[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-677200-105":59,"doc-detail-677200-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","tdc-installation-manual-door-operators","TDC Installation Manual - Door Operators","","Installation and commissioning guide for LiftMaster industrial DC door operators covering models JDC, JHDC, and TDC, including jackshaft, hoist, and trolley configurations for commercial doors up to specified weights. Provides safety requirements, voltage selection, electrical ratings, operator specifications and dimensions, assembly and installation steps, wiring, battery backup considerations, wall controller setup, programming of radio and myQ devices, and system testing for monitored entrapment protection devices. Includes maintenance schedules, accessories, service parts, and a two-year warranty.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/tdc-installation-manual-door-operators/677200/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/tdc-installation-manual-door-operators/677200.png","ImageObject",300,407,{"name":92,"@type":93},"dhado","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":101,"interactionType":102,"userInteractionCount":8},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"Who is allowed to install and service these operators?","Question",{"text":111,"@type":112},"Install and service must be performed by a trained door systems technician only.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"Which safety and security requirements apply to commercial door operators?",{"text":116,"@type":112},"The manual emphasizes monitored entrapment protection requirements such as UL 325, and notes that Security+ 2.0 sends a new code with each button press.",{"name":118,"@type":109,"acceptedAnswer":119},"How does the manual guide commissioning and testing after installation?",{"text":120,"@type":112},"It includes quick start commissioning and a commissioning flow, plus testing steps for entrapment protection devices, wall controller menu access, and limit adjustment.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},677200,1793777838,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":21,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":142},5909893218464,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","Industrial DC Operators  \nModels JDC, JHDC, and TDC  \nDC Jackshaft, Hoist, and Trolley For Doors up to 700, 1200, and 2200 lbs  \nNOT FOR RESIDENTIAL USE  \nNOT FOR RESIDENTIAL USE  \n• Please read this manual and the enclosed safety materials completely, prior to installation and use!  \n• This product is to be installed and serviced by a trained door systems technician ONLY.  \n• These operators are compatible with myQ®, myQ® Smart Facility Access™, and Security+ 2.0® accessories.  \n• These operators are Wi-Fi® compatible.  \n2 YEAR WARRANTY  \nSerial \\#   Installation Date    \nScan here for LiftMaster support videos and content.  \nTable of Contents  \nSafety Information 3  \nSafety Symbol and Signal Word Review..................3  \nPlanning 4  \nIntroduction 5  \nVoltage Selection .......................................5  \nModel Electrical Ratings.................................5  \nOperator Specifications 6  \nOperator Dimensions 7  \nJackshaft (JDC) and Hoist (JHDC) .......................7  \nTDC Trolley .............................................8  \nBattery Backup .........................................9  \nTDC Trolley Operators 10  \nCarton Inventory ...................................... 10  \nDescription ........................................... 10  \nHardware ............................................. 10  \nTDC Trolley Assembly 11  \nAssemble the Operator ............................... 11  \nInstall the Chain ....................................... 12  \nTDC Trolley Installation 13  \nInstall the Header Bracket ............................. 13  \nAttach the Track to the Header Bracket and Hang the Operator .............................................. 14  \nAttach the Door Arm and Bracket ..................... 15  \nJackshaft (JDC) and Hoist (JHDC) Operators 16  \nCarton Inventory ...................................... 16  \nDescription ........................................... 16  \nDoor Sprockets ....................................... 16  \nJDC/JHDC Assembly 17  \nConfigure the Operator ............................... 17  \nApplying AC Power .................................... 17  \nBattery Backup Wiring 18  \nJDC/JHDC Installation 19  \nDetermine Mounting Location......................... 19  \nMount the Operator ................................... 20  \nSecure the Chain Hoist ................................ 20  \nManual Release 21  \nEmergency Disconnect System Model TDC ........... 21  \nEmergency Disconnect System Model JHDC.......... 21  \nWiring 22  \nPower and Ground .................................... 22  \nVoltage Selection ..................................... 22  \nWall Controller Installation 23  \nEntrapment Protection 24  \nMonitored Entrapment Protection ..................... 24  \nInstall the Monitored Light Curtain (Optional) .......... 25  \nCable Tension Monitors 26  \nInstall the Cable Tension Monitor(s) (Optional) ......... 26  \nTesting 27  \nTest all Entrapment Protection Devices ................ 27  \nTest Wall Controller Menu Access ..................... 27  \nTest Limit Adjustment ................................. 27  \nWiring Diagram 28  \nProgramming 29  \nQuick Start Commissioning ........................... 29  \nManual Commissioning Program Flow ................. 29  \nOperating Modes ..................................... 32  \nDetermine Operating Mode ........................... 33  \nDetermine and Set Operating Mode ................... 34  \nProgrammable Inputs ................................. 42  \nRadio ................................................. 42  \nProgramming Remote Controls and myQ® Devices .... 42  \nErasing Programmed Devices ......................... 42  \nReset Defaults ........................................ 42  \nmyQ® Smart Facility Access ........................... 43  \nSetup a myQ® Smart Facility Access Account ......... 43  \nProvisioning Wi-Fi ..................................... 43  \nAuxiliary Relays Accessory Kit (AUXREL) 44  \nConfigure the Relay Adapter .......................... 44  \nTroubleshooting","cbCaiaO6qKcIVqiR","https://ap.wps.com/l/cbCaiaO6qKcIVqiR","pdf",9959193,"English","# Safety Information\n## Safety Symbol and Signal Word Review\n# Planning\n# Introduction\n# Operator Specifications\n## Jackshaft (JDC) and Hoist (JHDC)\n## TDC Trolley\n# Assembly and Installation\n## TDC Trolley Assembly\n## Jackshaft (JDC) and Hoist (JHDC) Operators\n# Wiring\n## Power and Ground\n## Voltage Selection\n## Wall Controller Installation\n# Testing\n## Test all Entrapment Protection Devices\n## Test Wall Controller Menu Access\n# Programming\n## Quick Start Commissioning\n## Operating Modes\n# Troubleshooting\n# Maintenance\n# Warranty","[{\"question\":\"Who is allowed to install and service these operators?\",\"answer\":\"Install and service must be performed by a trained door systems technician only.\"},{\"question\":\"Which safety and security requirements apply to commercial door operators?\",\"answer\":\"The manual emphasizes monitored entrapment protection requirements such as UL 325, and notes that Security+ 2.0 sends a new code with each button press.\"},{\"question\":\"How does the manual guide commissioning and testing after installation?\",\"answer\":\"It includes quick start commissioning and a commissioning flow, plus testing steps for entrapment protection devices, wall controller menu access, and limit adjustment.\"}]","TDC Installation Manual - Door Operators | PDF",176]