[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-350818-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-350818-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","technical-feasibility-of-ivim-for-prostate-cancer-imaging-using-high-amplitude-whole-body-gradient-system-with-spiral-readout-and-velocity-compensated-diffusion-encoding","Technical Feasibility of IVIM for Prostate Cancer Imaging Using High-Amplitude Whole-Body Gradient System With Spiral Readout and Velocity-Compensated Diffusion Encoding","","Intravoxel incoherent motion (IVIM) enables diffusion and perfusion sensitivity, but limited repeatability and reproducibility of IVIM parameters restrict clinical adoption. This study develops a high-quality prostate IVIM imaging framework by combining velocity-compensated diffusion encoding with spiral readout on a 3 T MRI system using 300 mT/m gradients. IVIM parameters were assessed in five men, with and without prostate cancer, focusing on SNR, visual map quality, and repeatability. High in-plane resolution images achieved SNR > 3 in 91% of voxels at the highest b-value of 500 s/mm2, and parameter maps showed fine tissue features. Voxel-wise and ROI analyses demonstrated high repeatability across prostatic zones and prostate cancer.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/technical-feasibility-of-ivim-for-prostate-cancer-imaging-using-high-amplitude-whole-body-gradient-system-with-spiral-readout-and-velocity-compensated-diffusion-encoding/350818/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/technical-feasibility-of-ivim-for-prostate-cancer-imaging-using-high-amplitude-whole-body-gradient-system-with-spiral-readout-and-velocity-compensated-diffusion-encoding/350818.png","ImageObject",300,407,{"name":42,"@type":43},"pixelkiddo","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-27","2026-09-22",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",10,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What problem does IVIM face in clinical use for prostate imaging?","Question",{"text":63,"@type":64},"IVIM parameter estimation suffers from poor repeatability and reproducibility, largely due to high demands on data quality and the challenges of prostate imaging such as small anatomy and motion-related distortions.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How does the proposed method improve IVIM acquisition?",{"text":68,"@type":64},"It uses a custom pulse sequence that combines velocity-compensated diffusion encoding with spiral readout on a 3 T MRI system with strong 300 mT/m gradients to improve signal precision and quality of IVIM parameter maps.",{"name":70,"@type":61,"acceptedAnswer":71},"How were the technical performance and repeatability evaluated?",{"text":72,"@type":64},"Performance was assessed using signal-to-noise ratio (SNR), visual quality of IVIM parameter maps, and parameter repeatability through voxel-wise and ROI-based analysis across prostatic zones and prostate cancer.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},350818,1790395729,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":55,"slug":125},"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},962090883892,"https://ap-avatar.wpscdn.com/avatar/e00115db34f3e0f11b?x-image-process=image/resize,m_fixed,w_180,h_180&k=1790152879550218658","NMR in Biomedicine  \nRESEARCH ARTICLE  OPEN ACCESS   \nTechnical Feasibility ofIVIM for Prostate Cancer Imaging Using High-Amplitude Whole-Body Gradient System With Spiral Readout and Velocity-Compensated Diffusion Encoding  \nMalwina Molendowska1,2  | Ivan A. Rashid3  | Kieran Foley4  | Lars Mueller5  | Lars E. Olsson3,6  | Patrik Brynolfsson6  | Filip Szczepankiewicz1   \n1Medical Radiation Physics, Lund University, Lund, Sweden | 2Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, UK | 3Department of Translational Medicine, Medical Radiation Physics, Lund University, Malmo, Sweden | 4Division of Cancer and Genetics, School of Medicine, Cardiff University, Cardiff, UK | 5Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK | 6Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skane University Hospital, Lund, Sweden  \nCorrespondence: Malwina Molendowska ([malwina.molendowska@med.lu.se](malwina.molendowska@med.lu.se))  \nReceived: 27 February 2026 | Revised: 9 July 2026 | Accepted: 7 August 2026  \nKeywords: IVIM | perfusion | prostate cancer | strong gradients | velocity compensation  \nABSTRACT  \nIntravoxel incoherent