[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-464284-105":59,"doc-detail-464284-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","tactile-sensor-based-body-center-of-pressure-estimation-system-using-supervised-deep-learning-models","Tactile Sensor-Based Body Center of Pressure Estimation System Using Supervised Deep Learning Models","","The center of pressure (CoP) serves as a key biomechanical indicator for evaluating balance and fall risk, yet force plates are costly and impractical for broad adoption. Low-cost options such as inertial units and pressure sensors face drift, sparse coverage, and directional performance imbalances. This work presents a tactile sensor-based CoP estimation system using deep learning, combining CNN/ResNet encoders for 2D spatial features with a Bi-LSTM for temporal dynamics. Using data from 23 healthy adults across four balance protocols, ResNet-Bi-LSTM achieved the best results under LOOCV, reducing the ML/AP NRMSE gap to 1.3% from 3.2–4.7%, supporting potential real-time gait and balance monitoring.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/tactile-sensor-based-body-center-of-pressure-estimation-system-using-supervised-deep-learning-models/464284/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/tactile-sensor-based-body-center-of-pressure-estimation-system-using-supervised-deep-learning-models/464284.png","ImageObject",300,407,{"name":92,"@type":93},"pixelkiddo","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-02","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",13,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"Why are force plates not ideal for widespread center of pressure (CoP) measurement?","Question",{"text":113,"@type":114},"Force plates are highly reliable but expensive and difficult to deploy due to installation constraints and limited mobility in home and some clinical settings.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does the proposed system estimate CoP from tactile sensor data?",{"text":118,"@type":114},"It uses deep learning where CNN/ResNet encoders extract 2D spatial features from pressure distribution images, followed by a Bi-LSTM to model temporal patterns.",{"name":120,"@type":111,"acceptedAnswer":121},"What model performed best and how was it evaluated?",{"text":122,"@type":114},"ResNet-Bi-LSTM with angular features achieved the best performance under leave-one-out cross-validation (LOOCV), evaluated using RMSE, NRMSE, and R2, and it reduced the ML/AP NRMSE difference to 1.3%.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},464284,1790845652,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},962090883892,"https://ap-avatar.wpscdn.com/avatar/e00115db34f3e0f11b?x-image-process=image/resize,m_fixed,w_180,h_180&k=1790152879550218658","Article  \nTactile Sensor-Based Body Center of Pressure Estimation System Using Supervised Deep Learning Models  \nJaehyeon Baik 1, Yunho Choi 2, Kyung-Joong Kim 3, Young Jin Park 4 and Hosu Lee 1,5, *  \nAcademic Editors: Wenbo Ding, Zhenyu Lu, Chenguang Yang, Bin Fang and Daolin Ma  \nReceived: 15 October 2025  \nRevised: 24 November 2025  \nAccepted: 12 December 2025  \nPublished: 2 January 2026  \nCopyright: © 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 Department of Control and Robot Engineering, Gyeongsang National University, Jinju 52828, Republic of Korea; [bjhme22@naver.com](bjhme22@naver.com)  \n2 Department of Electrical and Computer Engineering, University of Washington, Seattle, WA 98195, USA; [dbsh070@gmail.com](dbsh070@gmail.com)  \n3 Department of AI Convergence, College of Information and Computing, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea; [kjkim@gist.ac.kr](kjkim@gist.ac.kr)  \n4 School of Mechanical Engineering, Gyeongsang National University, Jinju 52828, Republic of Korea; [youngjin.park@gnu.ac.kr](youngjin.park@gnu.ac.kr)  \n5 Gyeongnam Aerospace & Defence Institute of Science and Technology, Gyeongsang National University, Jinju 52828, Republic of Korea  \n* Correspondence: [lakelee77@gnu.ac.kr](lakelee77@gnu.ac.kr)  \nAbstract  \nThe center of pressure (CoP) is a key biomechanical indicator for assessing balance and fall risk; however, force plates, the gold standard for CoP measurement, are costly and impractical for widespread use. Low-cost alternatives such as inertial units or pressure sensors are limited by drift, sparse sensor coverage, and directional performance imbalances, with previous supervised learning approaches reporting ML-AP NRMSE differences of 3.2–4.7% using 1D time-series models on sparse sensor arrays. Therefore, we propose a tactile sensor-based CoP estimation system using deep learning models that can extract 2D spatial features from each pressure distribution image with CNN/ResNet encoders followed by a Bi-LSTM for temporal patterns. Using data from 23 healthy adults performing four balance protocols, we compared ResNet-Bi-LSTM and CNN-Bi-LSTM with baseline CNN-LSTM and Bi-LSTM models used in previous studies. Model performance was validated using leave-one-out cross-validation (LOOCV) and evaluated with RMSE, NRMSE, and R2. The ResNet-Bi-LSTM with angular features achieved the best performance, with RMSE values of 18.63 ± 4.57 mm in the mediolateral (ML) direction and 17.65 ± 3.48 mm in the anteroposterior (AP) direction, while reducing the ML/AP NRMSE difference to 1.3% compared to 3.2–4.7% in previous studies. Under dynamic protocols, ResNet-Bi-LSTM maintained the lowest RMSE across models. These findings suggest that tactile sensorbased systems may provide a cost-effective alternative to force plates and hold potential for applications in gait analysis and real-time balance monitoring. Future work will validate clinical applicability in patient populations and explore real-time implementation.  \nKeywords: balance; center of pressure; estimation; tactile sensor; supervised learning; ResNet-Bi-LSTM; CNN-Bi-LSTM  \n1. Introduction  \nAs the aging population rapidly grows worldwide, the fall problem of the elderly is emerging as a serious public health issue. According to the World Health Organization (WHO), approximately 16% of the world’s population is expected to be over the age of 60 by 2030, resulting in a rapid increase in social burdens, including health problems and  \nincreased medical expenses caused by falls [1–3] . Falls are a major cause of poor quality of life, as well as fractures, long-term disabilities, and mobility restrictions, and the importance of balance assessment to prevent them is gradually increasing [4] .  \nIn evaluating balance state, the center of pressure (CoP) is widely used to qua","cbCaiu5NJWqporeR","https://ap.wps.com/l/cbCaiu5NJWqporeR","pdf",4430792,23,"English","# Abstract\n# Introduction","[{\"question\":\"Why are force plates not ideal for widespread center of pressure (CoP) measurement?\",\"answer\":\"Force plates are highly reliable but expensive and difficult to deploy due to installation constraints and limited mobility in home and some clinical settings.\"},{\"question\":\"How does the proposed system estimate CoP from tactile sensor data?\",\"answer\":\"It uses deep learning where CNN/ResNet encoders extract 2D spatial features from pressure distribution images, followed by a Bi-LSTM to model temporal patterns.\"},{\"question\":\"What model performed best and how was it evaluated?\",\"answer\":\"ResNet-Bi-LSTM with angular features achieved the best performance under leave-one-out cross-validation (LOOCV), evaluated using RMSE, NRMSE, and R2, and it reduced the ML/AP NRMSE difference to 1.3%.\"}]","Tactile Sensor-Based Body Center of Pressure Estimation System Using Supervised Deep Learning Models | PDF",1790767980,58,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3bc9435606a2f07f5bb374e2de4903a8.webp",983,1390,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/0e6f827f22ae29f5a378bb032d911084.webp",982,1388,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2bc00c336f7852ebd0ac638507240188.webp",981,1387,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/35f47094f23974ff6cc92307d89ec533.webp",980,1385]