[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-468817-105":59,"doc-detail-468817-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","theoretical-study-of-high-order-velocity-focusing-achieved-with-single-stage-reflectron-time-of-flight-mass-spectrometry","Theoretical Study of High-Order Velocity Focusing Achieved with Single-Stage Reflectron Time-of-Flight Mass Spectrometry","","This study explores fundamental principles of reflectron time-of-flight (R-TOF) mass spectrometry (MS) and demonstrates how high-order velocity focusing can be achieved using a single-stage reflector. Conventional approaches required multistage reflectors for second-order velocity focusing, but this work shows that with a MALDI ion source and parameters optimized by the coupled space and velocity focusing (CSVF) principle, a single-stage reflector is sufficient. Delayed extraction compensates initial velocity spread more effectively than reflectors. Calculations predict up to 750,000 mass resolving power for m/z 10,000 with an effective 2.4 m flight length, or about 130,000 when detector temporal response limits are included. The model also reveals two focusing points along the flight path under second-order focusing.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/theoretical-study-of-high-order-velocity-focusing-achieved-with-single-stage-reflectron-time-of-flight-mass-spectrometry/468817/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/theoretical-study-of-high-order-velocity-focusing-achieved-with-single-stage-reflectron-time-of-flight-mass-spectrometry/468817.png","ImageObject",300,407,{"name":92,"@type":93},"Bintang","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What problem does the study address in reflectron time-of-flight mass spectrometry?","Question",{"text":112,"@type":113},"It addresses the principles and requirements for achieving high-order (second-order) velocity focusing in reflectron time-of-flight MS, which is crucial for improving mass resolving power.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Why does this work differ from conventional multistage reflectron designs?",{"text":117,"@type":113},"It shows that when a MALDI ion source is used and experimental parameters are optimized using the CSVF principle, a single-stage reflector can achieve second-order velocity focusing.",{"name":119,"@type":110,"acceptedAnswer":120},"How does delayed extraction compare with reflector-based compensation?",{"text":121,"@type":113},"The optimization model indicates that delayed extraction more effectively compensates the initial ion velocity spread than reflector design parameters.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},468817,1791377020,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":44,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":19,"preview_urls":145},962085564381,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","ACS Partner Journal  \nThis article is licensed under CC-BY 4.0   \n[pubs.acs.org/jasms](pubs.acs.org/jasms)  Article   \nTheoretical Study of High-Order Velocity Focusing Achieved with Single-Stage Reflectron Time-of-Flight Mass Spectrometry  \nYi-Hong Cai and Yi-Sheng Wang*  \n Cite This: J. Am. Soc. Mass Spectrom. 2026, 37, 33−41  \nRead Online  \n\n|  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| ACCESS   | Metrics & More |  |  Article Recommendations |  | *sı Supporting Information |\n\nABSTRACT: This study explores unexplained fundamental principles of reflectron time-of-flight (R-TOF) mass spectrometry (MS). Conventional calculations focusing on the ion trajectory in reflectors concluded that multistage reflectors are necessary to achieve second-order velocity focusing at ion detectors. This study demonstrates that in an instrument equipped with a matrixassisted laser desorption/ionization (MALDI) ion source a single-stage reflector can achieve second-order velocity focusing when the optimal experimental parameters predicted using the coupled space and velocity focusing (CSVF) principle are used. The optimization model indicates that the delayed extraction technique is more effective in compensating for the initial ion velocity spread than reflectors. The calculation shows that for ions with m/z of 10,000, the predicted maximum mass resolving power (Rm) can reach 750,000 using a single-stage R-TOF MS with an effective total length of about 2.4 m, or approximately 130,000 when accounting for the temporal response limit of ion detectors. The calculation model also reveals that in second-order focusing conditions, ions have two focusing points along the flight path, instead of just one at the detector as conventionally believed. The result indicates that the new model is critically important for the advancement of R-TOF MS.  \nKEYWORDS: coupled space and velocity focusing, reflectron time-of-flight mass spectrometry, single stage, delay extraction, flight-time topology  \n■ INTRODUCTION  \nAdvancing the analytical performance of mass spectrometers is important for applications demanding high-quality data. Particularly, the mass resolving power (Rm) of time-of-flight (TOF) mass spectrometry (MS) is a critical feature for accurate molecular analysis. Currently, reflectron (R)-TOFMS remains one of the key methods in MS analysis because reflectors can reduce nonideal instrumental factors, so as to achieve high-order ion focusing by compensating the energy difference of ions and extending ions’ flight distances and times to increase Rm. 1−3 Nowadays, a typical R-TOFMS can offer a Rm between 10,000 and 100,000.4,5 The basic principle of RTOFMS is also the foundation for the development of multiturn and multireflection TOF MS systems, which are advanced variants of R-TOFMS.5,6  \nThe Rm in R-TOF MS is mainly affected by nonideal factors in the ionization process, such as those in electrospray ionization (ESI) or matrix-assisted laser desorption/ionization (MALDI) ion sources.7,8 The primary factors include (1) the  \n© 2025 The Authors. Published by American Chemical Society  \ninitial spatial spread and (2) the initial velocity spread of ions.9−12 The initial velocity spread is particularly critical in the sense that ions with different initial velocities reach the detector at different times. The primary concept of reflectors to minimize their impact on Rm is allowing ions with higher initial velocity to spend a longer time in the reflector than those with lower initial velocity, thus achieving time focusing. Further instrumental optimization of reflectors to achieve high-order time focusing has been developed mainly by two significant advances, including the changes of the electric field from single-stage to (1) two-stage or (2) nonlinear (i.e., parabolic)  \nReceived: May 30, 2025  \nRevised: November 9, 2025  \nAccepted: November 12, 2025  \nPublished: November 26, 2025  \n[https://doi.org/10.1021/jasms.5c00167](https://doi.org/10.102","cbCaitQfRfn2RiVE","https://ap.wps.com/l/cbCaitQfRfn2RiVE","pdf",3631292,"English","# Abstract\n# Introduction","[{\"question\":\"What problem does the study address in reflectron time-of-flight mass spectrometry?\",\"answer\":\"It addresses the principles and requirements for achieving high-order (second-order) velocity focusing in reflectron time-of-flight MS, which is crucial for improving mass resolving power.\"},{\"question\":\"Why does this work differ from conventional multistage reflectron designs?\",\"answer\":\"It shows that when a MALDI ion source is used and experimental parameters are optimized using the CSVF principle, a single-stage reflector can achieve second-order velocity focusing.\"},{\"question\":\"How does delayed extraction compare with reflector-based compensation?\",\"answer\":\"The optimization model indicates that delayed extraction more effectively compensates the initial ion velocity spread than reflector design parameters.\"}]","Theoretical Study of High-Order Velocity Focusing Achieved with Single-Stage Reflectron Time-of-Flight Mass Spectrometry | PDF",1790774722,23,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/19d615c2797aca48e94a488afe673eaf.webp",983,1296,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/86aef60e0a7cd967625a2969b634a549.webp",982,1295,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/9ffc39461485f7e2cc0b81fbc699267e.webp",981,1293,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/87035c92ea3fa787a4723212e1cc95a8.webp",980,1292]