[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-664517-105":3,"detail-sidebar-cat-0-en-105":79,"doc-detail-664517-en":129},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":72,"head_meta":74,"extra_data":76,"updated_unix":78},105,"en","tektronix-ct6-manual-for-high-frequency-ac-current-probe","Tektronix CT6 - Handbuch für High Frequency AC Current Probe","","Instruction manual for the Tektronix CT-6 high frequency AC current probe, including revision and warranty terms. Covers general safety overview, how to contact Tektronix, getting started, accessories and options, installation procedures, probe holder and optional evaluation board usage, and core operating basics such as interpreting current/voltage ratings, impedance matching, measuring and injecting current signals, and optimizing high-frequency performance. Provides calibration and evaluation line procedures, specifications, and performance verification with test records and alternate procedures.",{"@graph":14,"@context":71},[15,34,54],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/tektronix-ct6-manual-for-high-frequency-ac-current-probe/664517/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":48,"encodingFormat":47,"isAccessibleForFree":49,"interactionStatistic":50},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/tektronix-ct6-manual-for-high-frequency-ac-current-probe/664517.png","ImageObject",300,407,{"name":42,"@type":43},"Supernature","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-29",true,{"@type":51,"interactionType":52,"userInteractionCount":26},"InteractionCounter",{"@type":53},"ViewAction",{"@type":55,"mainEntity":56},"FAQPage",[57,63,67],{"name":58,"@type":59,"acceptedAnswer":60},"What warranty coverage does Tektronix provide for the CT-6 probe?","Question",{"text":61,"@type":62},"Tektronix warrants the product against defects in materials and workmanship for one year from the shipment date. During the warranty period, Tektronix may repair the product or replace it without charge for parts and labor.","Answer",{"name":64,"@type":59,"acceptedAnswer":65},"How does the manual recommend installing the CT-6 probe?",{"text":66,"@type":62},"The manual includes installation steps, including using the probe holder and, when applicable, mounting the current probe on the optional evaluation board as part of the setup.",{"name":68,"@type":59,"acceptedAnswer":69},"What procedures are included to verify frequency response and sensitivity?",{"text":70,"@type":62},"The manual provides performance verification sections with required equipment, preparation steps, frequency response and sensitivity setup using a digital oscilloscope, and an alternate procedure using a network analyzer, including calibration steps and test record sections.","https://schema.org",{"og:url":32,"og:type":73,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":75,"canonical":32},"index,follow",{"doc_id":77,"site_id":7},664517,1793258196,{"code":4,"msg":80,"data":81},"success",[82,86,90,94,99,103,108,113,118,121,125],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":83,"show_sort_weight":84,"slug":85},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":87,"show_sort_weight":88,"slug":89},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},"Exam",70,"exam",{"id":95,"doc_module":4,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},5,"Comic",60,"comic",{"id":100,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":101,"slug":102},6,50,"technology",{"id":104,"doc_module":4,"doc_module_name":25,"category_name":105,"show_sort_weight":106,"slug":107},7,"Healthcare",40,"healthcare",{"id":109,"doc_module":4,"doc_module_name":25,"category_name":110,"show_sort_weight":111,"slug":112},8,"Research & Report",30,"research-report",{"id":114,"doc_module":4,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},9,"Religion & Spirituality",20,"religion-spirituality",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":119,"show_sort_weight":116,"slug":120},"World Cup","world-cup",{"id":122,"doc_module":4,"doc_module_name":25,"category_name":123,"show_sort_weight":122,"slug":124},10,"Lifestyle","lifestyle",{"id":126,"doc_module":4,"doc_module_name":25,"category_name":127,"show_sort_weight":95,"slug":128},19,"General","general",{"code":4,"msg":80,"data":130},{"doc_id":77,"user_id":131,"nickname":42,"user_avatar":132,"doc_module":4,"category_id":100,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":26,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":138,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":78,"read_time":143},962093270004,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Instruction Manual  \nCT-6  \nHigh Frequency AC Current Probe 071-0453-00  \nRevision A  \nCopyright 􀀁 Tektronix, Inc. All rights reserved.  \nTektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.  \nTektronix Inc., P.O. Box 500, Beaverton, OR. 97077  \nTEKTRONIX and TEK are registered trademarks of Tektronix, Inc.  \nWARRANTY  \nTektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If a product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.  \nIn order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is toa location within the country in which the Tektronix service center is located. Customershall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.  \nThis warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.  \nTHIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.  \nTable of Contents  \nGeneral Safety Summary ............................ v  \nContacting Tektronix ................................ vii  \nGetting Started ..................................... 1  \nAccessories and Options .............................. 2  \nStandard Accessories .............................. 2  \nOptions ......................................... 2  \nOptional Accessories .............................. 2  \nInstallation ......................................... 3  \nProbe Holder ....................................... 7  \nEvaluation Board (Optional) ........................... 8  \nOperating Basics ................................... 9  \nInterpreting the Current and Voltage Ratings .............. 9  \nMatching Impedances ................................ 10  \nMeasuring Current ................................... 11  \nInjecting Current Signals .............................. 12  \nOptimizing Performance at High Frequencies ............. 13  \nCircuit Equivalent ................................ 13  \nSelecting the Wire Size and Length ................... 14  \nPositioning the Probe .............................. 14  \nGround Side and S","cbCaiaSZfbAHI3jO","https://ap.wps.com/l/cbCaiaSZfbAHI3jO","pdf",232436,46,"English","# General Safety Summary\n# Contacting Tektronix\n# Getting Started\n# Accessories and Options\n## Standard Accessories\n## Options\n## Optional Accessories\n# Installation\n## Probe Holder\n## Evaluation Board (Optional)\n# Operating Basics\n## Interpreting the Current and Voltage Ratings\n## Matching Impedances\n## Measuring Current\n## Injecting Current Signals\n## Optimizing Performance at High Frequencies\n# Specifications\n# Performance Verification\n## Equipment Required\n## Preparation\n# CT-6 Test Record\n# Frequency Response and Sensitivity – Alternate Procedure\n# CT-6 Test Record – Alternate Procedure","[{\"question\":\"What warranty coverage does Tektronix provide for the CT-6 probe?\",\"answer\":\"Tektronix warrants the product against defects in materials and workmanship for one year from the shipment date. During the warranty period, Tektronix may repair the product or replace it without charge for parts and labor.\"},{\"question\":\"How does the manual recommend installing the CT-6 probe?\",\"answer\":\"The manual includes installation steps, including using the probe holder and, when applicable, mounting the current probe on the optional evaluation board as part of the setup.\"},{\"question\":\"What procedures are included to verify frequency response and sensitivity?\",\"answer\":\"The manual provides performance verification sections with required equipment, preparation steps, frequency response and sensitivity setup using a digital oscilloscope, and an alternate procedure using a network analyzer, including calibration steps and test record sections.\"}]","Tektronix CT6 - Handbuch für High Frequency AC Current Probe | PDF",116]