selection or improper use of the products described herein or related items can cause death, personal injury and property damage.  \nThis document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.  \nThe user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.  \nTo the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.  \nOFFER OF SALE  \nThe items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed “Offer of Sale” [available at www.parker.com](available at www.parker.com).  \nBULLETIN 10-10 — Page 1  \nt THERMOSTATIC EXPANSION VALVES  \n\n| 10 | Outstanding Features & Benefits of Sporlan Thermostatic Expansion Valves | • PIN CARRIER DESIGN (CONVENTIONAL VALVES)\u003Cbr>Provides precise pin and port alignment, and tighter seating.\u003Cbr>• BALANCED PORT DESIGN\u003Cbr>Provides perfect pin and port alignment, and prevents changes in pressure drop across the valve from influencing valve operation. Provides excellent control on applications with widely varying operating conditions.\u003Cbr>• MATERIALS OF CONSTRUCTION\u003Cbr>Pin and port materials offer maximum protection against corrosion and erosion.\u003Cbr>• SILVER SOLDERED CONNECTIONS\u003Cbr>For leakproof, high strength connection-to-body joints.\u003Cbr>• ADJUSTABLE SUPERHEAT DESIGN\u003Cbr>All standard valves are externally adjustable.\u003Cbr>superheat, the TEV keeps most of the evaporator surface active, while preventing liquid refrigerant from returning to the compressor. The ability of the TEV to match refrigerant flow to the rate at which refrigerant can be vaporized in the evaporator makes the TEV the ideal expansion device for most air conditioning and refrigeration applications. |\n| --- | --- | --- |\n| SELECTIVE THERMOSTATIC CHARGES\u003Cbr>Designed to provide optimum performance for all applications — air conditioning and heat pump, medium and low temperature refrigeration.\u003Cbr>THERMOSTATIC ELEMENT DESIGN\u003Cbr>Long lasting and field proven stainless steel diaphragm and welded element construction.\u003Cbr>DIAPHRAGM DESIGN\u003Cbr>Large flat diaphragm permits precise valve control.\u003Cbr>REPLACEABLE THERMOSTATIC ELEMENTS\u003Cbr>Field replaceable elements on all standard valves.\u003Cbr>ACCESSIBLE INTERNAL PARTS\u003Cbr>Durable, leakproof body joint construction allows the valve to be disassembled, and the internal parts cleaned and inspected.\u003Cbr>The thermostatic expansion valve (TEV) controls the flow of liquid refrigerant entering the direct expansion (DX) evaporator by maintaining a constant superheat of the refrigerant vapor at the outlet of the evaporator. The TEV controls the difference between the actual temp","cbCaieHNTLny53AR","https://ap.wps.com/l/cbCaieHNTLny53AR","pdf",3217598,41,"English","# Selection Procedure\n# Valve Nomenclature / Ordering Instructions\n# Recommended Thermostatic Charges\n# TEV Capacity Ratings for Refrigerants\n# Capacity Tables for Refrigerants\n# TEV Quick Reference Guide\n# Valve Specifications\n## Materials and Details of Construction\n## OEM Type Thermostatic Expansion Valves\n## Terms of Sale with Warranty Limitations","[{\"question\":\"What is the purpose of a thermostatic expansion valve (TEV) in a direct expansion system?\",\"answer\":\"The TEV controls the flow of liquid refrigerant entering the direct expansion (DX) evaporator by maintaining a constant superheat of refrigerant vapor at the evaporator outlet.\"},{\"question\":\"What does “superheat” mean in the TEV control process?\",\"answer\":\"Superheat is the difference between the actual temperature and the saturation temperature of the refrigerant corresponding to the suction pressure at the sensing bulb location.\"},{\"question\":\"What ordering information is provided for Borgen part number 35345?\",\"answer\":\"The document provides phone ordering information at 800-383-7509 and includes an email contact at service@borgensystems.com, along with the part description and dimensions.\"}]","Thermostatic Expansion Valves - Bulletin 10-10 | PDF",1790445966,103]