motion (IVIM) is sensitive to tissue diffusion and perfusion and has spurred great interest in various pathologies such as prostate cancer. However, poor repeatability and reproducibility of IVIM parameters hamper its widescale adoption in the clinics. To address this, improvements to the IVIM data acquisition and analysis are necessary. The purpose of this study was to develop a framework for high-quality IVIM imaging of the prostate. To boost signal precision and quality ofIVIM parameter maps, we used a custom pulse sequence to combine velocity-compensated diffusion encoding with spiral readout at a high-performance 3 T MRI system with 300 mT/m gradients. IVIM parameters were evaluated in a cohort of five men with and without prostate cancer. Technical performance was assessed in terms of the signal-to-noise ratio (SNR), visual quality of IVIM parameter maps and parameter repeatability. High in-plane resolution images of the prostate were obtained with SNR > 3 (i.e., noise floor level) in 91% of voxels at the highest b-value of 500 s/mm2 . The parameter maps exhibited high quality with fine features recovered in tissue diffusivity and perfusion fraction maps. Voxel-wise and ROI-based analysis revealed high repeatability of the parameters at single subject and group level across main prostatic tissue classes (peripheral and transitional zones) and prostate cancer. A combination of velocity-compensated diffusion encoding, spiral readout and strong gradients enables high-quality IVIM imaging in the prostate. Our framework may advance IVIM as a reliable imaging biomarker in prostate.  \n1 | Introduction  \nIntravoxel incoherent motion (IVIM) is a diffusion MRI (dMRI) method that enables mapping of tissue microstructure and perfusion, without relying on exogenous contrast agents [1] . The  \npotential of IVIM has been demonstrated across various organs and pathologies [2–5], resulting in promising candidates for imaging biomarkers, e.g., for the diagnosis of prostate cancer and its monitoring [6, 7] . However, the estimation of IVIM parameters is challenging due to ill-posedness, which places a relatively  \nThis is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.  \n© 2026 The Author(s). NMR in Biomedicine published by John Wiley & Sons Ltd.  \nNMR in Biomedicine, 2026; 39:e70384 1 of 13  \n[https://doi.org/10.1002/nbm.70384](https://doi.org/10.1002/nbm.70384)  \nhigh demand on data quality. As a result, several studies have shown unreliable parameter estimation and contradictory findings [8] .  \nThese challenges are further exacerbated in prostate imaging, which suffers from relatively ","cbCaikwZjz9Yewuy","https://ap.wps.com/l/cbCaikwZjz9Yewuy","pdf",10302141,13,"English","# Introduction\n## IVIM principles and challenges in prostate imaging\n## Data quality, parameter estimation methods, and standardisation\n## Velocity-compensated diffusion encoding and advanced readout strategies","[{\"question\":\"What problem does IVIM face in clinical use for prostate imaging?\",\"answer\":\"IVIM parameter estimation suffers from poor repeatability and reproducibility, largely due to high demands on data quality and the challenges of prostate imaging such as small anatomy and motion-related distortions.\"},{\"question\":\"How does the proposed method improve IVIM acquisition?\",\"answer\":\"It uses a custom pulse sequence that combines velocity-compensated diffusion encoding with spiral readout on a 3 T MRI system with strong 300 mT/m gradients to improve signal precision and quality of IVIM parameter maps.\"},{\"question\":\"How were the technical performance and repeatability evaluated?\",\"answer\":\"Performance was assessed using signal-to-noise ratio (SNR), visual quality of IVIM parameter maps, and parameter repeatability through voxel-wise and ROI-based analysis across prostatic zones and prostate cancer.\"}]","Technical Feasibility of IVIM for Prostate Cancer Imaging Using High-Amplitude Whole-Body Gradient System With Spiral Readout and Velocity-Compensated Diffusion Encoding | PDF",1790091280,33,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/9a0be53ef789b6326932caa057294e61.webp",983,1291,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/f13dfbc699b62e5dba5e2f40b43f3d79.webp",982,1290,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/3b0ecdcaba0f4b621fe575888ad6b07a.webp",981,1289,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/8704c8c8d1c38cee26011c18135ea83b.webp",980,1287]