[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-466513-105":59,"doc-detail-466513-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","targeted-determination-of-residual-sex-hormones-in-cosmetics-using-magnetic-solid-phase-extraction-with-isotope-labeled-internal-standards","Targeted Determination of Residual Sex Hormones in Cosmetics Using Magnetic Solid-Phase Extraction with Isotope-Labeled Internal Standards","","Consumer cosmetics face safety risks from hazardous ingredients, notably residual sex hormones. This work develops and validates an analytical method to detect trace sex hormones in cosmetics using UHPLC-MS/MS combined with magnetic solid-phase extraction and isotope-labeled internal standards. Sample pretreatment, chromatographic separation, and mass spectrometric conditions were systematically optimized. Fe3O4@HLB magnetic materials enhanced purification and analyte enrichment, while isotope-labeled standards mitigated matrix effects and preparation losses, improving precision and accuracy. In fortified tests, recoveries were 71.7–116.2% with RSD 1.6–8.3%, and 116 cosmetic batches revealed progestins and estrogens in 10 samples.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/targeted-determination-of-residual-sex-hormones-in-cosmetics-using-magnetic-solid-phase-extraction-with-isotope-labeled-internal-standards/466513/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/targeted-determination-of-residual-sex-hormones-in-cosmetics-using-magnetic-solid-phase-extraction-with-isotope-labeled-internal-standards/466513.png","ImageObject",300,407,{"name":92,"@type":93},"Mabel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why is detecting residual sex hormones in cosmetics important?","Question",{"text":112,"@type":113},"Residual sex hormones are associated with potential health hazards, including risks to human reproductive health and carcinogenesis. Detecting trace levels is therefore crucial for cosmetic safety.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What analytical approach was developed in this study?",{"text":117,"@type":113},"The method combines UHPLC-MS/MS with magnetic solid-phase extraction (MSPE) using Fe3O4@HLB magnetic material and isotope-labeled internal standards to improve purification, enrichment, and measurement reliability.",{"name":119,"@type":110,"acceptedAnswer":120},"How was method performance evaluated?",{"text":121,"@type":113},"Performance was assessed using fortified samples at three levels, achieving recoveries of 71.7–116.2% and RSD values between 1.6% and 8.3%. The method was also applied to 116 cosmetic batches, detecting trace progestins and estrogens in 10 samples.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},466513,1791170906,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},7971474920318,"https://ap-avatar.wpscdn.com/avatar/74000ee537e6b0ca360?x-image-process=image/resize,m_fixed,w_180,h_180&k=1788430171632181674","Article  \nTargeted Determination of Residual Sex Hormones in Cosmetics Using Magnetic Solid-Phase Extraction with Isotope-Labeled Internal Standards by UHPLC-MS/MS  \nYalei Dong 1,†, Shuyan Sun 1,2,†, Yasen Qiao 1, Chunhui Yu 3, Haiyan Wang 1, * and Lei Sun 1, *  \nAcademic Editor: Victoria Samanidou  \nReceived: 21 November 2025  \nRevised: 18 December 2025  \nAccepted: 23 December 2025  \nPublished: 25 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 National Institutes for Food and Drug Control/NMPA Key Laboratory for Research and Evaluation of Cosmetics, Beijing 100050, China; [dongyalei@nifdc.org.cn](dongyalei@nifdc.org.cn) (Y.D.); [yan18531864610@163.com](yan18531864610@163.com) (S.S.); [qiaoyasen@126.com](qiaoyasen@126.com) (Y.Q.)  \n2 School of Traditional Chinese Pharmacy, NMPA Key Laboratory for Research and Evaluation for Cosmetics, China Pharmaceutical University, Nanjing 211198, China  \n3 Pureton Lab Equipment (Shanghai) Co., Ltd., Shanghai 201108, China; [13825165882@139.com](13825165882@139.com)  \n* Correspondence: [summerwhy163@163.com](summerwhy163@163.com) (H.W.); [dasunlei@sina.com](dasunlei@sina.com) (L.S.); Tel.: +86-010-67095060 (H.W.)† These authors contribute equally to this work.  \nAbstract  \nAs rapidly developing consumer products, cosmetics confront challenges regarding safety, especially hazardous ingredients, like sex hormones. Prolonged exposure to trace sex hormones in cosmetics can inflict immeasurable damage to human health. To accurately detect the trace amounts of sex hormones in cosmetics, a reliable method was developed and validated using ultra-high performance liquid chromatography–mass spectrometry (UHPLC-MS/MS) with magnetic solid-phase extraction (MSPE) and isotope-labeled internal standards (IL-ISs) . The conditions of sample pretreatment, chromatography, and mass parameters were systemically investigated. In the MSPE procedure, the commercial Fe3O4@HLB magnetic material was employed for sample pretreatment, which was beneficial for operation, as well as sample purification and analyte enrichment. The utilization of IL-ISs compensated for potential matrix effects and losses during sample preparation, thereby improving precision and accuracy. Based on the proposed MSPE technology, UHPLC-MS/MS can address the qualitative and quantitative analysis needs for target analytes in complex cosmetic matrices. At three fortification levels, recoveries were in the range of 71.7–116.2%, with a relative standard deviation (RSD) ranging from 1.6% to 8.3% . Furthermore, based on the method proposed here, a total of 116 batches of cosmetics were analyzed, and trace progestins and estrogens were discovered in 10 samples. The MSPE method, coupled with UHPLC-MS/MS using IL-ISs, was convenient, efficient, and feasible for detecting trace amounts of sex hormones in cosmetics. The method scored 0.66 (out of 1) on the AGREE metric, confirming its green profile. Based on the detected concentrations, a preliminary safety evaluation was performed to assess the potential health risks of residual progesterone in hair loss prevention cosmetics by calculating the margin of safety (MoS) .  \nKeywords: MSPE; UHPLC-MS/MS; sex hormones; cosmetics; progesterone; safety evaluation  \n1. Introduction  \nExogenous sex steroid hormones, exhibiting a strong affinity for hormone receptors and high disruption potencies in humans, have received increasing attention in recent years [1] . These hormones derive from both natural and synthetic sources. Natural hormones are normally excreted by humans and livestock, involving progestin (P),  \nestrone (E1), estradiol (E2), estriol (E3), and so on. Synthetic hormones are synthetic progestin or estrogen derivatives used in oral contraceptives and hormone replacement therapies, such as norgestrel (NG), ethynyl estradiol (EE2","cbCaia3uiydHSK6i","https://ap.wps.com/l/cbCaia3uiydHSK6i","pdf",830870,17,"English","# Introduction\n## Exogenous and endogenous sex hormones in health contexts\n## Challenges of detecting sex hormones in complex cosmetics\n## Existing analytical methods\n## Objective of the study","[{\"question\":\"Why is detecting residual sex hormones in cosmetics important?\",\"answer\":\"Residual sex hormones are associated with potential health hazards, including risks to human reproductive health and carcinogenesis. Detecting trace levels is therefore crucial for cosmetic safety.\"},{\"question\":\"What analytical approach was developed in this study?\",\"answer\":\"The method combines UHPLC-MS/MS with magnetic solid-phase extraction (MSPE) using Fe3O4@HLB magnetic material and isotope-labeled internal standards to improve purification, enrichment, and measurement reliability.\"},{\"question\":\"How was method performance evaluated?\",\"answer\":\"Performance was assessed using fortified samples at three levels, achieving recoveries of 71.7–116.2% and RSD values between 1.6% and 8.3%. The method was also applied to 116 cosmetic batches, detecting trace progestins and estrogens in 10 samples.\"}]","Targeted Determination of Residual Sex Hormones in Cosmetics Using Magnetic Solid-Phase Extraction with Isotope-Labeled Internal Standards | PDF",1790771390,43,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2c6a875f7ff3f0b9f36ed54e95cb1a23.webp",983,1390,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/867f7d9b0633b4af045bc063299b72ad.webp",982,1388,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/5f22c9e8a009591278573ea3ede950c8.webp",981,1387,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/f309004af4e1e19b8cc4cfac82c7e8bc.webp",980,1385]