[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-501578-105":59,"doc-detail-501578-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","test-report-for-ambulatory-hands-free-device-may-2014","Test Report for Ambulatory Hands Free Device - May 2014","","Wireless Patient Vital Signs Monitoring Device Operational Field Assessment report conducted by the U.S. Department of Homeland Security Science and Technology Directorate and partner stakeholders, dated May 2014. The executive summary describes a Dec. 3, 2013 evaluation of the ViSi Mobile device against operational requirements, with feedback from first responders and medical subject-matter experts. Recommendations address improved patient-information flow, streamlined vital-sign movement without transferring the laptop, possible hardware component removal, easier 3/5/12-lead ECG switching, reduced cabling, and extended functionality such as GPS, capnography, and defibrillator integration.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/test-report-for-ambulatory-hands-free-device-may-2014/501578/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/test-report-for-ambulatory-hands-free-device-may-2014/501578.png","ImageObject",300,407,{"name":92,"@type":93},"dawugda","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-25","2026-10-03",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What device and assessment were evaluated in the report?","Question",{"text":113,"@type":114},"The report evaluates the ViSi Mobile wireless patient vital signs monitoring device through an operational field assessment aligned to DHS operational requirements.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What operational improvements did participants recommend?",{"text":118,"@type":114},"Participants suggested improving the flow of patient information between medics and creating a seamless process for moving vital-sign information with the patient without transferring the mobile viewing laptop.",{"name":120,"@type":111,"acceptedAnswer":121},"What additional capabilities were suggested beyond basic life support?",{"text":122,"@type":114},"Suggestions included adding GPS, capnography, and integrating the system with a defibrillator, with the goal of extending system functionality over time.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},501578,1791040437,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146},3985747870947,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","Archived Content  \nIn an eﬀort to keep [DHS.gov](DHS.gov) current, this document has been archived and contains outdated information that may not reﬂect current policy or programs.  \nDepartment of Homeland Security Science and Technology Directorate First Responders Group  \nNational Urban Security Technology Laboratory New York, N.Y.  \nTest Report  \nWireless Patient Vital Signs Monitoring Device Operational Field Assessment  \nMay 2014  \nNational Urban Security Technology Laboratory  \nAuthor: Bhargav Patel  \n[Bhargav.patel@hq.dhs.gov](Bhargav.patel@hq.dhs.gov)  \nDISTRIBUTION NOTICE: Further dissemination only as directed by DHS Office of Policy DESTRUCTION NOTICE: Destroy by any method that will prevent disclosure of contents or reconstruction of the document  \nExecutive Summary  \nOn Dec. 3, 2013, the Department of Homeland Security (DHS) Science and Technology Directorate (S&T), Sotera Wireless® Inc., First Responders Group, and first receiver subject matter experts (SMEs) from around the nation convened at the American Medical Response facility in San Diego, Calif., to evaluate and assess the ViSi Mobile® . Sotera Wireless Inc., developed ViSi Mobile to meet the capability needs of the Wireless Patient Vital Signs Monitoring Device Operational Requirements Document, developed by DHS S&T with the assistance of emergency medical field SMEs. Participants offered varied years of experience and training and included two physicians, a trauma nurse, two firefighter/paramedics, and two paramedics from across the country.  \nAll participants responded positively to the operational capability of ViSi Mobile and provided suggestions for improvements. This included methods of improving the flow of patient information between medics and creating a seamless process for moving vital sign information with the patient without transferring the mobile viewing device (laptop) between medics.  \nAnother topic of discussion focused on the physical configuration of the device. The medics with Special Weapons and Tactics (SWAT) training and experience expressed a desire to remove certain components. All first responders expressed an interest in making the switch between a 3, 5, and 12-lead electrocardiogram easier, and potentially redesigning the chest connection method to further reduce the amount of wires involved.  \nAdditional suggestions for improvement varied, but all sought to extend the functionality of the system. Ideas included adding Global Positioning System, capnography (monitoring of carbon dioxide in respiratory gases), and integrating the system with a defibrillator.  \nIn summary, the assessment demonstrated ViSi Mobile’s value in improving basic life support medical care. ViSi Mobile achieves its goal of reducing entanglement and eliminating the need to constantly connect and disconnect to different vital signs monitoring systems. It also possesses the potential to continue to grow and improve to incorporate additional future capabilities such as defibrillation.  \nTable of Contents  \n1 Introduction .......................................................................................................................................... 4  \n1.1 Purpose ......................................................................................................................................... 4  \n1.2 Objectives...................................................................................................................................... 4  \n1.3 Requirements................................................................................................................................ 4  \n1.4 System Description ....................................................................................................................... 5  \n2 Operational Field Assessment Design................................................................................................... 7  \n2.1 Deviations from the Operational Field Assessment Plan...........","cbCain1yGGy4toqZ","https://ap.wps.com/l/cbCain1yGGy4toqZ","pdf",799195,21,"English","# 1 Introduction\n## 1.1 Purpose\n## 1.2 Objectives\n## 1.3 Requirements\n## 1.4 System Description\n# 2 Operational Field Assessment Design\n## 2.1 Deviations from the Operational Field Assessment Plan\n## 2.2 Summary of Events\n# 3 Data Analysis\n## 3.1 Operational Scenario Survey\n## 3.1.1 Data Analysis of the Operational Scenario Survey\n## 3.2 Phase 2 – Operational Scenario Debrief\n# 4 Results\n## 4.1 Operational Scenario Survey Results\n## 4.2 Operational Suitability Debrief and Feedback\n## 4.3 Requirements Compliance Matrix\n# 5 References:\n# 6 Definitions List\n# 7 Appendix A","[{\"question\":\"What device and assessment were evaluated in the report?\",\"answer\":\"The report evaluates the ViSi Mobile wireless patient vital signs monitoring device through an operational field assessment aligned to DHS operational requirements.\"},{\"question\":\"What operational improvements did participants recommend?\",\"answer\":\"Participants suggested improving the flow of patient information between medics and creating a seamless process for moving vital-sign information with the patient without transferring the mobile viewing laptop.\"},{\"question\":\"What additional capabilities were suggested beyond basic life support?\",\"answer\":\"Suggestions included adding GPS, capnography, and integrating the system with a defibrillator, with the goal of extending system functionality over time.\"}]","Test Report for Ambulatory Hands Free Device - May 2014 | PDF",1791020890,53]