[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662209-105":59,"doc-detail-662209-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","tc5-2v2sa-users-manual-rev-05","TC5-2V2SA - User's Manual - REV. 05","","User manual for the TC5-2V2SA electronic temperature controller used for environmental control in livestock buildings. It explains safety precautions and installation requirements, including operating temperature limits, ventilation placement, and wiring-related guidance. The manual covers controller features such as adjustable fan stages, temperature and minimum ventilation speed curves, humidity compensation, motor type selection, heating and alarm settings, test mode, troubleshooting, and factory settings, supported by a structured table of contents.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/tc5-2v2sa-users-manual-rev-05/662209/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/tc5-2v2sa-users-manual-rev-05/662209.png","ImageObject",300,407,{"name":92,"@type":93},"Alexandar","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of the TC5-2V2SA temperature controller?","Question",{"text":112,"@type":113},"It maintains a target temperature in livestock buildings by controlling ventilation and heating equipment, including variable-speed fans and optional mist cooling.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What key safety precautions does the manual emphasize?",{"text":117,"@type":113},"Install supplementary natural ventilation and a back-up thermostat for at least one cooling stage, use additional protection on the supply circuit, keep the controller location between 32°F and 104°F (0°C to 40°C), and do not spray water on the controller.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the controller manage ventilation and humidity?",{"text":121,"@type":113},"It supports temperature curve scheduling and minimum ventilation speed curves, and stage 1 minimum speed can be adjusted automatically based on relative humidity to compensate as humidity rises.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662209,1793206471,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":26,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},962090768658,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Temperature Controller  \nTC5-2V2SA  \nUSER'S MANUAL  \nM 890-00170  \nrev . 05  \nREV. 01  \nTABLE OF CONTENTS  \nPage  \nPRECAUTIONS .............................................................. 3  \nFEATURES ..................................................................... 4  \nLOCATION OF THE CONTROLS ................................... 6  \nController Status Leds ................................................... 7  \nInternal Switches ........................................................... 7  \nINSTALLATION .............................................................. 8  \nMounting Instructions ..................................................... 8  \nConnections .................................................................. 8  \nMotor Types .................................................................. 9  \nHeating/Cooling Option ................................................. 10  \nTemperature Probes ..................................................... 11  \nCHANGING THE PARAMETER SETTINGS .................. 14  \nUsing the Display .......................................................... 14  \nLocking the Parameters Settings .................................. 15  \nTEMPERATURE SETTINGS .......................................... 16  \nTemperature Units ......................................................... 16  \nViewing Temperatures .................................................. 16  \nTemperature Set Point .................................................. 19  \nTemperature Curve ....................................................... 20  \nVENTILATION SETTINGS .............................................. 24  \nCooling Operation ......................................................... 24  \nMinimum Ventilation Cycle ............................................ 26  \nHumidity Compensation ................................................ 28  \nMinimum Speed Curve .................................................. 31  \nDifferential Settings ....................................................... 37  \nDe-icing of Stage 2 Fans .............................................. 39  \nMist Cooling .................................................................. 41  \nHEATER SETTINGS ....................................................... 44  \nALARM SETTINGS ......................................................... 49  \nTEST MODE .................................................................... 50  \nTROUBLESHOOTING GUIDE ........................................ 51  \nTECHNICAL SPECIFICATIONS ..................................... 55  \nFACTORY SETTINGS .................................................... 56  \nGLOSSARY ..................................................................... 58  \n2 TC5-2V2SA.rev.05  \nPRECAUTIONS  \nWe strongly recommend installing supplementary natural ventilation as well as a back-up thermostat on at least one cooling stage (refer to the wiring diagram enclosed with this user's manual to connect the thermostat) .  \nAlthough fuses at the input and outputs of the controller protect its circuits in case of an overload or overvoltage, we recommend installing an additional protection device on the controller's supply circuit.  \nThe room temperature where the controller is located MUST ALWAYS REMAIN BETWEEN 32°F AND 104°F (0°C TO 40°C) .  \nTo avoid exposing the controller to harmful gases or excessive humidity, it is preferable to install it in a corridor.  \nDO NOT SPRAY WATER ON THE CONTROLLER  \nFOR CUSTOMER USE  \nEnter the serial number located on the  \nside of the controller below for future reference.  \nModel number: TC5-2V2SA Serial number:    \nTC5-2V2SA.rev.05 3  \nFEATURES  \nThe TC5-2V2SA is an electronic device used for environmental control in livestock buildings. It allows the user to maintain a specified target temperature by controlling the operation of ventilation and heating equipment. Two stages of variable speed fans can be connected to the controller, as well as two stages of either consta","cbCaitrLSBPEOLF6","https://ap.wps.com/l/cbCaitrLSBPEOLF6","pdf",647588,"English","# Precautions\n# Features\n# Location of the Controls\n## Controller Status Leds\n## Internal Switches\n# Installation\n## Mounting Instructions\n## Connections\n## Motor Types\n## Heating/Cooling Option\n## Temperature Probes\n# Changing the Parameter Settings\n## Using the Display\n## Locking the Parameters Settings\n# Temperature Settings\n## Temperature Units\n## Viewing Temperatures\n## Temperature Set Point\n## Temperature Curve\n# Ventilation Settings\n## Cooling Operation\n## Minimum Ventilation Cycle\n## Humidity Compensation\n## Minimum Speed Curve\n## Differential Settings\n## De-icing of Stage 2 Fans\n## Mist Cooling\n# Heater Settings\n# Alarm Settings\n# Test Mode\n# Troubleshooting Guide\n# Technical Specifications\n# Factory Settings\n# Glossary","[{\"question\":\"What is the purpose of the TC5-2V2SA temperature controller?\",\"answer\":\"It maintains a target temperature in livestock buildings by controlling ventilation and heating equipment, including variable-speed fans and optional mist cooling.\"},{\"question\":\"What key safety precautions does the manual emphasize?\",\"answer\":\"Install supplementary natural ventilation and a back-up thermostat for at least one cooling stage, use additional protection on the supply circuit, keep the controller location between 32°F and 104°F (0°C to 40°C), and do not spray water on the controller.\"},{\"question\":\"How does the controller manage ventilation and humidity?\",\"answer\":\"It supports temperature curve scheduling and minimum ventilation speed curves, and stage 1 minimum speed can be adjusted automatically based on relative humidity to compensate as humidity rises.\"}]","TC5-2V2SA - User's Manual - REV. 05 | PDF",151]