[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-656769-105":59,"doc-detail-656769-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","technical-specification-renewal-of-dry-well-sewage-pumping-stations","Technical Specification - Renewal of Dry Well Sewage Pumping Stations","","Technical specification for renewing dry well sewage pumping stations, providing revision details, introduction, copyright notes, and acronym references. Defines general terms and coverage, sets out scope and proprietary items, and lists referenced documents. Specifies general SPS requirements with design and overall compliance expectations. Details subsystem requirements for dry well components (main pumps, sump pump, pipework, valves, access, supports, cleaning, lifting facilities, flood gates, bund walls) and continues with wet well provisions and inlet maintenance hole, valve chamber, and emergency bypass arrangement requirements.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/technical-specification-renewal-of-dry-well-sewage-pumping-stations/656769/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/technical-specification-renewal-of-dry-well-sewage-pumping-stations/656769.png","ImageObject",300,407,{"name":92,"@type":93},"iuabcfuw","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-25",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the document’s revision and introductory sections about?","Question",{"text":112,"@type":113},"The document includes revision details, an introduction, copyright information, and an acronyms section. It also provides general terms and definitions to standardize terminology.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What does the specification cover for the dry well system?",{"text":117,"@type":113},"It covers main pumps, sump pump, dry well pipework, valves, access requirements, redundant pump plinths and valve supports, cleaning, lifting facilities, and flood gates and bund walls.",{"name":119,"@type":110,"acceptedAnswer":120},"What requirements are included beyond the dry well?",{"text":121,"@type":113},"The specification continues with wet well requirements, inlet maintenance hole elements, valve chamber pipework and components, and an emergency bypass arrangement.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},656769,1793029585,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},3985747874027,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Technical Specification-Renewal of Dry Well Sewage Pumping Stations  \nTable of Contents  \nRevision details............................................................................................................................. 4  \nIntroduction ................................................................................................................................... 6  \nCopyright ....................................................................................................................................... 6  \nAcronyms ...................................................................................................................................... 6  \nGeneral Terms and Definitions .................................................................................................... 7  \n1. General............................................................................................................................. 8  \n1.1 Scope ................................................................................................................................................. 8  \n1.2 Proprietary items .............................................................................................................................. 8  \n2. Referenced documents ................................................................................................... 9  \n3. General SPS requirements ........................................................................................... 10  \n3.1 Design .............................................................................................................................................. 10  \n3.2 General requirements .................................................................................................................... 10  \n4. Dry well .......................................................................................................................... 13  \n4.1 Main pumps..................................................................................................................................... 13  \n4.2 Sump pump ..................................................................................................................................... 17  \n4.3 Dry well pipework ........................................................................................................................... 18  \n4.4 Dry well valves ................................................................................................................................ 20  \n4.5 Dry well access ............................................................................................................................... 21  \n4.6 Redundant pump plinths and valve supports ............................................................................. 22  \n4.7 Dry Well Cleaning ........................................................................................................................... 22  \n4.8 Lifting facilities ............................................................................................................................... 22  \n4.9 Flood gates and bund walls .......................................................................................................... 23  \n5. Wet well.......................................................................................................................... 23  \n5.1 General ............................................................................................................................................ 23  \n5.2 Existing access steelwork ............................................................................................................. 23  \n5.3 Wet well isolation ........................................................................................................................... 24  \n5.4 Hatches .................................................................................","cbCaigonV4l3Pt20","https://ap.wps.com/l/cbCaigonV4l3Pt20","pdf",555164,45,"English","# Revision details\n# Introduction\n# Copyright\n# Acronyms\n# General Terms and Definitions\n# 1. General\n## 1.1 Scope\n## 1.2 Proprietary items\n# 2. Referenced documents\n# 3. General SPS requirements\n## 3.1 Design\n## 3.2 General requirements\n# 4. Dry well\n## 4.1 Main pumps\n## 4.2 Sump pump\n## 4.3 Dry well pipework\n## 4.4 Dry well valves\n## 4.5 Dry well access\n## 4.6 Redundant pump plinths and valve supports\n## 4.7 Dry Well Cleaning\n## 4.8 Lifting facilities\n## 4.9 Flood gates and bund walls\n# 5. Wet well\n## 5.1 General\n## 5.2 Existing access steelwork\n## 5.3 Wet well isolation\n## 5.4 Hatches\n## 5.5 Wet well flushing\n# 6. Inlet maintenance hole\n## 6.1 Existing access steelwork\n## 6.2 Access hatches\n## 6.3 High level inlet pipe\n# 7. Valve chamber\n## 7.1 Pipework and fittings\n## 7.2 Below ground pipework\n## 7.3 Valve chamber valves\n## 7.4 Valve chamber covers\n## 7.5 Penetrations\n## 7.6 Access into valve chamber\n# 8. Emergency bypass arrangement\n## 8.1 Emergency bypass arrangement","[{\"question\":\"What are the document’s revision and introductory sections about?\",\"answer\":\"The document includes revision details, an introduction, copyright information, and an acronyms section. It also provides general terms and definitions to standardize terminology.\"},{\"question\":\"What does the specification cover for the dry well system?\",\"answer\":\"It covers main pumps, sump pump, dry well pipework, valves, access requirements, redundant pump plinths and valve supports, cleaning, lifting facilities, and flood gates and bund walls.\"},{\"question\":\"What requirements are included beyond the dry well?\",\"answer\":\"The specification continues with wet well requirements, inlet maintenance hole elements, valve chamber pipework and components, and an emergency bypass arrangement.\"}]","Technical Specification - Renewal of Dry Well Sewage Pumping Stations | PDF",1792970801,113]