[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-376716-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-376716-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","the-diagnostic-power-of-circulating-mir-1246-in-screening-cancer-an-updated-meta-analysis","The Diagnostic Power of Circulating miR-1246 in Screening Cancer - An Updated Meta-analysis","","Updated meta-analysis evaluates extracellular circulating microRNA-1246 (miR-1246) as a diagnostic biomarker for screening common cancers. Searches in PubMed/MEDLINE, Web of Science, Cochrane Library, and Google Scholar up to November 28, 2022 were used to build summary ROC curves and pooled estimates, including AUC, DOR, sensitivity, and specificity. Twenty-nine studies (5914 participants) were analyzed, yielding strong overall discrimination with AUC 0.885, sensitivity 84.2%, and specificity 85.3%, and superior results for breast cancer.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/the-diagnostic-power-of-circulating-mir-1246-in-screening-cancer-an-updated-meta-analysis/376716/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/the-diagnostic-power-of-circulating-mir-1246-in-screening-cancer-an-updated-meta-analysis/376716.png","ImageObject",300,407,{"name":42,"@type":43},"Noah","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-23","2026-09-24",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",13,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What was the main goal of the updated meta-analysis?","Question",{"text":63,"@type":64},"To systematically assess the diagnostic performance of extracellular circulating miR-1246 for screening common cancers.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Which databases were searched and up to what date?",{"text":68,"@type":64},"PubMed/MEDLINE, Web of Science, Cochrane Library, and Google Scholar were searched until November 28, 2022.",{"name":70,"@type":61,"acceptedAnswer":71},"What were the pooled diagnostic accuracy results for miR-1246?",{"text":72,"@type":64},"The pooled AUC was 0.885, with a diagnostic odds ratio of 27.7, sensitivity of 84.2%, and specificity of 85.3%.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},376716,1790525268,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":55,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},8796095462418,"https://ap-avatar.wpscdn.com/avatar/80000253c1241d02b47?x-image-process=image/resize,m_fixed,w_180,h_180&k=1778826106357471780","Hindawi  \nOxidative Medicine and Cellular Longevity Volume 2023, Article ID 8379231, 13 pages [https://doi.org/10.1155/2023/8379231](https://doi.org/10.1155/2023/8379231)  \nReview Article  \nThe Diagnostic Power of Circulating miR-1246 in Screening Cancer: An Updated Meta-analysis  \nKhanh Quang Huynh , 1 Anh Tuan Le,2 Thang Thanh Phan ,3 Toan Trong Ho,3 Suong Phuoc Pho,3 Hang Thuy Nguyen,4 Binh Thanh Le,5 Thuc Tri Nguyen,5 and Son Truong Nguyen5  \n1 The Breast Unit, Cancer Center, Cho Ray Hospital, HCMC 700000, Vietnam  \n2Department of Chemo-Radiotherapy, Cancer Center, Cho Ray Hospital, HCMC 700000, Vietnam  \n3 The Laboratory D Unit, Cancer Center, Cho Ray Hospital, HCMC 700000, Vietnam  \n4Department of Clinical Pathology, Cho Ray Hospital, HCMC 700000, Vietnam  \n5Department of General Director, Cho Ray Hospital, HCMC 700000, Vietnam  \nCorrespondence should be addressed to Thang Thanh Phan; [thanhthangphan@gmail.com](thanhthangphan@gmail.com)  \nReceived 29 December 2022; Revised 28 March 2023; Accepted 11 April 2023; Published 20 April 2023  \nAcademic Editor: Ihtisham Bukhari  \nCopyright © 2023 Khanh Quang Huynh et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.  \nBackground. MicroRNA-1246 (miR-1246), an oncomiR that regulates the expression of multiple cancer-related genes, has been attracted and studied as a promising indicator of various tumors. However, diverse conclusions on diagnostic accuracy have been shown due to the small sample size and limited studies included. This meta-analysis is aimed at systematically assessing the performance of extracellular circulating miR-1246 in screening common cancers. Methods. We searched the PubMed/MEDLINE, Web of Science, Cochrane Library, and Google Scholar databases for relevant studies until November 28, 2022. Then, the summary receiver operating characteristic (SROC) curves were drawn and calculated area under the curve (AUC), diagnostic odds ratio (DOR), sensitivity, and speciﬁcity values of circulating miR-1246 in the cancer surveillance. Results. After selection and quality assessment, 29 eligible studies with 5914 samples (3232 cases and 2682 controls) enrolled in the ﬁnal analysis. The pooled AUC, DOR, sensitivity, and speciﬁcity of circulating miR-1246 in screening cancers were 0.885 (95% conﬁdence interval (CI): 0.827-0.892), 27.7 (95% CI: 17.1-45.0), 84.2%(95% CI: 79.4-88.1), and 85.3%(95% CI: 80.5-89.2), respectively. Among cancer types, superior performance was noted for breast cancer (AUC = 0:950, DOR = 98:5) compared to colorectal cancer (AUC = 0:905, DOR = 47:6), esophageal squamous cell carcinoma (AUC = 0:757, DOR = 8:0), hepatocellular carcinoma (AUC = 0:872, DOR = 18:6), pancreatic cancer (AUC = 0:767, DOR = 12:3), and others (AUC = 0:887, DOR = 27:5, P =0:007). No signiﬁcant publication bias in DOR was observed in the meta-analysis (funnel plot asymmetry test with P =0:652; skewness value = 0:672, P =0:071). Conclusion. Extracellular circulating miR-1246 may serve as a reliable biomarker with good sensitivity and speciﬁcity in screening cancers, especially breast cancer.  \n1. Introduction  \nDespite improvements in diagnosis and treatment, cancer is still burdened disease globally with the increased new cases and deaths over the years [1, 2] . Annual screening and earlier detection are crucial strategies that help to reduce cancer incidence and mortality [3–7] . Moreover, early detection of cancers leads to the use of less-aggressive interventions that improve patients’ quality of life. Many tools have been used  \nfrequently in the surveillance of cancers as low-dose computed tomography, mammography, endoscopy, ultrasound, and serum protein markers such as carbohydrate antigen 125, 15-3, 19-9, CYFRA 21-1, carcinoembryonic antigen, squamous cell carcinoma antigen, alpha-fetoprotein, and prostate-s","cbCaid4GxW2ZeoAK","https://ap.wps.com/l/cbCaid4GxW2ZeoAK","pdf",792924,"English","# Introduction\n# Oxidative Medicine and Cellular Longevity\n## Figure 1: Database searching and study selection\n## Figure 2: Quality of included studies regarding the risk of bias and applicability","[{\"question\":\"What was the main goal of the updated meta-analysis?\",\"answer\":\"To systematically assess the diagnostic performance of extracellular circulating miR-1246 for screening common cancers.\"},{\"question\":\"Which databases were searched and up to what date?\",\"answer\":\"PubMed/MEDLINE, Web of Science, Cochrane Library, and Google Scholar were searched until November 28, 2022.\"},{\"question\":\"What were the pooled diagnostic accuracy results for miR-1246?\",\"answer\":\"The pooled AUC was 0.885, with a diagnostic odds ratio of 27.7, sensitivity of 84.2%, and specificity of 85.3%.\"}]","The Diagnostic Power of Circulating miR-1246 in Screening Cancer - An Updated Meta-analysis | PDF",1790220818,33,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/f6dfbc52b716a3fed582ca3d437814d8.webp",983,1310,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/79dd8057d2600da9fca31a1f0c8c7638.webp",982,1309,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/88e99d20e37c1af6eca2f82b2d239f16.webp",981,1308,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/02a485563a35a6118a0d1c8e2f2be7e7.webp",980,1306]